New Cloakroom Waste Piping query
Hi
Currently building a new ground floor cloaks with WC and basin - drain run is in, connected and approved by BCO - internally all there is is the end of the 110mm pipe I want to connect a WC and a basin to this pipe - what's the best way? so far I'm considering a) building a "mini internal stack" with durgo, using a branch "on it's back" and connecting the basin on the vertical, finishing witha durgo; and b) plumbing WC straight to the existing 110mm pipe and "strapping" on the basin waste direct to the 110mm with an anti-vac fitting to preserve the basin trap... Is either of these the best thing to do? or something else I haven't thought of? TIA Jim |
#2
Posted to uk.d-i-y
|
|||
|
|||
New Cloakroom Waste Piping query
jim wrote:
Hi Currently building a new ground floor cloaks with WC and basin - drain run is in, connected and approved by BCO - internally all there is is the end of the 110mm pipe I want to connect a WC and a basin to this pipe - what's the best way? so far I'm considering a) building a "mini internal stack" with durgo, using a branch "on it's back" and connecting the basin on the vertical, finishing witha durgo; and b) plumbing WC straight to the existing 110mm pipe and "strapping" on the basin waste direct to the 110mm with an anti-vac fitting to preserve the basin trap... Is either of these the best thing to do? or something else I haven't thought of? TIA Jim I would always consider use of a HepVO trap. Might choose against in the end - but definitely need to consider. -- Rod Hypothyroidism is a seriously debilitating condition with an insidious onset. Although common it frequently goes undiagnosed. www.thyromind.info www.thyroiduk.org www.altsupportthyroid.org |
#3
Posted to uk.d-i-y
|
|||
|
|||
New Cloakroom Waste Piping query
jim wrote:
Is either of these the best thing to do? or something else I haven't thought of? You can also get WC connectors that include a waste pipe connection. -- Cheers, John. /================================================== ===============\ | Internode Ltd - http://www.internode.co.uk | |-----------------------------------------------------------------| | John Rumm - john(at)internode(dot)co(dot)uk | \================================================= ================/ |
#4
Posted to uk.d-i-y
|
|||
|
|||
New Cloakroom Waste Piping query
On 28 Oct, 01:06, John Rumm wrote:
jim wrote: Is either of these the best thing to do? or something else I haven't thought of? You can also get WC connectors that include a waste pipe connection. -- Cheers, John. Hi John Yes I've seen one sort of these (Wickes for eg), where the extra waste connector joins on the "other side" of the elbow of the WC connector - however in the current plan the basin waste would need to connect *after* the WC. Are there other variations on these that may suit my situation better? Should a BCO be OK with a strap boss direct to the horizontal 110mm waste pipe (betwixt WC and wall) and a HepVO on the basin waste run? cheers Jim |
#5
Posted to uk.d-i-y
|
|||
|
|||
New Cloakroom Waste Piping query
On 28 Oct, 01:06, John Rumm wrote:
jim wrote: Is either of these the best thing to do? or something else I haven't thought of? You can also get WC connectors that include a waste pipe connection. -- Cheers, John. Hi John Yes I've seen one sort of these (Wickes for eg), where the extra waste connector joins on the "other side" of the elbow of the WC connector - however in the current plan the basin waste would need to connect *after* the WC. Are there other variations on these that may suit my situation better? Should a BCO be OK with a strap boss direct to the horizontal 110mm waste pipe (betwixt WC and wall) and a HepVO on the basin waste run? cheers Jim |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Can I get a cloakroom into 104cmx80cm space? | UK diy | |||
Cloakroom Basin Installation... | UK diy | |||
Moving a toilet-query on new waste pipe lay-out | UK diy | |||
Electrical and ventilation questions for cloakroom | UK diy | |||
Electrical installation in a cloakroom | UK diy |