I simply want to move a Radiator 3 foot to the left so its sitting
under a window . But i will have to lengthen pipes to do this , that
is not a problem . My question is i have a combi bolier , do i drain
it down , what do i turn off . Basically what should i do . I had no
problems with my old back boiler , but the combi is new to me . Any
help please .

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 69
Default Adding radiator


"Bluesplayer" wrote in message
oups.com...
I simply want to move a Radiator 3 foot to the left so its sitting
under a window . But i will have to lengthen pipes to do this , that
is not a problem . My question is i have a combi bolier , do i drain
it down , what do i turn off . Basically what should i do . I had no
problems with my old back boiler , but the combi is new to me . Any
help please .


Firstly, I am not a plumber.....

....however if you have worked with other central heating systems then this
should not be difficult.

You obviously have to turn the boiler off, but then you just have a sealed,
pressurised system instead of a vented one with a small header tank.

Drain down the radiators as normal from the lowest point - you may have to
loosen off a bleed screw from an upstairs radiator to get the water out. Be
prepared for a lot of pressure when you start to drain.

Move your radiator, close all bleed screws etc..

You will, of course, have to add chemicals to the water to protect the
system, but this should be relatively easy with a drained system - look at
the FAQ.

Follow the instructions for adding cold water to the heating circuit (on my
boiler there is a tap from the mains built in to the base of the boiler) and
pressurise to the recommended mark (for cold), bleed all the radiators and
away you go!

I don't know if you will have to bleed the boiler - mine is a recent one and
has a self-bleed programme when it restarts after power down.

The professionals should be along shortly to fill in any gaps :-)

HTH

Dave R



  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 171
Default Adding radiator


"Bluesplayer" wrote in message
oups.com...
I simply want to move a Radiator 3 foot to the left so its sitting
under a window . But i will have to lengthen pipes to do this , that
is not a problem . My question is i have a combi bolier , do i drain
it down , what do i turn off . Basically what should i do . I had no
problems with my old back boiler , but the combi is new to me . Any
help please .

No problem in draining down a combi system. Just switch off the power to the
boiler & drain down in the usual way from the lowest drain cock, but let
some air into system by opening a radiator vent or two at a higher level.
If you are going to use compression fittings to make your joints then the
water in the system should hold back on a vacuum by opening the rad valve
(after removing the rad) and catching the small amount of water that comes
out before the vacuum takes hold. Do not open any rad vents when doing it
this way.


  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 97
Default Adding radiator

On Sun, 14 Oct 2007 13:03:52 +0100, "David W.E. Roberts"
wrote:


"Bluesplayer" wrote in message
roups.com...
I simply want to move a Radiator 3 foot to the left so its sitting
under a window . But i will have to lengthen pipes to do this , that
is not a problem . My question is i have a combi bolier , do i drain
it down , what do i turn off . Basically what should i do . I had no
problems with my old back boiler , but the combi is new to me . Any
help please .


Firstly, I am not a plumber.....

...however if you have worked with other central heating systems then this
should not be difficult.

You obviously have to turn the boiler off, but then you just have a sealed,
pressurised system instead of a vented one with a small header tank.

Drain down the radiators as normal from the lowest point - you may have to
loosen off a bleed screw from an upstairs radiator to get the water out. Be
prepared for a lot of pressure when you start to drain.

Move your radiator, close all bleed screws etc..

You will, of course, have to add chemicals to the water to protect the
system, but this should be relatively easy with a drained system - look at
the FAQ.



very easy if the installer has put in an additive filling point as
mine did .It's next to the boiler .

Follow the instructions for adding cold water to the heating circuit (on my
boiler there is a tap from the mains built in to the base of the boiler) and
pressurise to the recommended mark (for cold), bleed all the radiators and
away you go!


My installer fitted two taps adjacent to the boiler .One to serve the
cold water feed to the boiler and another to drain the system down .

  #5   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,231
Default Adding radiator

On Sun, 14 Oct 2007 01:55:59 -0700, Bluesplayer wrote:

I simply want to move a Radiator 3 foot to the left so its sitting
under a window . But i will have to lengthen pipes to do this , that
is not a problem . My question is i have a combi bolier , do i drain
it down , what do i turn off . Basically what should i do . I had no
problems with my old back boiler , but the combi is new to me . Any
help please .


See Sealed CH FAQ.


--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Adding additional Radiator Martin Tunn UK diy 3 January 4th 07 05:18 PM
Adding a radiator Allan Gamble UK diy 2 September 12th 06 08:14 AM
Adding a 2nd Radiator in the Living Room Kevin UK diy 1 June 1st 06 11:08 PM
Adding a cast iron radiator TomD Home Repair 5 November 17th 05 03:51 AM
Adding Radiator using 8mm Microbore Darren Forward UK diy 1 December 7th 04 08:46 PM


All times are GMT +1. The time now is 05:31 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"