  #1   Report Post  
Posted to alt.home.repair
TomD
 
Posts: n/a
Default Adding a cast iron radiator

I have recently completed finishing my unfinished attic (almost). The
attic had plaster walls and a wood floor installed, which seemed to me
that they builder had intentions of finishing it. The house was built
in 1850. There are also two pipes for a radiator run into the attic
(cut through a shaped plank for that radiator to sit on). I want to
start looking for a salvaged radiator but I want to make sure that I
get the correct size. The pipes are about 43" apart. Most of the
radiators that I see online are measured in height, not width. Any
help in selecting a radiator would be greatl appreciated.

Thanks,
Tom

  #2   Report Post  
Posted to alt.home.repair
Edwin Pawlowski
 
Posts: n/a
Default Adding a cast iron radiator


"TomD" wrote in message
oups.com...
I have recently completed finishing my unfinished attic (almost). The
attic had plaster walls and a wood floor installed, which seemed to me
that they builder had intentions of finishing it. The house was built
in 1850. There are also two pipes for a radiator run into the attic
(cut through a shaped plank for that radiator to sit on). I want to
start looking for a salvaged radiator but I want to make sure that I
get the correct size. The pipes are about 43" apart. Most of the
radiators that I see online are measured in height, not width. Any
help in selecting a radiator would be greatl appreciated.


To get the correct size, you need to know how much heat you need. Here is a
good place to start
http://www.colonialsupply.com/resources/radiator.htm

As long as the radiator fits between the pipes it is easy enough to plumb.
If it does not, it can still be plumbed, just takes more time and elbows.


  #3   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Adding a cast iron radiator


Edwin Pawlowski wrote:
"TomD" wrote in message
oups.com...
I have recently completed finishing my unfinished attic (almost). The
attic had plaster walls and a wood floor installed, which seemed to me
that they builder had intentions of finishing it. The house was built
in 1850. There are also two pipes for a radiator run into the attic
(cut through a shaped plank for that radiator to sit on). I want to
start looking for a salvaged radiator but I want to make sure that I
get the correct size. The pipes are about 43" apart. Most of the
radiators that I see online are measured in height, not width. Any
help in selecting a radiator would be greatl appreciated.


To get the correct size, you need to know how much heat you need. Here is a
good place to start
http://www.colonialsupply.com/resources/radiator.htm

As long as the radiator fits between the pipes it is easy enough to plumb.
If it does not, it can still be plumbed, just takes more time and elbows.


Greetings,

Ed's advice is good but in your case the right size may in fact the be
wrong size. If your house has oversized radiators everywhere else due
to added insulation, new windows, etc. and you put the "right size"
radiator in one room that room may prove to be too cold. Consider
oversizing your radiator by the same amount your other radiators have
been oversized for consistent house heating.

Hope this helps,
William

  #4   Report Post  
Posted to alt.home.repair
TomD
 
Posts: n/a
Default Adding a cast iron radiator

Thanks guys...Is there an easy way to check and make sure that there
are no leaks in the salvaged radiator?

  #5   Report Post  
Posted to alt.home.repair
 
Posts: n/a
Default Adding a cast iron radiator


TomD wrote:
Thanks guys...Is there an easy way to check and make sure that there
are no leaks in the salvaged radiator?


a) Bring a cap/plug to screw into one side of the radiator.
b) Bring an air tank connected to a shutoff valve connected to a
pressure valve to screw into the other side of the radiator.
c) Open the valve to pressurize the radiator (don't overpressurize).
d) Close the valve and use the pressure guage to see if the radiator
holds.

.....

or ask for a 48 hour return period in case of leak.

Hope this helps,
William



  #6   Report Post  
Posted to alt.home.repair
Edwin Pawlowski
 
Posts: n/a
Default Adding a cast iron radiator

Thanks guys...Is there an easy way to check and make sure that there
are no leaks in the salvaged radiator?


a) Bring a cap/plug to screw into one side of the radiator.
b) Bring an air tank connected to a shutoff valve connected to a
pressure valve to screw into the other side of the radiator.
c) Open the valve to pressurize the radiator (don't overpressurize).
d) Close the valve and use the pressure guage to see if the radiator
holds.


You can also put the radiator in a pool and pressurize it and look for
bubbles. Heavy to handle though.

You can also fill it with water and then pressurize it and look for leaks.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
cast iron hinges [email protected] UK diy 4 July 22nd 05 11:27 PM
Experience with Cast Iron wheels vs Cast Aluminum Brad Woodworking 3 July 19th 05 11:52 PM
Wrought Iron, Cast Alum and Cast Iron Decorative welding Roy Metalworking 7 April 30th 04 08:52 AM
Cutting a 3" hole in cast-iron waste stack [email protected] Home Repair 14 April 22nd 04 12:42 PM
Cast Iron sewer -- Is it a hazard? Steve Smith Home Ownership 5 September 8th 03 11:06 PM


All times are GMT +1. The time now is 07:53 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"