My plans require an inspection chamber at the junction of 2 soil
pipes. The pipes will need to meet at around 10 degrees it both are
straight. Since the chamber is required at bends, you may surmise that
they have to be straight. So how do you join them at 10 degrees ? You
can't bend at the inlet, since a bend is not allowed. Since the
chamber bases seem to have 45 degree and 90 degree inlets, how should
these connections be made ?
TIA,
Simon.

  #2   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 261
Default Drainage - soil pipes / inspection chamber

On Sep 19, 3:45 pm, sm_jamieson wrote:
My plans require an inspection chamber at the junction of 2 soil
pipes. The pipes will need to meet at around 10 degrees it both are
straight. Since the chamber is required at bends, you may surmise that
they have to be straight. So how do you join them at 10 degrees ? You
can't bend at the inlet, since a bend is not allowed. Since the
chamber bases seem to have 45 degree and 90 degree inlets, how should
these connections be made ?
TIA,
Simon.


Bends are allowed. 45 degree or less are better for rodding purposes,
but long 90 degree bends are OK. One 45 degree would work in this
case.

A

  #3   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 1,026
Default Drainage - soil pipes / inspection chamber

On Sep 19, 6:01 pm, "
wrote:
On Sep 19, 3:45 pm, sm_jamieson wrote:

My plans require an inspection chamber at the junction of 2 soil
pipes. The pipes will need to meet at around 10 degrees it both are
straight. Since the chamber is required at bends, you may surmise that
they have to be straight. So how do you join them at 10 degrees ? You
can't bend at the inlet, since a bend is not allowed. Since the
chamber bases seem to have 45 degree and 90 degree inlets, how should
these connections be made ?
TIA,
Simon.


Bends are allowed. 45 degree or less are better for rodding purposes,
but long 90 degree bends are OK. One 45 degree would work in this
case.


By my calculation, you only need a 35 degree bend (there's already a
10 degree difference between the pipes). Depending on how fixed the
routes of the soil pipes are, the OP might be able to introduce a ~20
degree curve into both pipes so that they join at 45 degrees.

  #4   Report Post  
Posted to uk.d-i-y
external usenet poster
 
Posts: 2,688
Default Drainage - soil pipes / inspection chamber

On 20 Sep, 11:28, Martin Bonner wrote:
On Sep 19, 6:01 pm, "







wrote:
On Sep 19, 3:45 pm, sm_jamieson wrote:


My plans require an inspection chamber at the junction of 2 soil
pipes. The pipes will need to meet at around 10 degrees it both are
straight. Since the chamber is required at bends, you may surmise that
they have to be straight. So how do you join them at 10 degrees ? You
can't bend at the inlet, since a bend is not allowed. Since the
chamber bases seem to have 45 degree and 90 degree inlets, how should
these connections be made ?
TIA,
Simon.


Bends are allowed. 45 degree or less are better for rodding purposes,
but long 90 degree bends are OK. One 45 degree would work in this
case.


By my calculation, you only need a 35 degree bend (there's already a
10 degree difference between the pipes). Depending on how fixed the
routes of the soil pipes are, the OP might be able to introduce a ~20
degree curve into both pipes so that they join at 45 degrees.


Thanks for the advice - I guess I'll just chat about it with the BCO
and
see what he lets me have.
Simon.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
double seal inspection chamber / damp membrane sm_jamieson UK diy 0 May 18th 07 10:46 AM
shattered broken inspection chamber cover - why? [email protected] UK diy 11 January 6th 07 12:35 PM
Storm water inspection chamber? Tony Halmarack UK diy 2 August 3rd 04 02:20 PM
New inspection chamber... in the lounge?!! Lobster UK diy 17 November 15th 03 09:24 AM
Soil pipes and inspection chambers Mike Richardson UK diy 7 October 21st 03 02:22 PM


All times are GMT +1. The time now is 09:27 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"