Dimmer switch wattage
I've just replaced a light fitting that now has seven 60w bulbs in rather
than the one 100w - my dimmer switch is rated 250w - I assume as the lights are presumably wired in parallel this is ok - or should I look for a higher loaded dimmer switch? FWIW it works fine making no noise to suggest it's overloaded. TIA Buzby |
#2
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
Buzby wrote:
I've just replaced a light fitting that now has seven 60w bulbs in rather than the one 100w - my dimmer switch is rated 250w Err, 7 x 60w = 420w, so it *is* overloaded it works fine making no noise to suggest it's overloaded. wait for the noise of the fire service's sirens ... |
#3
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
Andy Burns wrote:
Buzby wrote: I've just replaced a light fitting that now has seven 60w bulbs in rather than the one 100w - my dimmer switch is rated 250w Err, 7 x 60w = 420w, so it *is* overloaded it works fine making no noise to suggest it's overloaded. wait for the noise of the fire service's sirens ... 420w, he must have a big house! Either that or its one of those strange people that dim their 420w to give out the light of 100w instead of replacing the 60s with 25s. If you dim bulbs they still consume most of their power rating, so using a dimmer with this will cost you silly money, plus heat your house up all summer. As an example, a 500w bulb dimmed to the output of a 40watter eats 300w. If you had 100w there before, you're unlikely to need more than 250w. NT |
#4
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
On Tue, 20 Jun 2006 09:04:24 +0100, Buzby wrote:
I've just replaced a light fitting that now has seven 60w bulbs in rather than the one 100w - my dimmer switch is rated 250w - I assume as the lights are presumably wired in parallel this is ok Simple maths. What is the total load now? 7 * 60 = 420W Is this total load greater than the rating of your dimmer switch (250W), yes, therfore it is is overloaded. It may well work but will get hotter than designed and either fail early, become a fire hazard, so hot as to burn someone who touches it or all three. -- Cheers Dave. pam is missing e-mail |
#5
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
"Dave Liquorice" wrote in message ll.com... On Tue, 20 Jun 2006 09:04:24 +0100, Buzby wrote: I've just replaced a light fitting that now has seven 60w bulbs in rather than the one 100w - my dimmer switch is rated 250w - I assume as the lights are presumably wired in parallel this is ok Simple maths. What is the total load now? 7 * 60 = 420W Is this total load greater than the rating of your dimmer switch (250W), yes, therfore it is is overloaded. It may well work but will get hotter than designed and either fail early, become a fire hazard, so hot as to burn someone who touches it or all three. Thanks for that. Having actually looked at the bulbs, as opposed to being told what they are by SWMBO, they are in fact 25W. On the upside I've learned something new today. Cheers Buzby |
#6
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
Christian McArdle wrote:
I've just replaced a light fitting that now has seven 60w bulbs in rather than the one 100w Have you heard of global warming? Hint: 420W of bulbs in your lounge is as obscene as a Range Rover Sport in Chelsea. my dimmer switch is rated 250w - I assume as the lights are presumably wired in parallel this is ok Of course it isn't. Did you actually go to school? Christian. Ive got a total of 500W in mine and its still not enough for 30 sq meters... |
#7
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
Ive got a total of 500W in mine and its still not enough for 30 sq
meters... My lounge uses 22W and is too bright. It is much smaller, though. Most of my rooms get by on 15W, except the kitchen, which has a gas guzzling 116W, but is very well lit under the cupboards (4x16W + 30W). Christian. |
#8
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
The message
from "Christian McArdle" contains these words: Hint: 420W of bulbs in your lounge is as obscene as a Range Rover Sport in Chelsea. I have nearly that in my living room. The difference is that I don't have them all on at the same time! Generally there's only a couple of 20W reading lamps and a couple of 40W uplighters. -- Skipweasel Pay no attention to that man behind the curtain. |
#9
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
Buzby wrote:
Having actually looked at the bulbs, as opposed to being told what they are by SWMBO, they are in fact 25W. Ok, so 175W won't overload your dimmer, but others have pointed out if you run them dimmed, you'll likely still be paying more than for having a single larger bulb at full brightness. That said, the only room of the house where I don't have CFL lamps is the lounge where I have a dimmer+filament, the only place I find I need it adjustable ... |
#10
Posted to uk.d-i-y
|
|||
|
|||
Dimmer switch wattage
In article ,
Christian McArdle wrote: I've just replaced a light fitting that now has seven 60w bulbs in rather than the one 100w Have you heard of global warming? Hint: 420W of bulbs in your lounge is as obscene as a Range Rover Sport in Chelsea. 1465 watts worth in mine. On eight circuits. But rarely all on together. -- *Can vegetarians eat animal crackers? Dave Plowman London SW To e-mail, change noise into sound. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Singing light bulb on dimmer switch | Home Repair | |||
Low voltage lighting and extractor fan off dimmer switch? | UK diy | |||
3 way switch disaster (long but interesting) | Home Repair | |||
adding dimmer switch to old wiring | Home Repair | |||
Strange behavior of Lutron dimmer switch | Home Repair |