I just want to check with the Brains that my thinking is correct.

The boiler has four connections for external expansions, and one of
these is a spare.

The three remaining connections are shown as Ns, Ls and Lr

The diagram of a mechanical stat with heater show the Ns as "neutral"
and going to one end of the heater.
The Ls is "live" and goes to the other end of the heater and contains
an open switch symbol in line.
The Lr line is "Switched Live" ang goes to another terminal in the
stat.

The usual link is across the Ls and Lr connections.

The receiver has three connections on it and these are marked
"Live", "Output" and "Neutral"

So looking at the two,

Ns = Neutral

Ls = Live

Lr = Output????

HELP???

  #2   Report Post  
Posted to uk.d-i-y
EricP
 
Posts: n/a
Default Remote programmer/Thermostat connections Help

PS connecting it up.

I do not have 2 red 1 black cable.

Use 1 amp T2E with the earth slieved red?

Cheers

  #3   Report Post  
Posted to uk.d-i-y
Geronimo W. Christ Esq
 
Posts: n/a
Default Remote programmer/Thermostat connections Help

EricP wrote:
I just want to check with the Brains that my thinking is correct.

The boiler has four connections for external expansions, and one of
these is a spare.


Make and model of boiler, and of programmer ?
  #4   Report Post  
Posted to uk.d-i-y
John White
 
Posts: n/a
Default Remote programmer/Thermostat connections Help

EricP wrote:

PS connecting it up.

I do not have 2 red 1 black cable.

Use 1 amp T2E with the earth slieved red?


NO definitely not. The uninsulated wire in twin & earth must only be
used for the earth.

The correct cable to use would be 1.0mm three core and earth.

Old colours - Red - live, Blue - neutral, Yellow - switched live.
New colours - Brown - live, grey - neutral, Black - switched live.

Don't forget to get your "Part P" permission first :-)

John
--
John White,
Electrical Contractor
  #5   Report Post  
Posted to uk.d-i-y
EricP
 
Posts: n/a
Default Remote programmer/Thermostat connections Help

On Sun, 19 Mar 2006 21:19:46 +0000, John White
wrote:

EricP wrote:

PS connecting it up.

I do not have 2 red 1 black cable.

Use 1 amp T2E with the earth slieved red?


NO definitely not. The uninsulated wire in twin & earth must only be
used for the earth.

The correct cable to use would be 1.0mm three core and earth.

Old colours - Red - live, Blue - neutral, Yellow - switched live.
New colours - Brown - live, grey - neutral, Black - switched live.

Don't forget to get your "Part P" permission first :-)

John


Thanks for that John. I am now considering suicide. )

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Best Universal Remote? [email protected] Electronics Repair 13 January 28th 06 05:21 AM
Broken remote control for Encon ceiling fan Haymish UK diy 0 December 10th 05 06:48 PM
remote control for welder ESAB DTD250 AC/DC; connections? [email protected] Electronics Repair 0 December 2nd 05 03:28 AM
Sears Craftsman Garage Door Opener Remote Control FYI SpongeBob SquarePants Rules! Home Repair 0 March 22nd 04 03:41 AM
TV Remote Control rubber pad(UR50CT1071) used in remote control for Panasonic TV Model TX-29GF10X Steve Electronics Repair 4 November 1st 03 02:27 PM


All times are GMT +1. The time now is 07:43 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"