Glowworm Ultimate - no hot water
I have a 6 year old Glowworm Ultimate (not sure which model), its been
fine, today no hot water, but the radiators are fine. When I turn up the central heating thermostat I see/hear the boiler light, but when I run the hot water nothing, just cold water. The control set by the boiler (honeywell) appears ok, pushing the boost or putting the HW onto 24hr doesnt alter anything. My thinking was that their must be some sort of pressure switch/ thermostat combination - but boilers are not something I have tackled before. Any help/advise welcome |
#2
Posted to uk.d-i-y
|
|||
|
|||
Glowworm Ultimate - no hot water
piv wrote:
I have a 6 year old Glowworm Ultimate (not sure which model), its been fine, today no hot water, but the radiators are fine. When I turn up the central heating thermostat I see/hear the boiler light, but when I run the hot water nothing, just cold water. The control set by the boiler (honeywell) appears ok, pushing the boost or putting the HW onto 24hr doesnt alter anything. My thinking was that their must be some sort of pressure switch/ thermostat combination - but boilers are not something I have tackled before. Any help/advise welcome divertor valve stuck or broken ? -- Stop The Badger Cull - Respond by the 10th March http://www.stopthecull.info/emaildefra.php |
#3
Posted to uk.d-i-y
|
|||
|
|||
Glowworm Ultimate - no hot water
In message .com, piv
writes I have a 6 year old Glowworm Ultimate (not sure which model), its been fine, today no hot water, but the radiators are fine. When I turn up the central heating thermostat I see/hear the boiler light, but when I run the hot water nothing, just cold water. The control set by the boiler (honeywell) appears ok, pushing the boost or putting the HW onto 24hr doesnt alter anything. My thinking was that their must be some sort of pressure switch/ thermostat combination - but boilers are not something I have tackled before. Any help/advise welcome Probably the diverter valve motor died Do you know what and where this is ? -- geoff |