I'm having an issue with my Ariston Eurocombi A23. Occasionally when
using the shower, the hot water stops coming through after about 5
minutes. When looking at the boiler when this happens, the burners
stop burning, yet the boiler still seems to be On, i.e. the extractor
fan is on etc. When the shower is turned off, the boiler shuts down as
normal. After a minute or two when the shower is restarted, hot water
flows again, until again after about 5 mins the burners stop.

Before I get a CORGI in, does anyone have an idea about what could be
causing this? Is it likely to be something relatively simple, or am I
talking megabucks to fix?

Thanks.

Paul

  #2   Report Post  
Posted to uk.d-i-y
Sponix
 
Posts: n/a
Default Combi boiler keeps cutting out

On 15 Feb 2006 04:35:09 -0800, "Pacman"
wrote:

I'm having an issue with my Ariston Eurocombi A23. Occasionally when
using the shower, the hot water stops coming through after about 5
minutes.


What happens if you run the hot tap? Does it still cut out?

sponix
  #3   Report Post  
Posted to uk.d-i-y
IAN
 
Posts: n/a
Default Combi boiler keeps cutting out

Its likely to be the diverter valve


"Pacman" wrote in message
oups.com...
I'm having an issue with my Ariston Eurocombi A23. Occasionally when
using the shower, the hot water stops coming through after about 5
minutes. When looking at the boiler when this happens, the burners
stop burning, yet the boiler still seems to be On, i.e. the extractor
fan is on etc. When the shower is turned off, the boiler shuts down as
normal. After a minute or two when the shower is restarted, hot water
flows again, until again after about 5 mins the burners stop.

Before I get a CORGI in, does anyone have an idea about what could be
causing this? Is it likely to be something relatively simple, or am I
talking megabucks to fix?

Thanks.

Paul



  #4   Report Post  
Posted to uk.d-i-y
Pacman
 
Posts: n/a
Default Combi boiler keeps cutting out


Sponix wrote:


What happens if you run the hot tap? Does it still cut out?


Normal use, it doesnt cut out. However hot tap is never on for more
than a minute or 2 whilst a sink is filled etc.

Paul

  #5   Report Post  
Posted to uk.d-i-y
Pacman
 
Posts: n/a
Default Combi boiler keeps cutting out


IAN wrote:
Its likely to be the diverter valve


So what does that do? Is it an expensive, big job?

Paul



  #6   Report Post  
Posted to uk.d-i-y
Pacman
 
Posts: n/a
Default Combi boiler keeps cutting out


"Ed Sirett" wrote in message
news

A scaled up secondary heat exchanger is centre frame for this fault,
especially if the burner starts again after 30 seconds or so.

Burner doesnt start up, not without stopping the shower and starting it
again. It doesnt start up on its own.

Paul


  #7   Report Post  
Posted to uk.d-i-y
Ed Sirett
 
Posts: n/a
Default Combi boiler keeps cutting out

On Thu, 16 Feb 2006 08:53:01 +0000, Pacman wrote:


"Ed Sirett" wrote in message
news

A scaled up secondary heat exchanger is centre frame for this fault,
especially if the burner starts again after 30 seconds or so.

Burner doesnt start up, not without stopping the shower and starting it
again. It doesnt start up on its own.


Um... some problem with the water flow detector may be?

Assuming the DHW flow leads to some sort of micro switch I would try to
monitor it's output. I'd choose this test since it's not too difficult
and it will split the problem into two completely different approaches
from then on.



--
Ed Sirett - Property maintainer and registered gas fitter.
The FAQ for uk.diy is at http://www.diyfaq.org.uk
Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html
Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html
Choosing a Boiler FAQ http://www.makewrite.demon.co.uk/BoilerChoice.html


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Condensing Boiler News RedOnRed UK diy 0 April 9th 05 05:37 PM
new combi experience report Fred UK diy 12 December 5th 04 09:11 PM
Heat banks (again!) Dave UK diy 148 September 6th 04 08:45 PM
Water flow rate problem and Combi boiler Andrew Beck UK diy 15 September 3rd 04 11:00 PM
Combi Boiler Choice, please help! Andy UK diy 8 June 26th 04 11:08 PM


All times are GMT +1. The time now is 11:00 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"