Baxi Bermuda Inset 2 50/4E back boiler lockout
I have an intermittent problem with a Baxi Bermuda Inset 2 50/4E back
boiler. The igniter starts and the pilot light comes on but the boiler doesn't always light, the lockout light coming on after about 30 sec. During this 30 sec period the pilot light is on and the igniter is still sparking . Resetting the boiler by switching odd and back on again resolves the problem - until the next time !! Should I suspect the PCB or something else ? Any help appreciated. Brian |
#2
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda Inset 2 50/4E back boiler lockout
"Brian" wrote in message
oups.com... I have an intermittent problem with a Baxi Bermuda Inset 2 50/4E back boiler. The igniter starts and the pilot light comes on but the boiler doesn't always light, the lockout light coming on after about 30 sec. During this 30 sec period the pilot light is on and the igniter is still sparking . Resetting the boiler by switching odd and back on again resolves the problem - until the next time !! Should I suspect the PCB or something else ? Had this issue with drafts, bending the flame slightly causing the CO flame sensor to trigger the lockout. Not always on windy days either. Cured, in my case, by better draft sealing around the back hearth and a baffle plate being fixed by the fitter near the flame. I think air was being drawn in as the boiler ignited bending the flame. The fitter temporarily fitted some aluminium foil baffles to experiment as the boiler would not fault when open and taken apart of course. Removed foil and fitted a plate once he got it working 100%. This fixed it for years afterwards. |
#3
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda Inset 2 50/4E back boiler lockout
Thanks for that, worth a look, although the boiler has been working
fine for about 2 years with no problems. |
#4
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda Inset 2 50/4E back boiler lockout
On 2006-01-23, Ian_m wrote:
"Brian" wrote in message oups.com... I have an intermittent problem with a Baxi Bermuda Inset 2 50/4E back boiler. The igniter starts and the pilot light comes on but the boiler doesn't always light, the lockout light coming on after about 30 sec. During this 30 sec period the pilot light is on and the igniter is still sparking . Resetting the boiler by switching odd and back on again resolves the problem - until the next time !! Should I suspect the PCB or something else ? Had this issue with drafts, bending the flame slightly causing the CO flame sensor to trigger the lockout. Not always on windy days either. I wonder if internal drafts is the "issue" with my Inset 3 50/6E? It has never gone into lockout, but when it ignites it takes, inconsistently, from just one spark to very many sparks to ignite the boiler. At times I hear it going click... click... click... and wonder if it is about to go into lockout but it never has. Yet. John -- John Phillips |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Baxi Bermuda Inset 2 Boiler 50/4E lockout | UK diy | |||
Non-modulating condensing boilers? | UK diy | |||
Baxi Bermuda boiler | UK diy | |||
Sensor pipe on Baxi Bermuda inset 2 | UK diy | |||
Baxi back boiler power settings | UK diy |