Baxi Bermuda Inset 2 Boiler 50/4E lockout
Hi,
I have the above boiler and am experiencing the following :- When the timer calls for water the boiler will not ignite. I can hear the ignitor clicking but there is no ignition and the 'lockout' light comes on. If I reset the boiler as per instructions it works OK - igniting multiple times as required until the next new timed period, when the above sequence has to be performed. I have check the pump and motorised valves and they are OK so I suspect the boiler. I rang Baxi who have quoted £219 for a repair. I stated that the boiler was 3.5 years old and already on its second PCB so I was reluctant to spend another £219 on it just yet. Does anyone have any experience with this problem ? Any advice gratefully recieved Brian |
#2
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
On Wed, 02 Nov 2005 11:23:11 -0800, Brian wrote:
Hi, I have the above boiler and am experiencing the following :- When the timer calls for water the boiler will not ignite. I can hear the ignitor clicking but there is no ignition and the 'lockout' light comes on. If I reset the boiler as per instructions it works OK - igniting multiple times as required until the next new timed period, when the above sequence has to be performed. I have check the pump and motorised valves and they are OK so I suspect the boiler. I rang Baxi who have quoted £219 for a repair. I stated that the boiler was 3.5 years old and already on its second PCB so I was reluctant to spend another £219 on it just yet. Does anyone have any experience with this problem ? Any advice gratefully recieved No particular order: No gas - PCB, gas valve, gas supply (yeah right) or blocked injector. No flames - spark electrode shorting (but still ticking), igniter pylon broken, electrode missing or misplaced, debris near ignition area No detection of flames - lead, pylon and electrode (maybe same as above). or PCB. As you can see the PCB mightn't be the cause. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
#3
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
Thanks for the reply Ed,
What I can't understand is that if it's not the PCB, why does resetting the boiler make it work ? I am going to take the firefront off this weekend and see if I can detect any of the problems that you've mentioned. Brian |
#4
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
On Wed, 02 Nov 2005 12:01:59 -0800, Brian wrote:
Thanks for the reply Ed, What I can't understand is that if it's not the PCB, why does resetting the boiler make it work ? I am going to take the firefront off this weekend and see if I can detect any of the problems that you've mentioned. It's an intermittent fault give it another go and you get lucky. This means that it's not likely to be something hard like a broken wire or a bad gas valve. -- Ed Sirett - Property maintainer and registered gas fitter. The FAQ for uk.diy is at http://www.diyfaq.org.uk Gas fitting FAQ http://www.makewrite.demon.co.uk/GasFitting.html Sealed CH FAQ http://www.makewrite.demon.co.uk/SealedCH.html |
#5
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
Thanks again Ed,
I'll give it a good clean and disconnect / reconnect all the electrical connections. Brian |
#6
|
|||
|
|||
Quote:
Id recommend that you test the polarity to your BBU. If ok, ensure that your getting 240v to the appliance..If your getting a spark at the pilot and no flame, check if there is gas to pilot, at time of ignition..you have an oxy pilot and if there is fluff-lint, around the pilots air port then it will not light. try these checks ...post me the results ...good luck....ps you have to be gas qualified to work on any gas appliance |
#7
|
|||
|
|||
Quote:
Id recommend that you test the polarity to your BBU. If ok, ensure that your getting 240v to the appliance..If your getting a spark at the pilot and no flame, check if there is gas to pilot, at time of ignition..you have an oxy pilot and if there is fluff-lint, around the pilots air port then it will not light. try these checks ...post me the results ...good luck....ps you have to be gas qualified to work on any gas appliance |
#8
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
In message , gastec
writes Id recommend that you test the polarity to your BBU. If ok, ensure that your getting 240v to the appliance..If your getting a spark at the pilot and no flame, check if there is gas to pilot, at time of ignition..you have an oxy pilot and if there is fluff-lint, around the pilots air port then it will not light. try these checks ...post me the results ...good luck.... ps you have to be gas qualified to work on any gas appliance What did I say ? I could see it coming No you don't I repeat, if you don't know what you're talking about STFU Stupid **** -- geoff |
#9
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
In message , gastec
writes gastec Wrote: Id recommend that you test the polarity to your BBU. If ok, ensure that your getting 240v to the appliance..If your getting a spark at the pilot and no flame, check if there is gas to pilot, at time of ignition..you have an oxy pilot and if there is fluff-lint, around the pilots air port then it will not light. try these checks ...post me the results ...good luck....ps you have to be gas qualified to work on any gas appliance Id recommend that you test the polarity to your BBU. If ok, ensure that your getting 240v to the appliance..If your getting a spark at the pilot and no flame, check if there is gas to pilot, at time of ignition..you have an oxy pilot and if there is fluff-lint, around the pilots air port then it will not light. try these checks ...post me the results ...good luck....ps you have to be gas qualified to work on any gas appliance He's talking to himself now ha ha -- geoff |
#10
Posted to uk.d-i-y
|
|||
|
|||
Baxi Bermuda Inset 2 Boiler 50/4E lockout
replying to gastec, Muarrif wrote:
Hi I have the exact same problem but we are in 2018 and biker is old. I do not see a resolution confirmation to the above. Could thermostat sensor 232215 be the culprit? -- for full context, visit https://www.homeownershub.com/uk-diy...ut-207350-.htm |