How close can electrical sockets be to sinks ?
there is no regulation about sockets in close proximity to sinks however it
must be suitable for that position. i.e if it is likely to get wet or damp then it must be of the correct ip rateing. therefore normal sockets should not be positioned close to sinks where they could get wet. rule of thumb for ordinary sockets not less than 300mm horizontaly from the sink. loz "No-one" wrote in message ... Any there any regulations about how close electrical sockets can be to sinks (or how far away they must be) ? Regards. |
#2
|
|||
|
|||
How close can electrical sockets be to sinks ?
On Sat, 23 Aug 2003 15:07:23 +0100, "LOZ34"
wrote: rule of thumb for ordinary sockets not less than 300mm horizontaly from the sink. Many thanks. Best regards, |
#3
|
|||
|
|||
How close can electrical sockets be to sinks ?
"No-one" wrote in message ... Any there any regulations about how close electrical sockets can be to sinks (or how far away they must be) ? Regards. Within the bowl itself is generally frowned upon :-) |
#4
|
|||
|
|||
How close can electrical sockets be to sinks ?
On Sat, 23 Aug 2003 21:32:32 +0100, "David W.E. Roberts"
wrote: Within the bowl itself is generally frowned upon :-) Oh I dunno, the result could be quite stimulating :-)) |
#5
|
|||
|
|||
How close can electrical sockets be to sinks ?
There are, you may be suprised to hear, no specific regulations with regard
to placing electrical outlets over or near sinks!!! However, there are regulations which state that a particular electrical item must be suitable for the environment in which it is used. It is this regulation which effectively prevents the use standard electrical fittings near sinks etc, requiring that the outlet must be IP44 in such an area. Her-indoors would not allow such an industrial outlet near the kitchen sink!! The practical, rule-of-thumb answer to the question is "not within 30cm of the edge of the sink, including any intregal draining board" (IEE. Snags & Solutions Handbook) "No-one" wrote in message ... Any there any regulations about how close electrical sockets can be to sinks (or how far away they must be) ? Regards. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Kitchen sockets wiring horizontal | UK diy | |||
Forthcoming Building Regulations on electrical work (Part P) | UK diy | |||
Routeing Electrical FTE cable | UK diy | |||
Moving Electric Sockets from skirting to wall | UK diy |