Hi

It occurs to me that I might need to get someone official to look down
a hole I have dug. The trench is about 1m deep , 8m long and goes down
the side of my house through a part of the house which will be
demolished. That is, it's inside at the moment, but will be outside
eventually. I had planned to lay a mde water supply pipe in 60mm blue
rigid conduit throughout the entire length of this trench. The conduit
rises ~750mm from what will be an outside wall, so I plan to insulate
the pipe in there. I then planned to back fill the trench with
sand/pea shingle and the stuff I dug out to a depth of about 500mm and
similarly lay a 32mm black conduit with draw string to take my new
electricity supply. Then I plan to back fill to a depth of about 200mm
and lay electrical warning tape. The electricity supply will come into
the house pretty close to the water (in a utility room).

I'm doing this because I've been told to prepare for my new electricity
supply by Central Networks. I figured I might as well use the trench
for my water supply, and it's extremely difficult to dig two trenches
through doorways. Upon exiting the building, the trench will have to
split as the electricity must go in a straight line, and the water has
to wander off to the meter. I would like to leave both conduits ready
for supply connection as and when they happen. I would also dearly like
to backfill so I can get to my fridge.

Do I need to get any of this inspected? If I do, and the water
inspector comes after the electricity is connected, I'm going to be in
a right muddle!

LGF

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
trench foundation width [email protected] UK diy 2 October 17th 05 12:15 PM
getting old stove inspected Liam2198 Home Repair 7 December 18th 04 09:03 PM
trenching and other uses of a high pressure washer Jer Home Repair 5 November 18th 04 08:59 PM
Digging trench for MDPE pipe, any tips? Pete C UK diy 4 August 23rd 04 09:37 PM
Digging a trench Vs boring a tunnel Nick Brooks UK diy 21 June 10th 04 07:18 PM


All times are GMT +1. The time now is 10:39 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"