Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?

Karl

  #2   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 440
Default Got no water


"Karl Townsend" wrote in message
...
Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?



First thing I usually do is is look for a blown start capacitor in the
controller box, most of these have a fusable link in them these days and so
when they go out it's pretty obvious....

If you do find a bad cap, replace it and go on about finding out if / why
the pump has been short-cycling--usually, you'll find that the tank is
waterlogged for some reason.

Other than that, bad contacts on the pressure switch are fairly common...and
if the switch has a lever on it, then it could simply be that the power went
out overnight and so you'll need to hold the lever down till the system
develops ~30 lbs or so--a pair of vise grips makes a pretty good "handle
extension" for this as the lever is generally too short to provide enough
leverage to comfortably hold in position by hand..

Don't condemn the pump without checking winding continuity ( suggest check
it AT the wellhead--because this eliminates any bad above-ground connections
that would otherwise skew your readings )......you should have continuity
between all three wires and your actual resistance reading is generally
going pretty low--if it's someplace between about 4 and 10 ohms then I would
suspect that the pump windings are probably okay. Also check for shorts to
ground...

Good luck.


  #3   Report Post  
Posted to rec.crafts.metalworking
Jim Jim is offline
external usenet poster
 
Posts: 2,176
Default Got no water



Karl Townsend wrote:

Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?


Have you looked at the pressure switch?

-jim




Karl

  #4   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 1,417
Default Got no water

On Sat, 29 Oct 2011 13:22:12 -0500
Karl Townsend wrote:

Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?

Karl



I had this link flagged because the pdf had some
troubleshooting info in it (Red Jacket Water Products):

http://completewatersystems.com/wp-c...viceManual.pdf

--
Leon Fisk
Grand Rapids MI/Zone 5b
Remove no.spam for email

  #5   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 10,530
Default Got no water

Sorry to hear that. Saturday, too. Check the usual
electrical, make sure the well pump is getting power. Best
wishes, good luck.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Karl Townsend" wrote in
message ...
Just got in for lunch. My better half is all out of sorts
because we
have no water. A quick look showed its more than circuit
breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody
on RCM
pointed out. Can't find it right now. Any suggestions?

Karl




  #6   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 3,286
Default Got no water

On Sat, 29 Oct 2011 15:20:16 -0400, Leon Fisk
wrote:

On Sat, 29 Oct 2011 13:22:12 -0500
Karl Townsend wrote:

Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?

Karl



I had this link flagged because the pdf had some
troubleshooting info in it (Red Jacket Water Products):

http://completewatersystems.com/wp-c...viceManual.pdf



Thanks, this will do it. I checked all the common stuff, no joy.

So I went to town and made up a coupling adaptor to hook the
irrigation pump to a house hydrant. I can run the irrigation and have
house water. This will get us till Monday or so. Run it one hour twice
a day. No way I don't have a broken part. I'll ohm out the pump next
to determine if its control box or pump.

Karl
  #7   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 3,286
Default Got no water

On Sat, 29 Oct 2011 16:49:16 -0500, Karl Townsend
wrote:

On Sat, 29 Oct 2011 15:20:16 -0400, Leon Fisk
wrote:

On Sat, 29 Oct 2011 13:22:12 -0500
Karl Townsend wrote:

Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?

Karl



I had this link flagged because the pdf had some
troubleshooting info in it (Red Jacket Water Products):

http://completewatersystems.com/wp-c...viceManual.pdf



Thanks, this will do it. I checked all the common stuff, no joy.

So I went to town and made up a coupling adaptor to hook the
irrigation pump to a house hydrant. I can run the irrigation and have
house water. This will get us till Monday or so. Run it one hour twice
a day. No way I don't have a broken part. I'll ohm out the pump next
to determine if its control box or pump.

Karl


http://www.franklin-electric.com/med...IM_Catalog.pdf

for the record, here's the manual I was looking for. About the same as
Leon's link.
  #8   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 7
Default Got no water

On 10/29/2011 12:15 PM, jim wrote:


Karl Townsend wrote:

Just got in for lunch. My better half is all out of sorts because we
have no water. A quick look showed its more than circuit breaker,
motor overload, etc.

I remember a trouble shooting guide on the web that somebody on RCM
pointed out. Can't find it right now. Any suggestions?


Have you looked at the pressure switch?

-jim

I had trouble with bugs in the contacts on the pressure switch,

Bill K7NOM
  #9   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 397
Default Got no water

On Sat, 29 Oct 2011 16:49:16 -0500, Karl Townsend
wrote:

Thanks, this will do it. I checked all the common stuff, no joy.

So I went to town and made up a coupling adaptor to hook the
irrigation pump to a house hydrant. I can run the irrigation and have
house water. This will get us till Monday or so. Run it one hour twice
a day. No way I don't have a broken part. I'll ohm out the pump next
to determine if its control box or pump.

Karl


For the next time this happens, do you have a place in the orchard or
a nearby ridge about 100' (or a bit more) higher than the house?

You put a gravity water tank up there, and you'll have ~45 PSI at the
house - and running any of the well pumps can fill it (reverse action
float switch to start the pump) and give you a healthy reserve - No
more waterlogged captive-air tanks when it's all running on gravity...

Or call it your Fire Tank, run a 6" main down the hill and put
hydrants near the house and the various barns and outbuildings, and
write it off.

Next time - a Pump Pallet in a pickup, or an old Pumper.

-- Bruce --
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
water leak in trackway - utility water or spring water? how to tell? Jim K[_3_] UK diy 7 January 13th 11 02:15 PM
I know how to fix a Water Knock in the Cold Water, is it the same for the Hot Water? Werz Kit Home Repair 6 December 16th 07 05:40 AM
Spray rain water or collected condensate water on compressor to raise efficiency? BoyntonStu UK diy 9 September 30th 07 12:28 PM
Choosing a HOT WATER RECIRCULATOR for QUICK HOT WATER DELIVERY or for HOT WATER ON D'MAND is now a whole lot easier. [email protected] Home Repair 22 June 7th 06 01:09 AM
hot water recirculator, instant hot water but not a water heating unit, saves water, gas, time, money HeatMan Home Repair 0 August 24th 03 12:26 PM


All times are GMT +1. The time now is 04:07 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"