  #1   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 3,286
Default large air line

I'm over to "the Kid's" place tommorrow. We're moving the air
compressor to his basement and setting up scaffold for sandblasting
the whole exterior of the house. He just found 100' of 3/8 line
restricts the blaster too much.

His question, what should be used for temporary large ID air line?

Karl

  #2   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 4,632
Default large air line

Karl Townsend fired this volley in
:

His question, what should be used for temporary large ID air line?

Karl


Karl, when we were blasting the paint off'n Swift boats in RVN, we used
1" line for anything up to the blaster rig itself. Then, whatever sized
lines it had.

It's not "safe" for shop piping, but sch-40 pvc is rated higher than
you'll be using it.

I've done that a few times to get air 200-300 feet away for a job like
blasting my gate posts clean.

LLoyd
  #3   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 6,746
Default large air line


Karl Townsend wrote:

I'm over to "the Kid's" place tommorrow. We're moving the air
compressor to his basement and setting up scaffold for sandblasting
the whole exterior of the house. He just found 100' of 3/8 line
restricts the blaster too much.

His question, what should be used for temporary large ID air line?

Karl


You can probably rent larger air line from United, Nations or other
equipment rental places that rent trailer type compressors at a
reasonable rate. You might find renting larger blast equipment is
practical as well if it saves a lot of time and labor. Otherwise a roll
of 1/2" or 3/4" PEX tubing and a couple fittings should work, and be
useful for redeployment later as water plumbing.
  #4   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 2,473
Default large air line

3/4" garden hose?
  #5   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 533
Default large air line

In article ,
"Lloyd E. Sponenburgh" lloydspinsidemindspring.com wrote:

Karl Townsend fired this volley in
:

His question, what should be used for temporary large ID air line?

Karl


Karl, when we were blasting the paint off'n Swift boats in RVN, we used
1" line for anything up to the blaster rig itself. Then, whatever sized
lines it had.

It's not "safe" for shop piping, but sch-40 pvc is rated higher than
you'll be using it.


It's not rated for air *at all*. No need for "scare" quotes - it's not
safe for use with air, unless it's completely contained in ground or a
shatter shield. Fundamentally different things happen when a plastic
pipe containing 100PSI water and one containing 100PSI air crack. One
results in shrapnel.

http://www.charlottepipe.com/Default...Page=PVC40Pipe

Large diameter rubber air compressor hose (as seen on a jackhammer hear
you) - as already mentioned, it can be rented from the same places that
rent towed compressors and jackhammers. Or you might find a roll at an
auction.

--
Cats, coffee, chocolate...vices to live by
Please don't feed the trolls. Killfile and ignore them so they will go away.


  #6   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 10,530
Default large air line

Use a couple T, and run parallel dual lines.

Garden hose might work, if it's heavy duty stuff.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Karl Townsend" wrote in
message ...
I'm over to "the Kid's" place tommorrow. We're moving the
air
compressor to his basement and setting up scaffold for
sandblasting
the whole exterior of the house. He just found 100' of 3/8
line
restricts the blaster too much.

His question, what should be used for temporary large ID
air line?

Karl


  #7   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 3,444
Default large air line

Bob Engelhardt wrote:
3/4" garden hose?


It works great!

(Don't tell anybody I told you that though.)



--Winston
  #8   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 4,632
Default large air line

Ecnerwal fired this volley
in :

It's not rated for air *at all*. No need for "scare" quotes - it's not
safe for use with air, unless it's completely contained in ground or a
shatter shield. Fundamentally different things happen when a plastic
pipe containing 100PSI water and one containing 100PSI air crack. One
results in shrapnel.


Yes, Nanny. I won't do that anymore.

LLoyd
  #9   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 47
Default large air line

A rough calc for 100' of line and 20 cfm gives a pressure drop of 48 psi for
..5" id, 5.6 psi for .75" id, and 1.2 psi for 1" id - diameter is your FRIEND
:-).

-----
Regards,
Carl Ijames
"Karl Townsend" wrote in message
...

I'm over to "the Kid's" place tommorrow. We're moving the air
compressor to his basement and setting up scaffold for sandblasting
the whole exterior of the house. He just found 100' of 3/8 line
restricts the blaster too much.

His question, what should be used for temporary large ID air line?

Karl


  #10   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 235
Default large air line

On Wed, 08 Jun 2011 17:26:05 -0400, Bob Engelhardt
wrote:

3/4" garden hose?


The commercial ones are bigger. Reminds me of doing a Casino pool and
had to hear about three sand blasters in their huge "courtyard" for a
week or more. I can still imagine the shriek.

I have a blue one with stainless connectors...


SW


  #11   Report Post  
Posted to rec.crafts.metalworking
external usenet poster
 
Posts: 10,530
Default large air line

Sounds workable. I'd want to use good quality hose.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
..


"Winston" wrote in message
...
Bob Engelhardt wrote:
3/4" garden hose?


It works great!

(Don't tell anybody I told you that though.)



--Winston


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
"Grass Gator n'Cut Fixed 4 Line Head" Weed Wacker Replacement For Bump-Line Feed Head ? Robert11 Home Repair 3 July 4th 05 02:49 PM
how large EMF field when Degaussing large CRT? Mike Sampieri Electronics 2 June 20th 05 09:20 PM
how large EMF field when Degaussing large CRT? Mike Sampieri Electronics Repair 1 June 20th 05 08:48 PM
FS - Large endmills for sale ( at least too large for my use) [email protected] Metalworking 2 February 7th 05 12:45 PM
for Sale Large SPINDLE Adaptor and Large 3C Collet for S/Bend LATHE [email protected] Metalworking 0 January 11th 05 09:32 PM


All times are GMT +1. The time now is 07:35 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"