Hi,

We are developing our basement and are receiving different
recommendations from different contractors. We have 8.5 foot ceiling
and want the basement to be warm. Some contractors state that it is
best to install the forced air heat runs close to the ceiling (near
windows) and cold air returns near the floor. Other contractors state
that the forced
air heats runs should be near the floor and the cold air returns
should be near the floor (across the room).

Before we invest all this money, does anyone know which recommendation
is correct? We live in Canada and do have cold winters. The main
"rec room" that will be developed in the basement will probably have a
gas fireplace. The total square footage of our basement is 850.

Any help or recommendations would be appreciated.

John
  #2   Report Post  
HVAC fella
 
Posts: n/a
Default

'Other contractors state that the forced
air heats runs should be near the floor and the cold air returns should
be near the floor (across the room).'

ME: This is the best. The supplys should be near the floor and close
to windows if at all possible. Returns should be as far away from the
supplys to eliminate stratification , and near the floor also. If you
live in a very frigid part of North America, then supplementing with
baseboard electric may be required also..especially on the coldest of
days.

  #3   Report Post  
Tony Hwang
 
Posts: n/a
Default

Joh Harris wrote:
Hi,

We are developing our basement and are receiving different
recommendations from different contractors. We have 8.5 foot ceiling
and want the basement to be warm. Some contractors state that it is
best to install the forced air heat runs close to the ceiling (near
windows) and cold air returns near the floor. Other contractors state
that the forced
air heats runs should be near the floor and the cold air returns
should be near the floor (across the room).

Before we invest all this money, does anyone know which recommendation
is correct? We live in Canada and do have cold winters. The main
"rec room" that will be developed in the basement will probably have a
gas fireplace. The total square footage of our basement is 850.

Any help or recommendations would be appreciated.

John

Hi,
My basement has hot air vent at floor level and return duct like you
mentioned. I think it's only logical. I live in Calgary. Basement is
~1300 sq. ft. of 2 storey house and ceiling is 8 ft. high.
Basement walls are insulated with R12 fiberglass batts with vapor
barrier top to bottom and it was finished when house was built.
It's cool in summer, warm in winter.
Tony
  #4   Report Post  
Mikepier
 
Posts: n/a
Default

Interesting. I just moved into my house a few months ago and I have a
hot air system with an A/C coil added to it for central air. My
basement has the vents at ceiling level by the windows. My return grill
is at the furnace. For some reason someone marked on the return grill
"open for cooling, close for heat". Right now, the grill is closed. I
also have return grills up athe the 1st and 2nd floors and those grills
are open. Should I have my return grill in the basement open? Now that
I read this discussion it makes sense to have the return grill open to
draw the heat down from the vents.

  #5   Report Post  
 
Posts: n/a
Default

HVAC fella wrote:

...The supplys should be near the floor and close to windows if at all
possible. Returns should be as far away from the supplys to eliminate
stratification , and near the floor also.


Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior walls.

Nick



  #6   Report Post  
Dr Halonfire$
 
Posts: n/a
Default

wrote:
HVAC fella wrote:

...The supplys should be near the floor and close to windows if at
all possible. Returns should be as far away from the supplys to
eliminate stratification , and near the floor also.


Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior
walls.

Nick


Dave (HVACFella.) should know this; he's full of hot air and blows
regularly. What happened to DaveinLakeVilla, DaveinIllinois, and all your
other nicks? Why have you gone back to HVACFella? You were exposed as a hack
many time under that one last year! The inconsistency of this retard never
ceases to amaze me!

Incidentally why are you no longer preaching your version of Xianity all
over usenet? Have you finally realised that all that we Pagans said in the
dating groups you trolled was true? Or did you just get fedup with banging
your head on a brick wall? Don't assume that I disagree with you having your
own individual non-Pagan belief in any way; that is your choice and your
right. : While I may not agree with your dogma I do agree that you have
every right to believe it on a personal level. It seems strange that you
have suddenly abruptly stopped trying to shove it down people's throats
against their will. Why the change of tac?

--
My part-time website is at
http://5110.sytes.net
The full-time one is at http://www.geocities.com/spmf38 , but there's
no TechSection there.

  #7   Report Post  
~KJPRO~
 
Posts: n/a
Default

wrote in message
...
HVAC fella wrote:

...The supplys should be near the floor and close to windows if at all
possible. Returns should be as far away from the supplys to eliminate
stratification , and near the floor also.


Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior walls.

Nick



Returns on outside...floor level......TO FUNNY!!

~kjpro~



  #8   Report Post  
 
Posts: n/a
Default

~KJPRO~ KJPRO @ STARBAND.NET wrote:

...The supplys should be near the floor and close to windows if at all
possible. Returns should be as far away from the supplys to eliminate
stratification , and near the floor also.


Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior walls.


Returns on outside...floor level......TO FUNNY!!


This speaks to typical HVAC criminal ignorance.

Nick

  #9   Report Post  
~KJPRO~
 
Posts: n/a
Default

wrote in message
...
~KJPRO~ KJPRO @ STARBAND.NET wrote:

...The supplys should be near the floor and close to windows if at

all
possible. Returns should be as far away from the supplys to eliminate
stratification , and near the floor also.

Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior walls.


Returns on outside...floor level......TO FUNNY!!


This speaks to typical HVAC criminal ignorance.

Nick


Just what profession are you associated with?

Give you a clue, mine is HVAC!

~kjpro~



  #10   Report Post  
Steve@carolinabreezehvac
 
Posts: n/a
Default


wrote in message
...
~KJPRO~ KJPRO @ STARBAND.NET wrote:

...The supplys should be near the floor and close to windows if at

all
possible. Returns should be as far away from the supplys to eliminate
stratification , and near the floor also.

Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior walls.


Returns on outside...floor level......TO FUNNY!!


This speaks to typical HVAC criminal ignorance.

Nick


Actually, Daves post did....KJs didnt.

I guess you dont know a thing about Manual D, or how to insure that a home
is PROPERLY cooled and heated..

I guess all this time we have been doing it so wrong...

Please, Mr WannaBe Master HVAC Tech....tell those of us who know better what
you know...or think you know.



  #11   Report Post  
zyp
 
Posts: n/a
Default

Mike;

I'd guess that the previous home owner opened the bottom return grille
during cooling because he / she didn't have sufficent return upstairs in the
first place.

A common problem with many HVAC installations is there is insufficent
return.. Call your local proffesional out, have him / her check your ducts
and the layout. You'll problable find that the ducts weren't designed to
any particlar mean, and, you could drastically cut your utility bill by
having them professionally designed and installed.

It is a known fact by the trade that many systems have too small of returns
and the duct system usually leaks somthing on the order of 20% - 30%. So
give your neighborhood pro a call and have him / her take a look.

Zyp

"Mikepier" wrote in message
ups.com...
Interesting. I just moved into my house a few months ago and I have a
hot air system with an A/C coil added to it for central air. My
basement has the vents at ceiling level by the windows. My return grill
is at the furnace. For some reason someone marked on the return grill
"open for cooling, close for heat". Right now, the grill is closed. I
also have return grills up athe the 1st and 2nd floors and those grills
are open. Should I have my return grill in the basement open? Now that
I read this discussion it makes sense to have the return grill open to
draw the heat down from the vents.



  #12   Report Post  
 
Posts: n/a
Default

Steve@carolinabreezehvac wrote:

Warm air rises. You can save heat and blower power by putting returns
in the floor near windows and supplies near the top of interior walls.


I guess all this time we have been doing it so wrong...


Not necessarily. Harry Thomason had the right idea.

tell those of us who know better what you know...or think you know.


There's a typical HVAC criminal mixture of ignorance and arrogance :-)

We can save heat power because cooler windows lose less heat to the outdoors.
We can save blower power because an interior wall or an enclosed stairwell can
act as a convector, with a column of warm air that creates a bouyant force
above a heat source. Got something against saving fuel and electricity?

Why fight nature? House air tends to cool and fall near exterior walls.

Nick

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Return ducts in basement reducing heating efficiency?! jeff Home Repair 5 November 9th 04 09:38 PM
Location for new sump pit, etc Puddin' Man Home Repair 6 December 7th 03 07:44 PM
Advice needed on new basement - sump hole higher than rest of basement Doug Swetland Home Ownership 1 September 24th 03 06:09 PM
Advice needed on new basement - sump hole higher than rest of basement Brad Home Ownership 1 September 24th 03 05:51 PM
Floor choice for walkout basement? FC Home Ownership 0 July 1st 03 03:28 PM


All times are GMT +1. The time now is 09:31 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"