Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default Pilot light but won't stay lit

I have a Majestic, direct vent, gas log fireplace model DV360 that is 16 years old. When I try to light it, the pilot usually lights quickly and will stay lit as long as I am pushing in on the pilot knob. I have tried holding the button anywhere between 1 to 5 minutes. I also took a lighter to the TH and TP to try and make them hotter. The problem is, the second I release the pushed-in pilot knob, so that I can turn it to ON, the flame goes out. I have tried cleaning the thermocouple and thermopile and blowing out the pilot the best I can. I can't see the burner tube because I believe it is hidden under a burner plate/burner housing assembly, so I can't clean that. The pilot is a nice blue and shoots out in three directions. It just that the pilot won't stay lit long enough so that I can turn the knob to ON. I also have a wall switch that I normally don't turn on until after the pilot stays lit on its own but I tried turning it on while trying to light the pilot but it did help any. The TH, TP and Pilot look to be clean and not at all corroded. Funny thing is, it was working fine for the last month and then stopped lighting. Any suggestions on what to try next.

--
For full context, visit https://www.homeownershub.com/mainte...t-3083934-.htm

  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 256
Default Pilot light but won't stay lit

On 12/28/20 11:15 AM, Emptynester wrote:
I have a Majestic, direct vent, gas log fireplace model DV360 that is 16
years old. When I try to light it, the pilot usually lights quickly and
will stay lit as long as I am pushing in on the pilot knob.Â* I have
tried holding the button anywhere between 1 to 5 minutes.Â* I also took a
lighter to the TH and TP to try and make them hotter.Â* The problem is,
the second I release the pushed-in pilot knob, so that I can turn it to
ON, the flame goes out. I have tried cleaning the thermocouple and
thermopile and blowing out the pilot the best I can. I can't see the
burner tube because I believe it is hidden under a burner plate/burner
housing assembly, so I can't clean that.Â* The pilot is a nice blue and
shoots out in three directions.Â* It just that the pilot won't stay lit
long enough so that I can turn the knob to ON.Â* I also have a wall
switch that I normally don't turn on until after the pilot stays lit on
its own but I tried turning it on while trying to light the pilot but it
did help any.Â* The TH, TP and Pilot look to be clean and not at all
corroded. Funny thing is, it was working fine for the last month and
then stopped lighting.Â* Any suggestions on what to try next.


Classic symptoms of a failed thermocouple. It needs replaced. Nice that
it lasted 16 years.
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 15,279
Default Pilot light but won't stay lit

On Monday, December 28, 2020 at 11:19:29 AM UTC-5, wrote:
On 12/28/20 11:15 AM, Emptynester wrote:
I have a Majestic, direct vent, gas log fireplace model DV360 that is 16
years old. When I try to light it, the pilot usually lights quickly and
will stay lit as long as I am pushing in on the pilot knob. I have
tried holding the button anywhere between 1 to 5 minutes. I also took a
lighter to the TH and TP to try and make them hotter. The problem is,
the second I release the pushed-in pilot knob, so that I can turn it to
ON, the flame goes out. I have tried cleaning the thermocouple and
thermopile and blowing out the pilot the best I can. I can't see the
burner tube because I believe it is hidden under a burner plate/burner
housing assembly, so I can't clean that. The pilot is a nice blue and
shoots out in three directions. It just that the pilot won't stay lit
long enough so that I can turn the knob to ON. I also have a wall
switch that I normally don't turn on until after the pilot stays lit on
its own but I tried turning it on while trying to light the pilot but it
did help any. The TH, TP and Pilot look to be clean and not at all
corroded. Funny thing is, it was working fine for the last month and
then stopped lighting. Any suggestions on what to try next.

Classic symptoms of a failed thermocouple. It needs replaced. Nice that
it lasted 16 years.


+1

What are a TH and TP? TP is probably thermopile, but then he says he has
that and a thermocouple, which makes no sense to me. If the thermocouple
is bad, you can heat it until the cows come home and it won't stay lit. With
a meter he could check it. It could also be the wiring or the gas valve, but
the TC is the prime suspect.






  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,564
Default Pilot light but won't stay lit

On Mon, 28 Dec 2020 16:15:02 +0000, Emptynester
wrote:

I have a Majestic, direct vent, gas log fireplace model DV360 that is 16 years old. When I try to light it, the pilot usually lights quickly and will stay lit as long as I am pushing in on the pilot knob. I have tried holding the button anywhere between 1 to 5 minutes. I also took a lighter to the TH and TP to try and make them hotter. The problem is, the second I release the pushed-in pilot knob, so that I can turn it to ON, the flame goes out. I have tried cleaning the thermocouple and thermopile and blowing out the pilot the best I can. I can't see the burner tube because I believe it is hidden under a burner plate/burner housing assembly, so I can't clean that. The pilot is a nice blue and shoots out in three directions. It just that the pilot won't stay lit long enough so that I can turn the knob to ON. I also have a wall switch that I normally don't turn on until after the pilot stays lit on its own but I tried turning it on while trying to light the pilot but it did

help
any. The TH, TP and Pilot look to be clean and not at all corroded. Funny thing is, it was working fine for the last month and then stopped lighting. Any suggestions on what to try next.

Better than 90% you have a failed thermocouple or thermopule,
depending on your unit. If it's not the thermocouple it COULD be the
gas valve - very unlikely though.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
gas fireplace won't start-up - pilot is lit [email protected] Home Repair 84 March 29th 21 08:28 PM
Pilot light in gas, wall heater doesn't stay lit. David Farber Home Repair 18 December 31st 14 11:09 PM
ways to screw up replacing a thermocouple? (pilot won't stay lit) Jim Home Repair 3 September 22nd 06 12:10 AM
Propane Stove: Pilot Light Won't Stay Light Testing Thermopile John F. Home Repair 5 April 25th 06 06:34 PM
Water heater pilot light won't stay lit - thermocouple replaced Tai Home Repair 1 November 30th 04 04:42 PM


All times are GMT +1. The time now is 08:37 PM.