Steel boiler problem
Greetings,
I have a 20 year old Burnham steel boiler (model RS110). I recently found that the inspection port/hole has a gret deal of soot around it. Mostly on the top. Upon futher inspection, it appears that the firebox material inside the combustion chamber has "slid" downward, partially obsscuring the port. I am relatively familiar with the burner aspect of the furnace, the primary and secondary controls, cleaning & maintaining them as well as cleaning the boiler flue tubes annually. I have not ever been into or done anything with the combustion chamber or boiler itself other than take the sides off for access to clean it or take the bruner assembly out for cleaning, replacing the nozzl;e and adjusting the electrodes. I checked the Burnham web site, and they do have a replacement combustion chamber available. I don't even know if I need one, but I suspect I do. Is it worth (with the boiler at this ripe age of 20 years) to replace the chamber, or would I be better off investing in a new boiler? Is this something that I can do my self or are special tools/procedures necessary? I have installed a new boilers before (2 times) so I am familiar with the units in general. What is entailed in replacing the chamber? Big job? little job? Time? Should I save myself the time and aggravation and just have someone else replace the chamber? Any help or advice is much appreciated. Thanks. Paul.../NH |
#2
|
|||
|
|||
Steel boiler problem
"PW" wrote in message news:YoXBc.70521$2i5.57314@attbi_s52... Greetings, I have a 20 year old Burnham steel boiler (model RS110). I recently found that the inspection port/hole has a gret deal of soot around it. Mostly on the top. Upon futher inspection, it appears that the firebox material inside the combustion chamber has "slid" downward, partially obsscuring the port. I am relatively familiar with the burner aspect of the furnace, the primary and secondary controls, cleaning & maintaining them as well as cleaning the boiler flue tubes annually. I have not ever been into or done anything with the combustion chamber or boiler itself other than take the sides off for access to clean it or take the bruner assembly out for cleaning, replacing the nozzl;e and adjusting the electrodes. I checked the Burnham web site, and they do have a replacement combustion chamber available. I don't even know if I need one, but I suspect I do. Is it worth (with the boiler at this ripe age of 20 years) to replace the chamber, or would I be better off investing in a new boiler? Is this something that I can do my self or are special tools/procedures necessary? I have installed a new boilers before (2 times) so I am familiar with the units in general. What is entailed in replacing the chamber? Big job? little job? Time? Should I save myself the time and aggravation and just have someone else replace the chamber? Any help or advice is much appreciated. Thanks. Paul.../NH I think replacement would be doable and have done so with a 20 yer old Weil-McClain boiler. Admittedly, that's a cast iron unit. Despite claims to the contrary, I've seen steel boilers last 40 years. Their life depends on many things, such as how oxygen free the water has been. The more the boiler water has been changed out, the more oxygen there has been to aid corrosion of the steel. While the original Burnham combustion chamber might be ideal, many heating supply houses offer a "wet pack" generic replacement. They can be molded to fit and harden rapidly. BTW, if you look into the chamber, how bad is the combustion chamber wall, the "target wall", directly opposite the flame front? That's the area that is most critical. Doug |
#3
|
|||
|
|||
Steel boiler problem
"sparks065" wrote in message hlink.net...
"PW" wrote in message news:YoXBc.70521$2i5.57314@attbi_s52... Greetings, I have a 20 year old Burnham steel boiler (model RS110). I recently found that the inspection port/hole has a gret deal of soot around it. Mostly on the top. Upon futher inspection, it appears that the firebox material inside the combustion chamber has "slid" downward, partially obsscuring the port. I am relatively familiar with the burner aspect of the furnace, the primary and secondary controls, cleaning & maintaining them as well as cleaning the boiler flue tubes annually. I have not ever been into or done anything with the combustion chamber or boiler itself other than take the sides off for access to clean it or take the bruner assembly out for cleaning, replacing the nozzl;e and adjusting the electrodes. I checked the Burnham web site, and they do have a replacement combustion chamber available. I don't even know if I need one, but I suspect I do. Is it worth (with the boiler at this ripe age of 20 years) to replace the chamber, or would I be better off investing in a new boiler? Is this something that I can do my self or are special tools/procedures necessary? I have installed a new boilers before (2 times) so I am familiar with the units in general. What is entailed in replacing the chamber? Big job? little job? Time? Should I save myself the time and aggravation and just have someone else replace the chamber? Any help or advice is much appreciated. Thanks. Paul.../NH I think replacement would be doable and have done so with a 20 yer old Weil-McClain boiler. Admittedly, that's a cast iron unit. Despite claims to the contrary, I've seen steel boilers last 40 years. Their life depends on many things, such as how oxygen free the water has been. The more the boiler water has been changed out, the more oxygen there has been to aid corrosion of the steel. While the original Burnham combustion chamber might be ideal, many heating supply houses offer a "wet pack" generic replacement. They can be molded to fit and harden rapidly. BTW, if you look into the chamber, how bad is the combustion chamber wall, the "target wall", directly opposite the flame front? That's the area that is most critical. Doug Based on my experience with steel boilers, I'd replace it. I have two steel boilers in my apartment building, each slightly more than 20 years old. Every company I've had come in look at them has said they're "junk" and should be replaced. I know these guys are not unbiased -- t hey want to sell me a boiler -- but based on what I've seen of these boilers (they're rusting badly), I'd say they may be right. Of course a chamber replacement is relatively inexpensive -- I had one done on an older boiler and it only cost me $75. John |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Combi boiler hot water problem | UK diy | |||
Need Help with Gas Boiler Vent Problem! | Home Repair | |||
Another heating problem question! | UK diy | |||
Halstead boiler problem | UK diy |