#1
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
I had a lot of water enter my townhouse during the 1st week of March when there was ice damming going on. Water came in where the siding meets the roof. Today the property management company for my condo association sent a repairman over to perform a repair of my roof. All he did was use a caulking gun to put a bead of sealant (roof Xtender 100) where the siding meets the roof.
Can those of you with roofing experience please tell me if this is really an acceptable repair for this situation? If not, then why not, and what type of repair would be acceptable. As you can probably guess, I do already have my own ideas about this, but I would like to hear your opinions first, as well as your opinions on how I should go about convincing the Association that this isn't an acceptable roof repair Please see these links of the repair that was performed: http://www.screencast.com/t/dQLzmNTk78K http://www.screencast.com/t/FLZ0RNbHr Thanks. J. |
#3
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
Okay, but my concern isn't really how it looks cosmetically...my concern is this really the proper way to repair the roof so that water won't get in?
No matter how it looks, there is only /one/ acceptable repair: The one that does not allow water to get in. |
#4
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
|
#5
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On 3/19/2015 7:49 PM, wrote:
I had a lot of water enter my townhouse during the 1st week of March when there was ice damming going on. Water came in where the siding meets the roof. Today the property management company for my condo association sent a repairman over to perform a repair of my roof. All he did was use a caulking gun to put a bead of sealant (roof Xtender 100) where the siding meets the roof. Can those of you with roofing experience please tell me if this is really an acceptable repair for this situation? If not, then why not, and what type of repair would be acceptable. As you can probably guess, I do already have my own ideas about this, but I would like to hear your opinions first, as well as your opinions on how I should go about convincing the Association that this isn't an acceptable roof repair Please see these links of the repair that was performed: http://www.screencast.com/t/dQLzmNTk78K http://www.screencast.com/t/FLZ0RNbHr Thanks. J. Looks like it will be just fine for a while. Weeks, maybe months. I'd have looked at some sor of flasjing, best installed when the roof was done. |
#6
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
Looks like it will be just fine for a while. Weeks, maybe months. I'd have looked at some sor of flasjing, best installed when the roof was done. It likely has flashing underneath...but obviously since it leaked something went wrong. |
#7
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On Thursday, March 19, 2015 at 9:16:40 PM UTC-4, wrote:
Looks like it will be just fine for a while. Weeks, maybe months. I'd have looked at some sor of flasjing, best installed when the roof was done. It likely has flashing underneath...but obviously since it leaked something went wrong. Bingo. Flashing. That repair is a hack job. If the flashing was properly done, ice daming should not be able to back up water high enough to go over top of it. And that caulk at the roofline isn't where the problem is. The problem is something is wrong with the flashing. If ice daming got water over the flashing, it's going to get it over the 1/2" height of that caulk too. Where vertical surfaces meet the roof, flashing is the answer, never caulk. |
#8
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
I don't know what else you might do. Under normal
conditions a spot like that just drains, and probably has flashing under the roofing, going up under the siding. So the tar (if that's what it is) is just sealant for good measure. |
#9
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On Thursday, March 19, 2015 at 9:22:34 PM UTC-4, trader_4 wrote:
On Thursday, March 19, 2015 at 9:16:40 PM UTC-4, wrote: Looks like it will be just fine for a while. Weeks, maybe months. I'd have looked at some sor of flasjing, best installed when the roof was done. It likely has flashing underneath...but obviously since it leaked something went wrong. Bingo. Flashing. That repair is a hack job. If the flashing was properly done, ice daming should not be able to back up water high enough to go over top of it. And that caulk at the roofline isn't where the problem is. The problem is something is wrong with the flashing. If ice daming got water over the flashing, it's going to get it over the 1/2" height of that caulk too. Where vertical surfaces meet the roof, flashing is the answer, never caulk. Another factor to consider, in climates subject to ice daming, under the shingles, code typically requires that an water barrier underlayment be used from the bottom of the roof up until the point where the roof is 2ft into the heated living space. In other words, if you have a soffit overhang that is 2ft, then a wall of the house, you have water barrier for the first 4ft, then regular underlayment/felt, is OK. The idea is that any freeze/thaw cycles can cause water to back up the roof at that point. By having a water barrier underlayment, it can back up 2ft and still not penetrate inside. |
#10
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
|
#11
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On Friday, March 20, 2015 at 6:57:25 AM UTC-4, dadiOH wrote:
wrote: Okay, but my concern isn't really how it looks cosmetically...my concern is this really the proper way to repair the roof so that water won't get in? Temporarily, maybe, IF the caulk was thoroughly applied. However, caulk isn't forever. Water doesn't run up hill so there should be flashing under the shingles extending maybe a foot down slope; that flashing should also extend up under the siding for about the same distance. There needs to be step flashing all the way down that slope where the vertical meets the roof and also flashing all the way across the top. That is roofing 101. The water that got in either got in because the flashing is missing or incorrectly installed or else the water backed up far enough from ice daming that it got over the shingle lap. And having looked at the pics again, there is something else here that is very wrong. That siding comes right down to the roof. It shouldn't. There should be about a 3/4" gap between where the siding ends and the shingles. The flashing would be visible there. You don't want the siding in contact with the roof, it wicks up water, water gets under it, it stays wet for days and it rots. |
#12
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On 3/19/2015 9:16 PM, wrote:
Looks like it will be just fine for a while. Weeks, maybe months. I'd have looked at some sor of flasjing, best installed when the roof was done. It likely has flashing underneath...but obviously since it leaked something went wrong. Ed's talking about Norwegian Flasjing. Those scandanavians really know how to do roofs. I've seen folks in PRNY put a load of black tar where the roof meets the chimney, for example. - .. Christopher A. Young learn more about Jesus .. www.lds.org .. .. |
#13
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On 3/19/2015 7:49 PM, wrote:
I had a lot of water enter my townhouse during the 1st week of March when there was ice damming going on. Water came in where the siding meets the roof. Today the property management company for my condo association sent a repairman over to perform a repair of my roof. All he did was use a caulking gun to put a bead of sealant (roof Xtender 100) where the siding meets the roof. Can those of you with roofing experience please tell me if this is really an acceptable repair for this situation? If not, then why not, and what type of repair would be acceptable. As you can probably guess, I do already have my own ideas about this, but I would like to hear your opinions first, as well as your opinions on how I should go about convincing the Association that this isn't an acceptable roof repair Please see these links of the repair that was performed: http://www.screencast.com/t/dQLzmNTk78K http://www.screencast.com/t/FLZ0RNbHr Thanks. J. That has the black and shiny look of roofing tar. I've seen some folks apply that with a bucket and trowel. Hope it works for you, for a long time. Acceptable? Unsure. - .. Christopher A. Young learn more about Jesus .. www.lds.org .. .. |
#14
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On Fri, 20 Mar 2015 08:07:18 -0400, Stormin Mormon
wrote: Please see these links of the repair that was performed: http://www.screencast.com/t/dQLzmNTk78K http://www.screencast.com/t/FLZ0RNbHr Thanks. J. That has the black and shiny look of roofing tar. I've seen some folks apply that with a bucket and trowel. Hope it works for you, for a long time. Acceptable? Unsure. OP. Is this an after construction roof add on? Side, end and under photos maybe? Curious minds and all... |
#15
Posted to alt.home.repair
|
|||
|
|||
Is this really an acceptable roof repair?
On Thursday, March 19, 2015 at 9:22:34 PM UTC-4, trader_4 wrote:
On Thursday, March 19, 2015 at 9:16:40 PM UTC-4, wrote: Looks like it will be just fine for a while. Weeks, maybe months. I'd have looked at some sor of flasjing, best installed when the roof was done. It likely has flashing underneath...but obviously since it leaked something went wrong. Bingo. Flashing. That repair is a hack job. If the flashing was properly done, ice daming should not be able to back up water high enough to go over top of it. And that caulk at the roofline isn't where the problem is. The problem is something is wrong with the flashing. If ice daming got water over the flashing, it's going to get it over the 1/2" height of that caulk too. Where vertical surfaces meet the roof, flashing is the answer, never caulk. Here's a diagram of how the step flashing should be done on the raked sided: http://www.civil.uwaterloo.ca/beg/Dr...of_flash-1.gif And a pic of it when done: http://www.nachi.org/images10/1-13-9.jpg Notice the intentional ~1" gap between where the siding ends and the roof. And on the other part, ie the headwall across the top: http://www.nachi.org/images10/1-14-1.jpg The above is the way it's done. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Slate roof - Tile roof.. acceptable method of joining? | UK diy | |||
Roof tile glue to repair recently cracked clay re-roof tiles (doesit exist?) | Home Repair | |||
"Can" Vents Acceptable on Low-Pitched Roof? | Home Repair | |||
"Can" Vents Acceptable on Low-Pitched Roof? | Home Ownership | |||
Repair flat roof or have a sloping tiled roof put on? | UK diy |