Default Sump Pump Problems

Testing the sump pump I discovered that the pump did not function.
The sump pump that we have is less the 6 yrs old, but we discovered
during testing that it was not working.

Testing: poured a 5 gallon bucket of water into the sump.

1.) The pump did nothing.
Took stick and slapped the float switch. After 3 knocks the pump
kicked on.

2.) Then I discovered that the pump was spinning, but failed to pump
any water.
Started to remove pump by loosening the hose clamps, when I herd it
suck some air.
Hearing this, I plugged the pump back in and it kicked on and emptied
the sump down past the float. (not entirely empty)

3.) Poured another bucket of water in and this time it behaved
correctly.

Why did the pump act this way ? Do I need to replace the float switch
or the pump ? why did the air lock keep the pump from functioning ?

Pump: Zoeller M53 - 1/3 HP Cast Iron Submersible
(at least that’s what it looks like, tag is too crusty to read).
The float switch is not what is pictured on the Zoeller site, its a
black cylinder about 2.5 in dia. and 2.5 in high mounted on an arm
next to the pump.

Thanks







  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 156
Default Sump Pump Problems

On Wed, 10 Aug 2011 16:27:38 -0700 (PDT), sid
wrote:

Testing the sump pump I discovered that the pump did not function.
The sump pump that we have is less the 6 yrs old, but we discovered
during testing that it was not working.

Testing: poured a 5 gallon bucket of water into the sump.

1.) The pump did nothing.
Took stick and slapped the float switch. After 3 knocks the pump
kicked on.

2.) Then I discovered that the pump was spinning, but failed to pump
any water.
Started to remove pump by loosening the hose clamps, when I herd it
suck some air.
Hearing this, I plugged the pump back in and it kicked on and emptied
the sump down past the float. (not entirely empty)

3.) Poured another bucket of water in and this time it behaved
correctly.

Why did the pump act this way ? Do I need to replace the float switch
or the pump ? why did the air lock keep the pump from functioning ?

Pump: Zoeller M53 - 1/3 HP Cast Iron Submersible
(at least that’s what it looks like, tag is too crusty to read).
The float switch is not what is pictured on the Zoeller site, its a
black cylinder about 2.5 in dia. and 2.5 in high mounted on an arm
next to the pump.

Thanks


First Air lock. There should be a small (1/8 dia or less) hole
drilled in the outlet pipe a couple of inches up from the pump base.
This will prevent air lock. Water will shoot out the hole when the
pump is running; that's ok.

As for why it didn't kick on, I'm guessing your pump doesn't run very
often and the switch contacts probably got a little corroded. The
switch is designed to wipe the contacts slightly each cycle to keep
them clean, but if it doesn't run often they can fail this way.

Zoeller sells a replacement switch kit for the M53. It's a bit tricky
to install because of the need to seal it well since it's under water
some times. But I'll bet if you dump a bucket of water every month or
so to cycle the pump it will be fine.

Having said that, because the M53 uses a mechanical switch, they do
wear out. In situations where they cycle frequently, a switch can
wear out in a few years.

No sump pump will pump *all* the water out of the sump. First, it's
not good for them to run dry. Second, the inlet is always raised a
bit to prevent sucking up too much muck.

HTH,

Paul F.
  #3   Report Post  
Posted to alt.home.repair
sid sid is offline
external usenet poster
 
Posts: 109
Default Sump Pump Problems

On Aug 10, 8:14*pm, Paul Franklin
wrote:
On Wed, 10 Aug 2011 16:27:38 -0700 (PDT), sid
wrote:





Testing the sump pump I discovered that the pump did not function.
The sump pump that we have is less the 6 yrs old, but we discovered
during testing that it was not working.


Testing: *poured a 5 gallon bucket of water into the sump.


1.) *The pump did nothing.
Took stick and slapped the float switch. *After 3 knocks the pump
kicked on.


2.) *Then I discovered that the pump was spinning, but failed to pump
any water.
Started to remove pump by loosening the hose clamps, when I herd it
suck some air.
Hearing this, I plugged the pump back in and it kicked on and emptied
the sump down past the float. (not entirely empty)


3.) *Poured another bucket of water in and this time it behaved
correctly.


Why did the pump act this way ? *Do I need to replace the float switch
or the pump ? *why did the air lock keep the pump from functioning ?


Pump: Zoeller M53 - 1/3 HP Cast Iron Submersible
(at least that’s what it looks like, tag is too crusty to read).
The float switch is not what is pictured on the Zoeller site, its a
black cylinder about 2.5 in dia. and 2.5 in high mounted on an arm
next to the pump.


Thanks


First Air lock. *There should be a small (1/8 dia or less) hole
drilled in the outlet pipe a couple of inches up from the pump base.
This will prevent air lock. Water will shoot out the hole when the
pump is running; that's ok. *

As for why it didn't kick on, I'm guessing your pump doesn't run very
often and the switch contacts probably got a little corroded. *The
switch is designed to wipe the contacts slightly each cycle to keep
them clean, but if it doesn't run often they can fail this way.

Zoeller sells a replacement switch kit for the M53. *It's a bit tricky
to install because of the need to seal it well since it's under water
some times. *But I'll bet if you dump a bucket of water every month or
so to cycle the pump it will be fine.

Having said that, because the M53 uses a mechanical switch, they do
wear out. *In situations where they cycle frequently, a switch can
wear out in a few years.

No sump pump will pump *all* the water out of the sump. *First, it's
not good for them to run dry. *Second, the inlet is always raised a
bit to prevent sucking up too much muck.

HTH,

Paul F.- Hide quoted text -

- Show quoted text -


Paul, thanks for the reply.

Where should this hole be ? In the pump housing or in the PVC ?
Is it possible that its there but just clogged ?

Last year I saw a DIY article on TV that suggested that the float
switch be replaced every 2 years just as periodic maintence ?
Would you agree ?

Thanks




  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 156
Default Sump Pump Problems

On Thu, 11 Aug 2011 16:30:19 -0700 (PDT), sid
wrote:

On Aug 10, 8:14*pm, Paul Franklin
wrote:
On Wed, 10 Aug 2011 16:27:38 -0700 (PDT), sid
wrote:





snip

Paul, thanks for the reply.

Where should this hole be ? In the pump housing or in the PVC ?
Is it possible that its there but just clogged ?

Last year I saw a DIY article on TV that suggested that the float
switch be replaced every 2 years just as periodic maintence ?
Would you agree ?

Thanks


Hole goes in the PVC. You can probably download the M53 manual from
Zoeller web site. IIRC, they describe where to place the hole. It's
possible it's there and plugged up.

A lot of pumps have a completely separate float switch that has it's
own cord with a combination male and female plug and outlet. The male
part plugs into the power outlet and the cord from the pump plugs into
the back of the float switch plug. With this type it's trivial to
replace the float switch periodically.

The M53 has an integral float switch that is a little more of a hassle
to change because of the gasketing involved. But if you are fairly
handy you can handle it. I imagine you can download the instructions
for the switch replacement as well; don't remember if they are in the
manual. They do come with the switch kit of course.

If it were me, I'd test it once a month for a while. If you see a
repeat of the problem you had, then I'd change the switch. If it
doesn't act up during testing, I'd let it go and just test it every
month or so. But it also depends on what gets ruined if it fails. If
a lot would get ruined, I'd change the switch and even consider a
backup pump.

Good Luck,

Paul F.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Battery Powered Sump Pump Problems lagman Home Repair 5 July 19th 07 03:57 AM
Sump Pump Clunk After Backup Pump Install [email protected] Home Repair 6 April 19th 07 05:18 PM
Sump pump float switch: separate from pump? Marc_G Home Repair 4 January 15th 06 09:46 PM
Sump Pump vs. No Sump Pump (Questions) BroJack Home Repair 4 September 5th 04 06:56 PM
Specify/Install Sump Pit and Sump Pump Puddin' Man Home Repair 4 November 26th 03 03:59 PM


All times are GMT +1. The time now is 12:22 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"