staple gun for Romex?
anyone recommend one? Got to staple some wires that are run along
joists hidden under a whole mess of insulation, rather than pull it all up to use a hammer I thought I'd try one of those staple guns to see if it would work OK. Anyone recommend any one above the others, or are they all about the same? I'm looking for just a hand operated one, I'm not doing this professionally, just trying to save attic time during some home rewiring. I doubt the inspector will look up there, but I don't want to lie to him either and tell him that I've stapled stuff that I haven't. (original wiring was just laid over the top of the joists, but I don't like that. Everything I'm putting in, I'm drilling through and stapling along.) thanks, Nate -- replace "roosters" with "cox" to reply. http://members.cox.net/njnagel |
#2
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
On 5/28/2010 6:35 PM, Nate Nagel wrote:
anyone recommend one? Got to staple some wires that are run along joists hidden under a whole mess of insulation, rather than pull it all up to use a hammer I thought I'd try one of those staple guns to see if it would work OK. Anyone recommend any one above the others, or are they all about the same? I'm looking for just a hand operated one, I'm not doing this professionally, just trying to save attic time during some home rewiring. I doubt the inspector will look up there, but I don't want to lie to him either and tell him that I've stapled stuff that I haven't. (original wiring was just laid over the top of the joists, but I don't like that. Everything I'm putting in, I'm drilling through and stapling along.) thanks, Nate http://www.arrowfastener.com/products/application/wire/ someone mentioned T75 http://www.newtechindustries.com/new...75_stapler.htm |
#3
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
Nate Nagel wrote:
.... ... Everything I'm putting in, I'm drilling through and stapling along.) Absolutely, totally, unnecessary and a waste of effort... Only stapling needed and that does any thing useful at all is that within the required distance of boxes, etc., ... -- |
#4
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
On 05/28/2010 07:52 PM, dpb wrote:
Nate Nagel wrote: ... ... Everything I'm putting in, I'm drilling through and stapling along.) Absolutely, totally, unnecessary and a waste of effort... Only stapling needed and that does any thing useful at all is that within the required distance of boxes, etc., ... Right, but it's still hidden under three layers if fiberglas and a foot or so of cellulose. I can much more easily fit a staple gun in there than I can move all the insulation out of the way to swing a hammer. I'm replacing all the fixture boxes with fan rated boxes, rewiring *everything,* and adding hardwired smoke detectors, so there will be... um... something like 10-12 ceiling boxes all with several wires coming out of them, which are technically accessable as there's no attic floor (so I can't use the "old work" exception,) but in reality are not easily accessable at all, so anything that makes the job easier would be welcome. And a staple or two in the middle of the runs (it's a small house, despite the large number of rooms/hallways/boxes, so it wouldn't be much more than that) wouldn't be that much of an impossibility. I'm also going to add a few receps in two of the bedrooms, but I haven't gotten that far yet. So far I have only completely rewired one bedroom, done the other one save for the receps, and properly wired one light in one hallway. So I've still got about half the second floor to rewire and haven't even started on the smokes yet. One of these days I'm going to have to get back at it and just do it... I bought all the materials save for the smokes but haven't got my lazy ass back up into the attic in a while. nate -- replace "roosters" with "cox" to reply. http://members.cox.net/njnagel |
#5
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
In article , Nate Nagel wrote:
On 05/28/2010 07:52 PM, dpb wrote: Nate Nagel wrote: ... ... Everything I'm putting in, I'm drilling through and stapling along.) Absolutely, totally, unnecessary and a waste of effort... Only stapling needed and that does any thing useful at all is that within the required distance of boxes, etc., ... Right, but it's still hidden under three layers if fiberglas and a foot or so of cellulose. I can much more easily fit a staple gun in there than I can move all the insulation out of the way to swing a hammer. Which is the only reason I can imagine for using one. I bought the Gardner-Bender stapler they sell at the Borg, and I am *not* impressed. It probably works better on new construction... but on the 55-year-old pine joists in my house, it won't sink a staple deep enough to meet the Code's requirements that the cable be "secured" to the framing. |
#6
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
On 5/28/2010 5:35 PM, Nate Nagel wrote:
anyone recommend one? Got to staple some wires that are run along joists hidden under a whole mess of insulation, rather than pull it all up to use a hammer I thought I'd try one of those staple guns to see if it would work OK. Anyone recommend any one above the others, or are they all about the same? I'm looking for just a hand operated one, I'm not doing this professionally, just trying to save attic time during some home rewiring. I doubt the inspector will look up there, but I don't want to lie to him either and tell him that I've stapled stuff that I haven't. (original wiring was just laid over the top of the joists, but I don't like that. Everything I'm putting in, I'm drilling through and stapling along.) thanks, Nate I have an Arrow T-something romex stapler. The inspector failed the wiring in my garage because of it; he said the problem was they weren't UL listed. I showed him the box with the UL label and that just ****ed him off. Bob |
#7
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
On 05/28/2010 09:17 PM, Doug Miller wrote:
In , Nate wrote: On 05/28/2010 07:52 PM, dpb wrote: Nate Nagel wrote: ... ... Everything I'm putting in, I'm drilling through and stapling along.) Absolutely, totally, unnecessary and a waste of effort... Only stapling needed and that does any thing useful at all is that within the required distance of boxes, etc., ... Right, but it's still hidden under three layers if fiberglas and a foot or so of cellulose. I can much more easily fit a staple gun in there than I can move all the insulation out of the way to swing a hammer. Which is the only reason I can imagine for using one. I bought the Gardner-Bender stapler they sell at the Borg, and I am *not* impressed. It probably works better on new construction... but on the 55-year-old pine joists in my house, it won't sink a staple deep enough to meet the Code's requirements that the cable be "secured" to the framing. hmm... my house is older than yours... I still am tempted to try it just because I think that if I have to go back and hand staple all the wire I've already pulled that it won't get done. A quick google seemed to indicate that both the Arrow T-72 and T-75 staplers might be what I'm seeking... anyone know what the difference between the two might be? nate -- replace "roosters" with "cox" to reply. http://members.cox.net/njnagel |
#8
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
In article ,
zxcvbob wrote: I have an Arrow T-something romex stapler. The inspector failed the wiring in my garage because of it; he said the problem was they weren't UL listed. I showed him the box with the UL label and that just ****ed him off. Bob So did you have to kill him? |
#9
Posted to alt.home.repair
|
|||
|
|||
staple gun for Romex?
On 5/29/2010 8:59 PM, Smitty Two wrote:
In , wrote: I have an Arrow T-something romex stapler. The inspector failed the wiring in my garage because of it; he said the problem was they weren't UL listed. I showed him the box with the UL label and that just ****ed him off. Bob So did you have to kill him? All the wiring was exposed and it wasn't that many staples, so I pulled them and replaced with plastic ones. (it was easier than killing him -- or asking for a ruling from a supervisor.) If I would have been smart, I would have only had the breaker box, one light, one receptacle, and the welder circuit inspected. Then extended everything and added the new circuits after he left. Bob |