Default Relay on a boiler

Can I buy just the relay component or do I have to replace the whole
honeywell box on my boiler? Sometimes when the heat wants to go on it
keeps switching on and off very quickly just as the burners start to
light.
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 539
Default Relay on a boiler

" wrote in message
...
Can I buy just the relay component or do I have to replace the whole
honeywell box on my boiler? Sometimes when the heat wants to go on it
keeps switching on and off very quickly just as the burners start to
light.


Well, if you can ascertain that this problem is caused by a specific relay
on the board, then you *might* be able to add a relay.
Basically, afaict, there are a few variables:
1. the signal going to the relay coil
2. the coil of the board relay
3. the switching contacts of the relay.
4. loose connection on the board itself.

Sometimes the contacts start to go, and you can remedy the situation by
having these contacts control your external relay, which is a much lower
current.
I have, I believe, a combination of 3 and 4, where I added a new relay off
the board relay, and had to physically shim the pc board to force
mechanical/electrical contact of whatever had broken/cracked. goodgawd....

If it's (2), then you will have to do soldering on the board itself, to
attach the coil of your external relay.
If it's (1), then you have another problem, which may or may not be the
control unit -- it could be a sensor, loose connection, etc.

I can't imagine thumbnail-sized relays on a pc board being able to handle
10+ amp blowers. Thus, it's not a bad idea to add a decent external relay
from the gitgo, altho this can get cumbersome if the blower is multispeed.
I just use two speeds, high for the A/C, and low for heat, and physically
just switch the wires at season change.

The problem with stuff like this is that if you ever do require outside
service, and an alt.hvac-type beer-swilling tech looks at yer artwork, he
will likely exact a horrible revenge, price-wise.
--
EA


  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,331
Default Relay on a boiler

Existential Angst wrote:
" wrote in message
...
Can I buy just the relay component or do I have to replace the whole
honeywell box on my boiler? Sometimes when the heat wants to go on it
keeps switching on and off very quickly just as the burners start to
light.


Well, if you can ascertain that this problem is caused by a specific relay
on the board, then you *might* be able to add a relay.
Basically, afaict, there are a few variables:
1. the signal going to the relay coil
2. the coil of the board relay
3. the switching contacts of the relay.
4. loose connection on the board itself.

Sometimes the contacts start to go, and you can remedy the situation by
having these contacts control your external relay, which is a much lower
current.
I have, I believe, a combination of 3 and 4, where I added a new relay off
the board relay, and had to physically shim the pc board to force
mechanical/electrical contact of whatever had broken/cracked. goodgawd....


These things must be junk. About 7 years ago I also had one go bad just
when the warranty was up on a brand new boiler installation. Tap on the
box and it ran, so I thought simply enough I'd open it up and either
clean the contacts or resolder the bad connection. No luck at all. I
too ended up wedging something on the board to make it work.

If you decide to buy a new one, I'd look for other brands. Honeywell
has a problem!
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 539
Default Relay on a boiler

"Tony" wrote in message
...
Existential Angst wrote:
" wrote in message
...
Can I buy just the relay component or do I have to replace the whole
honeywell box on my boiler? Sometimes when the heat wants to go on it
keeps switching on and off very quickly just as the burners start to
light.


Well, if you can ascertain that this problem is caused by a specific
relay on the board, then you *might* be able to add a relay.
Basically, afaict, there are a few variables:
1. the signal going to the relay coil
2. the coil of the board relay
3. the switching contacts of the relay.
4. loose connection on the board itself.

Sometimes the contacts start to go, and you can remedy the situation by
having these contacts control your external relay, which is a much lower
current.
I have, I believe, a combination of 3 and 4, where I added a new relay
off the board relay, and had to physically shim the pc board to force
mechanical/electrical contact of whatever had broken/cracked.
goodgawd....


These things must be junk. About 7 years ago I also had one go bad just
when the warranty was up on a brand new boiler installation. Tap on the
box and it ran, so I thought simply enough I'd open it up and either clean
the contacts or resolder the bad connection. No luck at all. I too ended
up wedging something on the board to make it work.


I believe these are hairline cracks in the brittle plastic base. Wedge it
one way, you close the break. Wedge it the other way, you could open it
further.

A dilemma would exist if there were soldered/printed circuitry on *both*
sides of the board/break -- then, bending would *never* solve the problem!
You would have to be able to place the edges of the board under pure
compression. What a pita....

But for these companies, it's just mo' money and mo' money....


If you decide to buy a new one, I'd look for other brands. Honeywell has
a problem!


This happened to me on a Bryant furnase... don't know who makes their
board.

It is maddening, tho.
--
EA




  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,926
Default Relay on a boiler

On Feb 15, 11:48*am, " wrote:
Can I buy just the relay component or do I have to replace the whole
honeywell box on my boiler? *Sometimes when the heat wants to go on it
keeps switching on and off very quickly just as the burners start to
light.


Is the box a just a relay and transformer, mine is, but if its more
than that how do you know its the relay. I have several Honywell
relays maybe 50 yrs old working now, I have no idea how old really,
Honywell relays just work. If its just a relay start by checking the
voltage of it, there is a certain voltage and call a supply house or
honywell to see if its in spec, or google. Switching on and off sounds
like some saftey is cutting it out, check for loose connections,
safteys controll the whole boiler, gas valve, maybe flue damper, low
water etc. Once my pilot assembly got wet from a leaking pipe, a bit
of water never dried on some external wiring and kept it from firing.
I would make sure all connections to the main board are clean and
tight first, the Honywell relay sould outlast the boiler.
  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,473
Default Relay on a boiler


" wrote in message
...
Can I buy just the relay component or do I have to replace the whole
honeywell box on my boiler? Sometimes when the heat wants to go on it
keeps switching on and off very quickly just as the burners start to
light.


You need to find out what's causing the relay to chatter. It is very
unlikely that it is a faulty relay. When you say "Honeywell box", it gives
very little usable information, as Honeywell makes dozens of boiler
controls, some are just switching relays, but others are aquastat relays,
which have more components in them that could cause a relay chatter.
Sometimes boiler relay chatter is caused by a combination of very low
amperage , typically ice cube type relay, used in combination with a current
robbing charging circuit on the thermostat


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Honeywell CM927 - Multiple units and binding to a single boiler relay Tim S UK diy 2 September 28th 08 11:20 PM
How to locate the distributors of relay, relay socket, and switches? [email protected] Electronics Repair 0 May 10th 07 06:50 AM
Baxi Solo 3 Boiler clicking relay after pump overrun MARTINHOG UK diy 5 May 29th 06 10:20 PM
Protherm 100EC combi boiler relay limrickuk Home Repair 1 January 9th 06 05:01 PM
Protherm 100EC combi boiler relay limrickuk Home Repair 0 January 9th 06 03:06 PM


All times are GMT +1. The time now is 05:31 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"