I have a garage that is fed with a 3 wire feed from one pole transformer and
my house is same from a different pole transformer. Both locations have a
ground rod attached to the box. The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I bought
the house) Is this a possible ground problem? The cable eventually connects
the shield to the ground of each television in both locations. Saw a similar
post the other day that got me thinking.....

Roanin


  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 539
Default Electrical Question

http://www.CEEGYNY.ORG
"ROANIN" wrote in message
...
I have a garage that is fed with a 3 wire feed from one pole transformer
and my house is same from a different pole transformer. Both locations have
a ground rod attached to the box. The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I bought
the house) Is this a possible ground problem? The cable eventually connects
the shield to the ground of each television in both locations. Saw a
similar post the other day that got me thinking.....


Anything can happen with ground/hum, but methinks the solution is
dirt-simple, if there is a problem:
Connect both ground rods with a wire.
Proly not a bad idea even if there isn't a problem, if one ground is
superior to the other, which can easily be the case. Codes notwithstanding,
of course.
--
EA





Roanin



  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,567
Default Electrical Question

On Nov 6, 11:16*am, "ROANIN" wrote:
I have a garage that is fed with a 3 wire feed from one pole transformer and
my house is same from a different pole transformer. Both locations have a
ground rod attached to the box. *The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I bought
the house) Is this a possible ground problem? The cable eventually connects
the shield to the ground of each television in both locations. Saw a similar
post the other day that got me thinking.....

Roanin


You probably have a ground loop. Do you have a hum problem at any of
the tv locations? If not then I would not worry about it. If you do
then the correct solution is to get an isolator for one location. The
quick and dirty solution is to lift the ground at one location.

Ground loops often have a small differential voltage typically present
as 60 cycles. It's not dangerous but often gets into audio circuitry
which is designed to amplify anything between 20hz and 20khz.

Adding more ground connections seldom helps as they all must travel
some distance and that's the reason you have a problem.
  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,567
Default Electrical Question

On Nov 6, 2:04*pm, wrote:
On Fri, 6 Nov 2009 11:16:18 -0500, "ROANIN"
wrote:

I have a garage that is fed with a 3 wire feed from one pole transformer and
my house is same from a different pole transformer. Both locations have a
ground rod attached to the box. *The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I bought
the house) Is this a possible ground problem? The cable eventually connects
the shield to the ground of each television in both locations. Saw a similar
post the other day that got me thinking.....


Roanin


EA has the right answer, bond the ground electrode systems together.

When I was in the computer business we fixed a lot of problems this
way when networks spanned several buildings. A lightning strike will
resolve this ground shift through your TV if you don't.


That won't fix ground loop hum in audio.
  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 539
Default Electrical Question

wrote in message
...
On Fri, 6 Nov 2009 11:16:18 -0500, "ROANIN"
wrote:

I have a garage that is fed with a 3 wire feed from one pole transformer
and
my house is same from a different pole transformer. Both locations have a
ground rod attached to the box. The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I
bought
the house) Is this a possible ground problem? The cable eventually
connects
the shield to the ground of each television in both locations. Saw a
similar
post the other day that got me thinking.....

Roanin


EA has the right answer, bond the ground electrode systems together.


Do I get a prize???
--
EA



When I was in the computer business we fixed a lot of problems this
way when networks spanned several buildings. A lightning strike will
resolve this ground shift through your TV if you don't.





  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,331
Default Electrical Question

ROANIN wrote:
I have a garage that is fed with a 3 wire feed from one pole transformer and
my house is same from a different pole transformer. Both locations have a
ground rod attached to the box. The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I bought
the house) Is this a possible ground problem? The cable eventually connects
the shield to the ground of each television in both locations. Saw a similar
post the other day that got me thinking.....


Like was posted, if you have a hum you probably have a ground loop, if
not hum, don't worry about it. I worked on a friends entertainment
center for hours before finding that if, and only if the center bass
speaker for surround sound and the cable tv was hooked up, he would get
a real bad hum. I forget how I fixed it?
  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 57
Default Electrical Question


"Tony" wrote in message
...
ROANIN wrote:
I have a garage that is fed with a 3 wire feed from one pole transformer
and my house is same from a different pole transformer. Both locations
have a ground rod attached to the box. The cable TV is connected to both
sites using a splitter. ( This was installed by the cable company before
I bought the house) Is this a possible ground problem? The cable
eventually connects the shield to the ground of each television in both
locations. Saw a similar post the other day that got me thinking.....


Like was posted, if you have a hum you probably have a ground loop, if not
hum, don't worry about it. I worked on a friends entertainment center for
hours before finding that if, and only if the center bass speaker for
surround sound and the cable tv was hooked up, he would get a real bad
hum. I forget how I fixed it?


OK thanks for the replies. I have no problems right at the moment, was just
wanting to make sure it was safe. The ground rods are about 200 feet apart
FYI.


  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,417
Default Electrical Question

On Nov 6, 11:16*am, "ROANIN" wrote:
I have a garage that is fed with a 3 wire feed from one pole transformer and
my house is same from a different pole transformer. Both locations have a
ground rod attached to the box. *The cable TV is connected to both sites
using a splitter. ( This was installed by the cable company before I bought
the house) Is this a possible ground problem? The cable eventually connects
the shield to the ground of each television in both locations. Saw a similar
post the other day that got me thinking.....

Roanin


Stuff happens and this arrangement may makes stuff somewhat more
likely to happen.

A house may last your lifetime and never need the ground connection
that was provided for it. What happens if one day that ground is
called upon to do its duty and the only path it has is through your TV
set, cable box cable modem and various other equipment out in the
garage. For audio there are isolation transformers commercially
available made to handle the situation you describe. I dont know if
there is anything available to isolate a cable TV signal
commercially.Perhaps googling TV isolation transformer may return
something.

Jimmie
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Electrical Question Michael Dobony Home Repair 14 October 23rd 09 05:21 AM
Electrical question: What do I need? diy-newby UK diy 2 March 11th 08 11:39 PM
Electrical Question??? fish Home Repair 5 January 23rd 06 03:12 AM
Electrical question Jim Beaver Home Repair 13 August 3rd 05 09:18 PM
Electrical question Martin Pentreath UK diy 11 September 16th 04 03:05 PM


All times are GMT +1. The time now is 08:57 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"