moving steam radiator
I need to move a steam radiator about six feet from its current
location. This is a single pipe system with black pipe. The piping is all accessible in the basement. I have zero experience working with iron pipe, but I'm pretty good with copper. I know that part of the boiler plumbing is copper (the manifold coming out of the boiler). Is there any reason that I couldn't go back to a convenient joint, install a dielectric union, and finish the job in copper (with another dielectric union at the radiator end)? OK, I just went downstairs and took a look at the boiler installation. Where the iron steam pipes connect to the copper manifold, they used copper threaded adapters with no dielectric unions. Where the condensate pipe attaches, they used compression fitting , which, I guess could be an insulator, but since the steam pipes are tied together, I'd have no way to check that. So, is it possible that in a steam pipe, which is not under water all the time like the condensate pipe is, that you don't need dielectric isolation between iron and copper? This boiler was installed 24 years ago, and there's no visible sign of corrosion at these joints. I am aware of the slope requirements, and I have plenty of headroom to do that. I don't want to use iron because, as I said, I have zero experience with that. I don't have threading equipment, and even though I'll measure twenty times before I cut once, I don't have much confidence that everything will line up on the first try, and that's yet another trip to the supplier to get yet another piece of pipe threaded. |
#2
Posted to alt.home.repair
|
|||
|
|||
moving steam radiator
On Oct 5, 11:39*am, rangerssuck wrote:
I need to move a steam radiator about six feet from its current location. This is a single pipe system with black pipe. The piping is all accessible in the basement. I have zero experience working with iron pipe, but I'm pretty good with copper. I know that part of the boiler plumbing is copper (the manifold coming out of the boiler). Is there any reason that I couldn't go back to a convenient joint, install a dielectric union, and finish the job in copper (with another dielectric union at the radiator end)? Maybe because dielectric unions don't survive all that well with steam. snip So, is it possible that in a steam pipe, which is not under water all the time like the condensate pipe is, that you don't need dielectric isolation between iron and copper? This boiler was installed 24 years ago, and there's no visible sign of corrosion at these joints. snip If you go ironcoppercopperiron the electrolysis currents oppose one anther. No current flow, no corrosion. FWIW, cutting and threading black iron is harder work than copper, so you may want to get an estimate from a pro. But check tool rental places for a power threader/ cutter outfit. If the cost is reasonable, take it home and you could knock the job together in a couple of hours. Changing the materials in a 24year old installation that has worked perfectly all this time just doesn't seem like a good idea. The old mantra, "there are tricks in every trade" is at work here. And by the way, if you don't have a monster pipe wrench (depending on your pipe size, natch) put one on your shopping/renting list. Good luck. Joe |
#3
Posted to alt.home.repair
|
|||
|
|||
moving steam radiator
On Oct 5, 2:00*pm, Joe wrote:
On Oct 5, 11:39*am, rangerssuck wrote: I need to move a steam radiator about six feet from its current location. This is a single pipe system with black pipe. The piping is all accessible in the basement. I have zero experience working with iron pipe, but I'm pretty good with copper. I know that part of the boiler plumbing is copper (the manifold coming out of the boiler). Is there any reason that I couldn't go back to a convenient joint, install a dielectric union, and finish the job in copper (with another dielectric union at the radiator end)? Maybe because dielectric unions don't survive all that well with steam. snip So, is it possible that in a steam pipe, which is not under water all the time like the condensate pipe is, that you don't need dielectric isolation between iron and copper? This boiler was installed 24 years ago, and there's no visible sign of corrosion at these joints. snip If you go ironcoppercopperiron the electrolysis currents oppose one anther. No current flow, no corrosion. FWIW, cutting and threading black iron is harder work than copper, so you may want to get an estimate from a pro. But check tool rental places for a power threader/ cutter outfit. If the cost is reasonable, take it home and you could knock the job together in a couple of hours. Changing the materials in a 24year old installation that has worked perfectly all this time just doesn't seem like a good idea. The old mantra, "there are tricks in every trade" is at work here. And by the way, if you don't have a monster pipe wrench (depending on your pipe size, natch) put one on your shopping/renting *list. Good luck. Joe Given that the electrolysis cancels out and that copper is easier to work with than iron, AND that this is one radiator at the far end of a run, why WOULDN'T copper be a good idea? If I was in the mood for an adventure, I'd surely rent the tools and have at it, but I really just want to get this done without spending an arm and a leg (and a month). |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Steam radiator air vent help | Home Repair | |||
steam radiator connecting nut | Home Repair | |||
Have old steam radiator, want to turn it off | Home Repair | |||
steam radiator valve ? | Home Repair | |||
Steam Radiator - ID and Specs.? | Home Repair |