Default moving steam radiator

I need to move a steam radiator about six feet from its current
location. This is a single pipe system with black pipe. The piping is
all accessible in the basement.

I have zero experience working with iron pipe, but I'm pretty good
with copper. I know that part of the boiler plumbing is copper (the
manifold coming out of the boiler).

Is there any reason that I couldn't go back to a convenient joint,
install a dielectric union, and finish the job in copper (with another
dielectric union at the radiator end)?

OK, I just went downstairs and took a look at the boiler installation.
Where the iron steam pipes connect to the copper manifold, they used
copper threaded adapters with no dielectric unions. Where the
condensate pipe attaches, they used compression fitting , which, I
guess could be an insulator, but since the steam pipes are tied
together, I'd have no way to check that.

So, is it possible that in a steam pipe, which is not under water all
the time like the condensate pipe is, that you don't need dielectric
isolation between iron and copper? This boiler was installed 24 years
ago, and there's no visible sign of corrosion at these joints.

I am aware of the slope requirements, and I have plenty of headroom to
do that. I don't want to use iron because, as I said, I have zero
experience with that. I don't have threading equipment, and even
though I'll measure twenty times before I cut once, I don't have much
confidence that everything will line up on the first try, and that's
yet another trip to the supplier to get yet another piece of pipe
threaded.
  #2   Report Post  
Posted to alt.home.repair
Joe Joe is offline
external usenet poster
 
Posts: 2,837
Default moving steam radiator

On Oct 5, 11:39*am, rangerssuck wrote:
I need to move a steam radiator about six feet from its current
location. This is a single pipe system with black pipe. The piping is
all accessible in the basement.

I have zero experience working with iron pipe, but I'm pretty good
with copper. I know that part of the boiler plumbing is copper (the
manifold coming out of the boiler).

Is there any reason that I couldn't go back to a convenient joint,
install a dielectric union, and finish the job in copper (with another
dielectric union at the radiator end)?


Maybe because dielectric unions don't survive all that well with
steam.

snip


So, is it possible that in a steam pipe, which is not under water all
the time like the condensate pipe is, that you don't need dielectric
isolation between iron and copper? This boiler was installed 24 years
ago, and there's no visible sign of corrosion at these joints.


snip


If you go ironcoppercopperiron the electrolysis currents oppose
one anther. No current flow, no corrosion. FWIW, cutting and threading
black iron is harder work than copper, so you may want to get an
estimate from a pro. But check tool rental places for a power threader/
cutter outfit. If the cost is reasonable, take it home and you could
knock the job together in a couple of hours. Changing the materials in
a 24year old installation that has worked perfectly all this time just
doesn't seem like a good idea. The old mantra, "there are tricks in
every trade" is at work here. And by the way, if you don't have a
monster pipe wrench (depending on your pipe size, natch) put one on
your shopping/renting list. Good luck.

Joe
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 2,104
Default moving steam radiator

On Oct 5, 2:00*pm, Joe wrote:
On Oct 5, 11:39*am, rangerssuck wrote:

I need to move a steam radiator about six feet from its current
location. This is a single pipe system with black pipe. The piping is
all accessible in the basement.


I have zero experience working with iron pipe, but I'm pretty good
with copper. I know that part of the boiler plumbing is copper (the
manifold coming out of the boiler).


Is there any reason that I couldn't go back to a convenient joint,
install a dielectric union, and finish the job in copper (with another
dielectric union at the radiator end)?


Maybe because dielectric unions don't survive all that well with
steam.

snip
So, is it possible that in a steam pipe, which is not under water all
the time like the condensate pipe is, that you don't need dielectric
isolation between iron and copper? This boiler was installed 24 years
ago, and there's no visible sign of corrosion at these joints.
snip


If you go ironcoppercopperiron the electrolysis currents oppose
one anther. No current flow, no corrosion. FWIW, cutting and threading
black iron is harder work than copper, so you may want to get an
estimate from a pro. But check tool rental places for a power threader/
cutter outfit. If the cost is reasonable, take it home and you could
knock the job together in a couple of hours. Changing the materials in
a 24year old installation that has worked perfectly all this time just
doesn't seem like a good idea. The old mantra, "there are tricks in
every trade" is at work here. And by the way, if you don't have a
monster pipe wrench (depending on your pipe size, natch) put one on
your shopping/renting *list. Good luck.

Joe


Given that the electrolysis cancels out and that copper is easier to
work with than iron, AND that this is one radiator at the far end of a
run, why WOULDN'T copper be a good idea?

If I was in the mood for an adventure, I'd surely rent the tools and
have at it, but I really just want to get this done without spending
an arm and a leg (and a month).
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Steam radiator air vent help [email protected] Home Repair 1 December 3rd 06 05:06 PM
steam radiator connecting nut briand Home Repair 2 August 30th 06 02:57 AM
Have old steam radiator, want to turn it off [email protected] Home Repair 2 December 17th 05 11:40 PM
steam radiator valve ? anonomous Home Repair 8 October 26th 05 10:47 PM