Posted to alt.home.repair
|
|||
|
|||
![]()
I am doing a complete bathroom renovation. I wish to install two GFI
receptacles in a double box. The incomming wire is always hot and goes no further than the box in question. As there is already one existing GFI recptacle in place i can see how its wired. can i just pigtale its white and the new ones white to the incomming white and pigtale the current black and the new black to the incomming black and common the grounds |
#2
![]()
Posted to alt.home.repair
|
|||
|
|||
![]()
wrote in message
... I am doing a complete bathroom renovation. I wish to install two GFI receptacles in a double box. The incomming wire is always hot and goes no further than the box in question. As there is already one existing GFI recptacle in place i can see how its wired. can i just pigtale its white and the new ones white to the incomming white and pigtale the current black and the new black to the incomming black and common the grounds Why not install a regular (non GFI) duplex receptacle downstream of the existing GFI? |
#3
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() wrote in message ... I am doing a complete bathroom renovation. I wish to install two GFI receptacles in a double box. The incomming wire is always hot and goes no further than the box in question. As there is already one existing GFI recptacle in place i can see how its wired. can i just pigtale its white and the new ones white to the incomming white and pigtale the current black and the new black to the incomming black and common the grounds Yes or you can do as Peter suggested to save a little on the cost of an additional GFI. Put your pigtail wires from the second receptacle into the LOAD terminals on the first GFI. That will make the second receptacle GFI protected. The current code calls for a separate 20 amp circuit for the bathroom. |
#4
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() "John Grabowski" wrote in message ... wrote in message ... I am doing a complete bathroom renovation. I wish to install two GFI receptacles in a double box. The incomming wire is always hot and goes no further than the box in question. As there is already one existing GFI recptacle in place i can see how its wired. can i just pigtale its white and the new ones white to the incomming white and pigtale the current black and the new black to the incomming black and common the grounds Yes or you can do as Peter suggested to save a little on the cost of an additional GFI. Put your pigtail wires from the second receptacle into the LOAD terminals on the first GFI. That will make the second receptacle GFI protected. The current code calls for a separate 20 amp circuit for the bathroom. This is excellent advice but you will need to use the decora style duplex so that you can find a 2 gang cover to fit. -- Colbyt Please come visit www.househomerepair.com |
#5
![]()
Posted to alt.home.repair
|
|||
|
|||
![]() "Colbyt" wrote in message news ![]() "John Grabowski" wrote in message ... wrote in message ... I am doing a complete bathroom renovation. I wish to install two GFI receptacles in a double box. The incomming wire is always hot and goes no further than the box in question. As there is already one existing GFI recptacle in place i can see how its wired. can i just pigtale its white and the new ones white to the incomming white and pigtale the current black and the new black to the incomming black and common the grounds Yes or you can do as Peter suggested to save a little on the cost of an additional GFI. Put your pigtail wires from the second receptacle into the LOAD terminals on the first GFI. That will make the second receptacle GFI protected. The current code calls for a separate 20 amp circuit for the bathroom. This is excellent advice but you will need to use the decora style duplex so that you can find a 2 gang cover to fit. -- Colbyt Please come visit www.househomerepair.com They actually make two gang Decora/Duplex plates, although a two gang Decora/Decora plate would look more attractive |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Proper GFCI installation | Home Repair | |||
Proper Installation of Corrugated Pipe for Drainage Purposes | Home Repair | |||
proper window installation | Home Repair | |||
Proper Receptacles for 20 Amp Circuit | Home Repair | |||
Gutters--Proper installation question | Home Repair |