We have lived in this house about 9 years, and have found another
problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? |
#2
Posted to alt.home.repair
|
|||
|
|||
strange voltage
"bgtcars" wrote in message ... We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? On wiring that has been disconnected, but is still near a live circuit. Don't use your meter, but instead connect a light bulb to the wires and see what happens. |
#3
Posted to alt.home.repair
|
|||
|
|||
strange voltage
bgtcars wrote:
We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? It may be that there is no direct connection here. The two wires you are measuring may have been abandoned but since they are located along with other energized wires you may be measuring a capacitive voltage divider. I'd guess that you are using a high impedance volt meter that doesn't load the circuit. Measure with a low impedance volt meter, or load the circuit slightly...perhaps with a small load like a night-lite (4 or 7 watts) clipped between the two wires you are measuring and the measured voltage will probably drop to zero. |
#4
Posted to alt.home.repair
|
|||
|
|||
strange voltage
On Sun, 30 Mar 2008 10:14:37 -0400, Boden wrote:
bgtcars wrote: We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? It may be that there is no direct connection here. The two wires you are measuring may have been abandoned but since they are located along with other energized wires you may be measuring a capacitive voltage divider. I'd guess that you are using a high impedance volt meter that doesn't load the circuit. Measure with a low impedance volt meter, or load the circuit slightly...perhaps with a small load like a night-lite (4 or 7 watts) clipped between the two wires you are measuring and the measured voltage will probably drop to zero. It'd be nice if those meters came with a button that applies a small load. You could press it and see if the voltage drops significantly. -- Mark Lloyd http://notstupid.laughingsquid.com "Never underestimate the power of stupid people in large groups" |
#5
Posted to alt.home.repair
|
|||
|
|||
strange voltage
On Mar 30, 11:00�am, Mark Lloyd wrote:
On Sun, 30 Mar 2008 10:14:37 -0400, Boden wrote: bgtcars wrote: We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? It may be that there is no direct connection here. �The two wires you are measuring may have been abandoned but since they are located along with other energized wires you may be measuring a capacitive voltage divider. �I'd guess that you are using a high impedance volt meter that doesn't load the circuit. �Measure with a low impedance volt meter, or load the circuit slightly...perhaps with a small load like a night-lite (4 or 7 watts) clipped between the two wires you are measuring and the measured voltage will probably drop to zero. It'd be nice if those meters came with a button that applies a small load. You could press it and see if the voltage drops significantly. -- Mark Lloydhttp://notstupid.laughingsquid.com "Never underestimate the power of stupid people in large groups"- Hide quoted text - - Show quoted text - bet a digital meter was used, way too sensitive. use a light bulb with digital meter at same time.............. |
#6
Posted to alt.home.repair
|
|||
|
|||
strange voltage
bgtcars wrote:
We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? do you get a dial tone on it? |
#7
Posted to alt.home.repair
|
|||
|
|||
strange voltage
Mark Lloyd wrote:
On Sun, 30 Mar 2008 10:14:37 -0400, Boden wrote: bgtcars wrote: We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? It may be that there is no direct connection here. The two wires you are measuring may have been abandoned but since they are located along with other energized wires you may be measuring a capacitive voltage divider. I'd guess that you are using a high impedance volt meter that doesn't load the circuit. Measure with a low impedance volt meter, or load the circuit slightly...perhaps with a small load like a night-lite (4 or 7 watts) clipped between the two wires you are measuring and the measured voltage will probably drop to zero. It'd be nice if those meters came with a button that applies a small load. You could press it and see if the voltage drops significantly. Yes, and they'd be more usefull when testing batteries. |
#8
Posted to alt.home.repair
|
|||
|
|||
strange voltage
On Mar 30, 10:16*am, bgtcars wrote:
We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? Obviously limited knowledge of electricity! Not only that; the the type of wiring, method of measuring and type of device (meter?) used is not specified! For example; is it an 'induced' voltage due to disconnected wires running through the same walls and possibly alongside working electrical wiring? The suggestion that maybe it's an old telephone circuit can not be discounted. Or maybe a disconnected speaker citcuit? Insufficient info. to comment. Just hooking up a meter to some unknown wiring is a meaningless exercise. |
#9
Posted to alt.home.repair
|
|||
|
|||
strange voltage
terry wrote:
On Mar 30, 10:16 am, bgtcars wrote: We have lived in this house about 9 years, and have found another problem. Pulled a patch off wall in one back room that we never used and found wiring that was stubed out, looked like a fixture may have been there . checked voltage and it was 39.4 there is no switch controling it that I can find. The light switch in the room is normal and works good, where could you get that kind of voltage on a line when the line voltage is 220 /110 service? Obviously limited knowledge of electricity! Not only that; the the type of wiring, method of measuring and type of device (meter?) used is not specified! For example; is it an 'induced' voltage due to disconnected wires running through the same walls and possibly alongside working electrical wiring? The suggestion that maybe it's an old telephone circuit can not be discounted. Or maybe a disconnected speaker citcuit? Insufficient info. to comment. Just hooking up a meter to some unknown wiring is a meaningless exercise. Hi, Specially if the meter is digital type. Some cases analog meter is more useful. |
#10
Posted to alt.home.repair
|
|||
|
|||
strange voltage
On Sun, 30 Mar 2008 15:21:53 -0400, Boden wrote:
Mark Lloyd wrote: On Sun, 30 Mar 2008 10:14:37 -0400, Boden wrote: It'd be nice if those meters came with a button that applies a small load. You could press it and see if the voltage drops significantly. Yes, and they'd be more usefull when testing batteries. I do have one digital meter with settings for voltage testing, and two other settings for battery testing. I forget the brand. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Strange Voltage Outlets / 347 volts ????? | Home Repair | |||
Strange voltage reading at unknown switch | Home Repair | |||
Strange voltage reading at unknown switch | Home Repair | |||
strange electrical AC problem (high/low voltage) | Home Ownership | |||
strange electrical AC problem (high/low voltage) | Home Repair |