Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 65
Default Sewage pump vent stack

I put in a new toilet and sink in basement with sewage pump. Drain
lines are in no problem, but was planning to run vent stack just above
utility sink on first floor and tie in there - but discovered that
second floor sink drains into same line. Then planned on venting out
of garage and hiding unsightly exhaust behind some bushes, but window
on side of garage does not allow for 10' horizontal spacing as
required, and inspector said it needs to be 10' above grade if going
above window on sidewall vent and garage is only 9.5' high. So, what
options are left? I can try to find another vent to tap into from
another sink, but that might mean cutting quite a bit of drywall and/
or cabinet backing. And I would hate to incur the expense and
potential leakage of going through roof. Any other ideas?
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 36
Default Sewage pump vent stack


wrote in message
...
I put in a new toilet and sink in basement with sewage pump. Drain
lines are in no problem, but was planning to run vent stack just above
utility sink on first floor and tie in there - but discovered that
second floor sink drains into same line. Then planned on venting out
of garage and hiding unsightly exhaust behind some bushes, but window
on side of garage does not allow for 10' horizontal spacing as
required, and inspector said it needs to be 10' above grade if going
above window on sidewall vent and garage is only 9.5' high. So, what
options are left? I can try to find another vent to tap into from
another sink, but that might mean cutting quite a bit of drywall and/
or cabinet backing. And I would hate to incur the expense and
potential leakage of going through roof. Any other ideas?



studor valve

http://www.studor.com/index2.htm


  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 65
Default Sewage pump vent stack

Yes, I thought of an AAV, but the NSPC specifically calls out that
these are not permitted for sewage ejector pumps. The other codes
don't appear to specifically call it out, but I don't want to take the
chance that it would be reason to fail my inspection. I have a call
into the inpsector, so we'll see what he says.
  #4   Report Post  
Posted to alt.home.repair
EXT EXT is offline
external usenet poster
 
Posts: 1,661
Default Sewage pump vent stack

Through the roof is simple, cheap and easy. Pre-manufactured rubber roof
flashing is inexpensive and completely reliable if installed correctly,
which is easy to do.

wrote in message
...
I put in a new toilet and sink in basement with sewage pump. Drain
lines are in no problem, but was planning to run vent stack just above
utility sink on first floor and tie in there - but discovered that
second floor sink drains into same line. Then planned on venting out
of garage and hiding unsightly exhaust behind some bushes, but window
on side of garage does not allow for 10' horizontal spacing as
required, and inspector said it needs to be 10' above grade if going
above window on sidewall vent and garage is only 9.5' high. So, what
options are left? I can try to find another vent to tap into from
another sink, but that might mean cutting quite a bit of drywall and/
or cabinet backing. And I would hate to incur the expense and
potential leakage of going through roof. Any other ideas?



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Sewage pump question lp13-30 Home Repair 7 December 22nd 07 02:36 AM
Sewage ejector pump for cabana? davidwat Home Repair 1 December 13th 07 08:39 PM
Grinder pump vs. sewage pump for basement [email protected] Home Repair 3 November 11th 07 10:57 PM
sewage ejector toilet vent installation wannabe Home Repair 7 December 5th 05 10:42 PM