Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.building.construction,alt.home.repair
external usenet poster
 
Posts: 1,066
Default split ac unit install question

You can't hurt anything about the wall unless you cut out framing
lumber. There really is nothing about the installation that even
fastens to the wall unless you create something for your own
purposes. There are two copper lines involved and probably power
and control wiring. It might be neater and cleaner to install one
sleeve though the wall between studs that is well caulked and
sealed. Send the lines and conduits through the sleeve - grow
foam with a little paint or caulk on the outside to seal the
lines.

--
______________________________
Keep the whole world singing . . . .
DanG (remove the sevens)




"Joe" wrote in message
...

not sure if this is the right forum.

i'm planning on installing a "split" air conditioning
and heating unit in my attached 2 car garage (presently
insulated but unconditioned/unheated).

the side i'd like to mount the air handler/cooling/heating
unit on is a load bearing wall.

i might be worried over nothing, but since it is a load
bearing wall, would mounting that "split" part of the system
to the studs on that wall create any potential structural
problems. i don't see how it would, but thought i'd get
some opinions.

the other question is, in order to run the lines to that
split unit to the outside condensor/fan, we need to drill
openings in that load bearing wall. so if you go in between
the studs, it should be fine - right ? - how would a
reputable contractor seal up these holes after they've
run the lines ? (since the Tyvek, and CDX plyscore thats
under the vinyl siding is compromised by the hole)...is
it just a matter of injecting some sealing foam/compound?

thanks in advance for any responses.




  #2   Report Post  
Posted to alt.building.construction,alt.home.repair
Joe Joe is offline
external usenet poster
 
Posts: 3
Default split ac unit install question


not sure if this is the right forum.

i'm planning on installing a "split" air conditioning
and heating unit in my attached 2 car garage (presently
insulated but unconditioned/unheated).

the side i'd like to mount the air handler/cooling/heating
unit on is a load bearing wall.

i might be worried over nothing, but since it is a load
bearing wall, would mounting that "split" part of the system
to the studs on that wall create any potential structural
problems. i don't see how it would, but thought i'd get
some opinions.

the other question is, in order to run the lines to that
split unit to the outside condensor/fan, we need to drill
openings in that load bearing wall. so if you go in between
the studs, it should be fine - right ? - how would a
reputable contractor seal up these holes after they've
run the lines ? (since the Tyvek, and CDX plyscore thats
under the vinyl siding is compromised by the hole)...is
it just a matter of injecting some sealing foam/compound?

thanks in advance for any responses.


  #3   Report Post  
Posted to alt.building.construction,alt.home.repair
external usenet poster
 
Posts: 5,823
Default split ac unit install question


"Joe" wrote in message

i might be worried over nothing, but since it is a load
bearing wall, would mounting that "split" part of the system
to the studs on that wall create any potential structural
problems. i don't see how it would, but thought i'd get
some opinions.


Nope, it can take quite a bit.



it should be fine - right ? - how would a
reputable contractor seal up these holes after they've
run the lines ? (since the Tyvek, and CDX plyscore thats
under the vinyl siding is compromised by the hole)...is
it just a matter of injecting some sealing foam/compound?


Right. I'd use spray foam.


  #4   Report Post  
Posted to alt.building.construction,alt.home.repair
external usenet poster
 
Posts: 48
Default split ac unit install question


the other question is, in order to run the lines to that
split unit to the outside condensor/fan, we need to drill
openings in that load bearing wall. so if you go in between
the studs, it should be fine - right ? - how would a
reputable contractor seal up these holes after they've
run the lines ?



The unit will come with a sleeve that goes through the wall. The one I
installed required a 2" hole

--
Dennis

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Which central split pack unit should I buy? [email protected] Home Repair 7 July 11th 07 07:56 AM
Heating a room with split aircon unit R.P.McMurphy UK diy 20 March 11th 07 07:40 PM
Air Conditioner (Split Unit) Compressor Location Gripper UK diy 19 September 28th 06 10:30 AM
RCD TRIPS ON MOST CIRCUITS ON NEW SPLIT LOAD CONSUMER UNIT KevCompton UK diy 20 March 15th 06 12:32 PM
Volex or GE split load consumer unit? Kalico UK diy 4 November 4th 03 12:25 PM


All times are GMT +1. The time now is 07:36 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"