Default What is this stuff above sole plate?

I need to run some new wiring up from the basement into the wall. Is this
concrete that the wiring is currently run through? It's not very dense but
very hard. Instead of drilling another hole I was thinking I could cut the
armored cable from the top and then just rip it out from the bottom. Could I
then just run the romex through that hole.

Picture
http://s107.photobucket.com/albums/m...t=IMG_1756.jpg

Thanks
Dante



  #2   Report Post  
Posted to alt.home.repair
dpb dpb is offline
external usenet poster
 
Posts: 12,595
Default What is this stuff above sole plate?

Dante wrote:
I need to run some new wiring up from the basement into the wall. Is this
concrete that the wiring is currently run through? It's not very dense but
very hard. Instead of drilling another hole I was thinking I could cut the
armored cable from the top and then just rip it out from the bottom. Could I
then just run the romex through that hole.


Looks like concrete, but don't understand the "not dense" part...

If you don't need the existing cable, if it will come out, sure.

If you used a proper abrasion collar at the ends you could probably use
the existing armored as a sleeve/conduit for the new for such a short
distance.

--
  #3   Report Post  
Posted to alt.home.repair
RBM RBM is offline
external usenet poster
 
Posts: 1,690
Default What is this stuff above sole plate?

It appears that you have an older house with balloon framing. That masonry
is a fire stop. You can chisel out a bit of the masonry and fish a cable
right up the wall. The only reason you might consider removing that cable,
is if it's going to the same box you want to run a new cable into. That
cable will probably be stapled inside the wall, so it may not come out
easily or intact.




"Dante" wrote in message
...
I need to run some new wiring up from the basement into the wall. Is this
concrete that the wiring is currently run through? It's not very dense but
very hard. Instead of drilling another hole I was thinking I could cut the
armored cable from the top and then just rip it out from the bottom. Could
I then just run the romex through that hole.

Picture
http://s107.photobucket.com/albums/m...t=IMG_1756.jpg

Thanks
Dante





  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,934
Default What is this stuff above sole plate?


"RBM" rbm2(remove wrote in message
...
It appears that you have an older house with balloon framing. That masonry
is a fire stop. You can chisel out a bit of the masonry and fish a cable
right up the wall. The only reason you might consider removing that cable,
is if it's going to the same box you want to run a new cable into. That
cable will probably be stapled inside the wall, so it may not come out
easily or intact.



I agree with RBM. That concrete is probably a firestop and does not go all
the way up the wall. If you can get a fish tape along side the existing
cable you may be able to determine how high you can go. If it is balloon
framing you could probably snake up to the attic. Patch that hole up when
you are finished running your wires.





"Dante" wrote in message
...
I need to run some new wiring up from the basement into the wall. Is this
concrete that the wiring is currently run through? It's not very dense

but
very hard. Instead of drilling another hole I was thinking I could cut

the
armored cable from the top and then just rip it out from the bottom.

Could
I then just run the romex through that hole.

Picture

http://s107.photobucket.com/albums/m...t=IMG_1756.jpg

Thanks
Dante






  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1
Default What is this stuff above sole plate?

On Sun, 8 Jul 2007 09:39:21 -0400, "Dante" wrote:

I need to run some new wiring up from the basement into the wall. Is this
concrete that the wiring is currently run through? It's not very dense but
very hard. Instead of drilling another hole I was thinking I could cut the
armored cable from the top and then just rip it out from the bottom. Could I
then just run the romex through that hole.

Picture
http://s107.photobucket.com/albums/m...t=IMG_1756.jpg

Thanks
Dante



Some people seem to think that all older wiring is bad. There is
likely nothing wrong with that armored cable (AC). If you need more
outlets, run another cable and add more outlets. But why are you
trying to rip out the old AC? It's stapled inside the wall, so
without ripping walls apart you wont get it out. If it's a #14 and
you need some 20A outlets, just leave the 15A outlet and install more
outlets nearby with #12 wire. More is better (meaning more outlets),
but more work is NOT better, and you'll have more work trying to rip
out that AC. If you dont want to use that AC at all. just disconnect
it and leave it be (or cut off the exposed end in the basement). Then
run new wiring thru new holes. Yeah, you will likely have to chisel
away some cement.


  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 9
Default What is this stuff above sole plate?

Some people seem to think that all older wiring is bad. There is
likely nothing wrong with that armored cable (AC).


Most of the AC in the house is in very good condition and I was able to get
a ground through the armor on almost all outlets. But for some reason the
armor is not grounded at this outlet and the two that come after it. The
section is grounded that you see in the picture so the ground is lost in the
wall. Maybe the cable is damaged. The outlet is only a few inches above that
so I just feel safer knowing that I'll have a good low resistance ground
with new romex.


  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 1,934
Default What is this stuff above sole plate?


"Dante" wrote in message
...
Some people seem to think that all older wiring is bad. There is
likely nothing wrong with that armored cable (AC).


Most of the AC in the house is in very good condition and I was able to

get
a ground through the armor on almost all outlets. But for some reason the
armor is not grounded at this outlet and the two that come after it. The
section is grounded that you see in the picture so the ground is lost in

the
wall. Maybe the cable is damaged. The outlet is only a few inches above

that
so I just feel safer knowing that I'll have a good low resistance ground
with new romex.



Maybe the cable slipped out of the box clamp or connector. Have you looked
inside of the outlet box to see if there is armor showing? If not, you be
able to loosen the clamp and pull the cable and armor into the box.

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
FS in Alachua/Gainesville FL: huge volume shop stuff, tools supplieshardwares, other "guy stuff", 1, some, or all - PICKUP preferred dave Woodworking 0 January 30th 07 04:31 PM
Use of Gas Logs during the night? and as a sole heat source.. Stevey Sandlin Home Repair 6 September 25th 06 04:39 PM
Fixing a sole plate to exterior concrete slab Chris Bacon UK diy 7 May 18th 06 02:26 PM
"Old school" method of attaching sole plate to concrete vs. Tapcons. Sean M Home Repair 8 February 2nd 06 11:27 AM
BBQ Plate? BIGEYE Metalworking 40 February 15th 05 10:53 PM


All times are GMT +1. The time now is 05:35 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"