Jet Pump fast cycle
I pull water from a lake and pump it up to my cottage. For some
reason, my pump has started short cycling. I changed the pressure switch, and the pressure tank is fully charged (about 38 lbs). It is primed. If I open the prime port and turn the pump in it shoots water high into the air - getting water is not the problem. When the pump comes on, it quickly builds pressure to 40 lbs and then shuts off, pressure immediatley drops to 20, pump comes on, then off very rapidly. Would a leak in the line between the jet pump and the house cause this? I am thinking it might have frozen and split.... |
#2
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
You need to charge the tank with the pump off and a faucet open. Sounds
like you're water logged. -- Steve Barker wrote in message oups.com... I pull water from a lake and pump it up to my cottage. For some reason, my pump has started short cycling. I changed the pressure switch, and the pressure tank is fully charged (about 38 lbs). It is primed. If I open the prime port and turn the pump in it shoots water high into the air - getting water is not the problem. When the pump comes on, it quickly builds pressure to 40 lbs and then shuts off, pressure immediatley drops to 20, pump comes on, then off very rapidly. Would a leak in the line between the jet pump and the house cause this? I am thinking it might have frozen and split.... |
#3
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
On May 10, 10:56 pm, "Steve Barker"
wrote: You need to charge the tank with the pump off and a faucet open. Sounds like you're water logged. Pressure tank is charged to 38 Lbs, and not heavy - so assume not water logged. That's why I was suspecting a leak. |
#4
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
On May 10, 8:06 pm, wrote:
On May 10, 10:56 pm, "Steve Barker" wrote: You need to charge the tank with the pump off and a faucet open. Sounds like you're water logged. Pressure tank is charged to 38 Lbs, and not heavy - so assume not water logged. That's why I was suspecting a leak. Check valve? Tom |
#5
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
wrote in message oups.com... I pull water from a lake and pump it up to my cottage. For some reason, my pump has started short cycling. I changed the pressure switch, and the pressure tank is fully charged (about 38 lbs). It is primed. If I open the prime port and turn the pump in it shoots water high into the air - getting water is not the problem. When the pump comes on, it quickly builds pressure to 40 lbs and then shuts off, pressure immediatley drops to 20, pump comes on, then off very rapidly. Would a leak in the line between the jet pump and the house cause this? I am thinking it might have frozen and split.... Between the pump and the house or between the pump and the foot valve. Or the foot valve (if any) could be bad. Bob |
#6
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
|
#7
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
On May 10, 7:44 pm, wrote:
I pull water from a lake and pump it up to my cottage. For some reason, my pump has started short cycling. I changed the pressure switch, and the pressure tank is fully charged (about 38 lbs). It is primed. If I open the prime port and turn the pump in it shoots water high into the air - getting water is not the problem. When the pump comes on, it quickly builds pressure to 40 lbs and then shuts off, pressure immediatley drops to 20, pump comes on, then off very rapidly. Would a leak in the line between the jet pump and the house cause this? I am thinking it might have frozen and split.... Others have covered all the points so I will just wrap it all up in one: 1. Your pre-charge tank pressure is too high. Drain tank and re- charge to 20 psi. If the problem stillpersists: 2. Leak? Quit possible, in the input line or a footvalve or check valve. You can install a new checkvalve just prior to the tank. It will work just fine. I have assumed (I know, I know) that the pressure tank is in the cottage. If it is co-located with the pump then the leak could be on the house side and in that case you will have to find and fix it. Harry K |
#8
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
On May 10, 7:44 pm, wrote:
I pull water from a lake and pump it up to my cottage. For some reason, my pump has started short cycling. I changed the pressure switch, and the pressure tank is fully charged (about 38 lbs). It is primed. If I open the prime port and turn the pump in it shoots water high into the air - getting water is not the problem. When the pump comes on, it quickly builds pressure to 40 lbs and then shuts off, pressure immediatley drops to 20, pump comes on, then off very rapidly. Would a leak in the line between the jet pump and the house cause this? I am thinking it might have frozen and split.... Others have covered the problem and solution. I am just wrapping it all up in one: I am assuming the pressure tank is in the house: 1. Your pre-charge in the tank is too high. Drain tank and re-charge to 18psi. If that doesn't cure it, then you have a leak. 2. The leak will be either in the inlet pipe to the tank. It can be a broken pipe, a bad footvalve or a check valve. You can fix the problem by installing a new checkvalve just prior to the tank. The system will work just fine as long as the pump doesn't loose prime but if it is a broken pipe you will be pumping a lot of water out of it every time the tank fills. May not matter Now if the tank is co-located with the pump, then you have to find the leak and fix it. Start witht he foot valve. If it is in the pipe going to the cottage, you'll have to dig it up and fix. Harry K |
#9
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
|
#10
Posted to alt.home.repair
|
|||
|
|||
Jet Pump fast cycle
On May 11, 8:49 pm, wrote:
On 10 May 2007 20:06:43 -0700, wrote: On May 10, 10:56 pm, "Steve Barker" wrote: You need to charge the tank with the pump off and a faucet open. Sounds like you're water logged. Pressure tank is charged to 38 Lbs, and not heavy - so assume not water logged. That's why I was suspecting a leak. It's easy to detect a leak. Shut off everything in the house. Preferably shut off the main valve in the house (if there is one). Pump up to full pressure, then watch the pressure gauge. If it slowly drops, you got a small leak. If it drops quickly, you got a big leak. I also think you are waterlogged. Empty the tank completely and drain the lines. NOW check the tank air pressure. Close all drain valves and restart the pump. The pressure in the bladder should be 2lbs less than what ever you want the pump to turn on at. Check the air valve if you have water replace the tank |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Why would well pump cycle on and off every second? | Home Ownership | |||
CH pump - fast or slow? | UK diy | |||
CH pump - fast or slow? | UK diy | |||
CH pump - fast or slow? | UK diy | |||
Heat Pump defrost cycle?? | Home Repair |