You need to charge the tank with the pump off and a faucet open. Sounds
like you're water logged.
Pressure tank is charged to 38 Lbs, and not heavy - so assume not
water logged. That's why I was suspecting a leak.
It's easy to detect a leak. Shut off everything in the house.
Preferably shut off the main valve in the house (if there is one).
Pump up to full pressure, then watch the pressure gauge. If it slowly
drops, you got a small leak. If it drops quickly, you got a big leak.
I also think you are waterlogged. Empty the tank completely and drain
the lines. NOW check the tank air pressure. Close all drain valves
and restart the pump.