I had to relocate some plumbing copper pipes in by basement. They are
3/4 pipes. They were in a difficult place and there was some moisture
in the line. I cleaned the joints well and used the flux paste like
normal, but since there was moisture in the line (dripping water in
the line) the joints took a long time to heat up. I got the solder
flowing into them eventually and I used a good amount, but they look
like crap and are burnt looking too. On some of them I can see the
solder looks like it has gaps in it at the seam.

Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? or is it that if it holds water,
it is fine and will last as long as a nice looking joint. I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.

Thanks.

  #2   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 5,823
Default do sloppy copper joints fail easier?


wrote in message

Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? or is it that if it holds water,
it is fine and will last as long as a nice looking joint. I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.


Yes, it is possible. If you got a good bond of solder inside the joint, it
will last forever. The crappy look may be just on the outside. Keep an eye
on it though. If you have to do it over, use a hotter torch rather than
play on the joint with a little propane job. You sometimes overheat the
outside in order to get the right heat to the inside and allow for the
solder to flow.


  #3   Report Post  
Posted to alt.home.repair,alt.building.construction
DAC DAC is offline
external usenet poster
 
Posts: 112
Default do sloppy copper joints fail easier?

Time will tell...you could grab ahold of the pipe and move it back and
forth to see if it leaks.

A couple of tricks for the future...in the plumbing supply stores,
they may have little balls that you push into the pipe while
soldering. When done, the water will dissolve the ball. Or, you could
put a small plug of bread in pipe, solder and when the water is on
open the tap and the plug will be dissolved and flushed out.

I've heard that MAPP gas torches work well.




On Feb 27, 8:54 pm, "Edwin Pawlowski" wrote:
wrote in message

Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? or is it that if it holds water,
it is fine and will last as long as a nice looking joint. I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.


Yes, it is possible. If you got a good bond of solder inside the joint, it
will last forever. The crappy look may be just on the outside. Keep an eye
on it though. If you have to do it over, use a hotter torch rather than
play on the joint with a little propane job. You sometimes overheat the
outside in order to get the right heat to the inside and allow for the
solder to flow.



  #4   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 6,199
Default do sloppy copper joints fail easier?

On Feb 27, 10:06�pm, "DAC" wrote:
Time will tell...you could grab ahold of the pipe and move it back and
forth to see if it leaks.

A couple of tricks for the future...in the plumbing supply stores,
they may have little balls that you push into the pipe while
soldering. When done, the water will dissolve the ball. *Or, you could
put a small plug of bread in pipe, solder and when the water is on
open the tap and the plug will be dissolved and flushed out.

I've heard that MAPP gas torches work well.

On Feb 27, 8:54 pm, "Edwin Pawlowski" wrote:



wrote in message


Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. *My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? *or is it that if it holds water,
it is fine and will last as long as a nice looking joint. *I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.


Yes, it is possible. *If you got a good bond of solder inside the joint, it
will last forever. *The crappy look may be just on the outside. *Keep an eye
on it though. *If you have to do it over, use a hotter torch rather than
play on the joint with a little propane job. *You sometimes overheat the
outside in order to get the right heat to the inside and allow for the
solder to flow.- Hide quoted text -


- Show quoted text -


Use Mapp gas next time if the joints fail. Mapp is hotter and really
need with the no lead solder.

Keep a eye but most likely joints will be fine

  #5   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 879
Default do sloppy copper joints fail easier?

I had one of these fail on me. I had worked late and the inspector was due
in the next day. I arrived 5 minutes before the inspector and there was
water everywhere.

My recommendation is to leave the wall open for a few days and whack the
area with a mallet each day several times. If it survives this, you
probably have made a good joint and ugly on the outside doesn't count.


--
Roger Shoaf
If you are not part of the solution, you are not dissolved in the solvent.

wrote in message
oups.com...
I had to relocate some plumbing copper pipes in by basement. They are
3/4 pipes. They were in a difficult place and there was some moisture
in the line. I cleaned the joints well and used the flux paste like
normal, but since there was moisture in the line (dripping water in
the line) the joints took a long time to heat up. I got the solder
flowing into them eventually and I used a good amount, but they look
like crap and are burnt looking too. On some of them I can see the
solder looks like it has gaps in it at the seam.

Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? or is it that if it holds water,
it is fine and will last as long as a nice looking joint. I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.

Thanks.





  #6   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 67
Default do sloppy copper joints fail easier?

On Feb 27, 10:45 pm, "Roger Shoaf" wrote:
I had one of these fail on me. I had worked late and the inspector was due
in the next day. I arrived 5 minutes before the inspector and there was
water everywhere.

My recommendation is to leave the wall open for a few days and whack the
area with a mallet each day several times. If it survives this, you
probably have made a good joint and ugly on the outside doesn't count.

--
Roger Shoaf
If you are not part of the solution, you are not dissolved in the solvent.



Thanks, I think I will do that. I did use mapp gas on these as I
thought the hotter torch would heat it faster since it was in an
awkward place. I hope these hold!


  #7   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 82
Default do sloppy copper joints fail easier?

Finding the keyboard operational
DAC entered:

Time will tell...you could grab ahold of the pipe and move it back and
forth to see if it leaks.

A couple of tricks for the future...in the plumbing supply stores,
they may have little balls that you push into the pipe while
soldering. When done, the water will dissolve the ball. Or, you could
put a small plug of bread in pipe, solder and when the water is on
open the tap and the plug will be dissolved and flushed out.

I once saw a guy try the bread trick on a large water pipe (2 or 3 ") using
a dinner roll from the company cafeteria. He had to re open the pipe when
the roll didn't dissolve. I never ate in the cafeteria after that.
Bob
--
--
Coffee worth staying up for - NY Times
www.moondoggiecoffee.com

  #8   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 425
Default do sloppy copper joints fail easier?

I had to diagnose a pinhole leak recently. Thought it might be
condensation. It was truly a pinhole sized leak. Under full pressure it
would take 24 hrs to build up one med. sized drop. Over a week it could do
in a whole Kleenex. Over time everything would be wet. I tried using Oatey
plumbing epoxy (mixable round putty in a clear plastic tube), but it failed.
As did Devcon plastic Steel ( 2 parts in squeeze tubes). And magic wrap
rubber tape. All that is flexible stretchable rubber tape - doesn't even
bond to itself. It all leaks. I was told to do it right the first time.
Now I have to take off ceiling panel wall angle, the whole painted drywall
wall, cut through top stud (done) and do it right with soldering. The
failure of the repair may be partially blamed on the fact that I didn't turn
off the pressure at all. I have a reason for that. I can't remember using
Devcon Plastic Steel. I have used JB Kwik. Its a JB Weld product. Its
also 2 parts in squeeze tubes. But it dries fast (like in 5 minutes like
steel). Devcon Plastic Steel takes 2 hours to dry. This may have been the
reason for the failure. That and an impossible to turn broken, ridiculously
positioned water shut-off valve. If I had it to do it again (only in this
specific situation - now I am a real believer in doing it right in most
circumstances), I'd again use a type of "plastic steel" - ONLY "JB Quik",
available in the automotive dept. I'd shut off the water. Literally 5
minutes or less and it goes from peanut butter to a polished little piece of
jade. I have used JB Weld's JB Quik on a cracked engine block with
success for weeks! To close a gapping hole in a cracked engine block from
spilling pressurized coolant at (outside) engine block temp. Oh ya, and,
don't use Kleenex. Cut little strips of tissue paper, and stick them on the
joint with tiny pieces of scotch tape. Easier to see a little water than
Kleenex - it goes transparent.

wrote in message
oups.com...
I had to relocate some plumbing copper pipes in by basement. They are
3/4 pipes. They were in a difficult place and there was some moisture
in the line. I cleaned the joints well and used the flux paste like
normal, but since there was moisture in the line (dripping water in
the line) the joints took a long time to heat up. I got the solder
flowing into them eventually and I used a good amount, but they look
like crap and are burnt looking too. On some of them I can see the
solder looks like it has gaps in it at the seam.

Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? or is it that if it holds water,
it is fine and will last as long as a nice looking joint. I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.

Thanks.





----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----
  #9   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 425
Default do sloppy copper joints fail easier?

Punch the product button at
http://jbweld.net/index.php

I am not telling you not to do a real repair, or to repair at all. In my
situation there was the size of the leak, why it leaked, the tightest of
spots, with so much to do otherwise, oh, and the water didn't shut off
completely at the time. JB Weld is what it claims. I can only assume it
would work, but not sure, and don't know duration. Plumbers who say no,
probably don't know it - only KWIK. It is to steel what glue and sawdust is
to wood.


"bent" wrote in message
...
I had to diagnose a pinhole leak recently. Thought it might be
condensation. It was truly a pinhole sized leak. Under full pressure it
would





----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet
News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+
Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption
=----




----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----
  #10   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 425
Default do sloppy copper joints fail easier?

As I was just told, there is also compression type fittings. I just got a
new ball valve water shut-off with compression type fittings from HD. Inner
bore, outer thread, sleeve, nut w/ edge. Do not know if these are Kosher.


"bent" wrote in message
...
Punch the product button at
http://jbweld.net/index.php

I am not telling you not to do a real repair, or to repair at all. In my




----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----


  #11   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 5,823
Default do sloppy copper joints fail easier?


"bent" wrote in message
...
As I was just told, there is also compression type fittings. I just got a
new ball valve water shut-off with compression type fittings from HD.
Inner bore, outer thread, sleeve, nut w/ edge. Do not know if these are
Kosher.


Compression fittings are not to be used in a concealed location, such as in
a wall. They have a place, but for regular plumbing repairs, they are for
sissies afraid to learn to make a good sweat joint.


  #12   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 425
Default do sloppy copper joints fail easier?

it is not in a wall: please fix me:

My original main water shut-off valve is leaking about 12oz./minute. I
purchased a B&K 3/4" Ball Valve with compression fittings which I want to
install in a vertical stretch of 3/4" copper tubing JUST AFTER the
horizontally mounted Trident Canada/Neptune water meter.

In order to fit the new valve into the " vertical tube run I have bought a
wheel-type mini tube cutter. The installed valve will be about 3-7/8" from
end to end. I have measured both sides for the distances from the outer edge
to the bottoming point (1.404" & 1.272"), and subtracting from the 3-7/8",
the valve will displace approximately 1.282" of 3/4" vertical copper tubing,
which I have to cut out, after I wash but not sand the outside. This method
requires me to disconnect the pipe/tube with elbow at the water meter thread
boss "out"-end connection with the nut.

The other method of installing the valve is not to disconnect the pipe/tube
at the water meter "out"-end and to cut the gap larger than the calculated
1.282", so I can slip the nuts then sleeves on both end pieces of cut Vert.
tubing, and slide on one end of the valve up to the bottoming point, then
align and slip on the other end of the valve, and center it all for equal
but not bottoming connection on each side. I am not sure how much to cut out
in this case w/r/t engagement lengths.

Are the sleeves tight, should I pre-heat them in boiling water to expand
them, and make a wooden sliding tool.

To take the pressure off me, I may be able to stop the flow instead of using
just buckets/trays rags while Liters flow. I bought a 3/4" galvanized cap in
the plumbing dept of HD which seems to have the same thread as the thread on
the "out"-end connection of the water meter. I am out of my depth w/r/t the
thread types, like NPT vs. NC, but on the meter I viewed 4 threads (5
crests) in 4-1/2 or 4-2/3 sixteenths on a steel rule and a major diameter of
1.044" using a dial caliper, which is an estimated 1"-14, regardless of
thread type. The cap I got has a similar visual distance between 5 crests
(4-1/2+), and a minor diameter of .934". That's a .110" (1.76/16ths) diff
b/t meter's max thread and nut's min thread diameters, and a visual equality
of tpi,+/- 0.1/16". Still I am in no way sure if this cap thread is designed
to fit the thread on the water housings boss, or even if I SHOULD disconnect
the water meter "out"-end connection in the first place, since it may not
re-seal correctly or require seals . Also, the HD guy said to use Teflon
tape to seal the cap, but what about re-assembly and whether to clean or add
Teflon tape, with or w/o seals or fittings. There are no visible signs of
tape or dope now on either side of the water meter.

QUESTIONS:

1)How to finish the old 3/4" copper tube cut ends I'll be putting into the
valve bores after using the tube cutter. I am not sure about inside burrs
breaking away and floating into fittings downstream.

2)Which of my two valve assembly methods to use for sliding the valves'
bores onto the tubes' cut ends, and what about ease of sleeve manipulation

3)Will I disconnect/re-connect at the water meters "out" connection and if
there are any seals or fittings of any material I need to obtain, and if I
can (safely) use a galvanized cap temporarily to stop the leaking water
flow, with or without Teflon tape or plumbers dope

4)Is a compression fitting Kosher, especially since its a shut-off valve? I
have it because there will be water flowing through if I don't disconnect at
the water meter "out"-end connection, and I am a diy'er and not sure of my
Vertical soldering anyway



----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----
  #13   Report Post  
Posted to alt.home.repair,alt.building.construction
external usenet poster
 
Posts: 37
Default do sloppy copper joints fail easier?

It's probably OK. If the joint is over the ground under a raised
foundation, check for a wet spot in the dirt when you get around to
it, but again, it sounds like you're OK. I've had the same problem
several times even using Mapp gas, heat was hard to steam away excess
water, in a situation under the house where I'm tried to
simultaneously hold a piece of drywall as a fire break against burning
floor joists, as I also hold the solder and torch. But, eventually,
the joints soldered. I've had all these for several years now,
admittably much to my own amazement.

About the bread idea--not really so good. I've tried this too, and had
crap back up into my faucet screens. Some screens, like the weird
little plastic ones in my expensive Grohe masterbath faucets are a
real hassle to clean. So, if you use the bread, take off all the
fawcett screens and flush completely before considering your work
done. If the dissolve pills work, that's great, but normally, I don't
keep things like that in stock, so I just want to get the job done.
It's best to simply isolate the area with shut-off valves, pull the
pipe down to drain to completely, and then if necessary prop the pipe
either up or down to keep the excess water away during soldering.
I've learned to very careful when determining in which order to solder
joints. If I can bench solder everything but that last pain the butt
joint, then at least I know I've only got one joint to keep an eye on
later.


On Feb 27, 6:46 pm, wrote:
I had to relocate some plumbing copper pipes in by basement. They are
3/4 pipes. They were in a difficult place and there was some moisture
in the line. I cleaned the joints well and used the flux paste like
normal, but since there was moisture in the line (dripping water in
the line) the joints took a long time to heat up. I got the solder
flowing into them eventually and I used a good amount, but they look
like crap and are burnt looking too. On some of them I can see the
solder looks like it has gaps in it at the seam.

Anyway, they aren't leaking and I tried to shake them/stress the joint
and they still hold fine. My question is this, it is possible that I
burned off the flux while heating it so long...does this mean that
these joints can fail prematurely? or is it that if it holds water,
it is fine and will last as long as a nice looking joint. I have read
that pinholes can happen when the joint is soldered, but not sure
about after the fact.

Thanks.



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Faster, easier box joints on the TS boorite Woodworking 0 September 14th 06 06:56 PM
solderless vs soldered copper joints. Frank Home Repair 8 August 22nd 06 05:47 PM
Traditional M&T joints or floating Tennon joints? mcgyver Woodworking 12 August 13th 06 02:40 PM
easier dig 2m foundations [email protected] UK diy 6 November 29th 05 10:56 PM
HELP: Soldering joints for my copper fireplace hood...................................See URL for pic john Metalworking 23 February 23rd 05 10:09 PM


All times are GMT +1. The time now is 10:52 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright 2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"