Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 19
Default Zoeller M-53 (1/3 HP) Sump Pump Not Switching Off

My Zoeller M-53 (1/3 HP) sump pump does not switch off. I.e., the sump
pump kicks on fine when the float gets to the level that causes the
pump to kick on. It begins to pump water out like normal but then when
it gets to a certain point, it stops pumping water out. The pump keeps
running but the water level doesn't recede any further. I have to push
the float down a little bit in order for it to stop running.

Any ideas what I could do to fix this problem? Is the switch going
bad?

Thanks,
Kevin

  #2   Report Post  
Posted to alt.home.repair
RBM RBM is offline
external usenet poster
 
Posts: 1,690
Default Zoeller M-53 (1/3 HP) Sump Pump Not Switching Off

It sounds like the float is stuck. If the float moves freely up and down,
completely and it doesn't shut off, you probably need a new switch


"Kevin G." wrote in message
ups.com...
My Zoeller M-53 (1/3 HP) sump pump does not switch off. I.e., the sump
pump kicks on fine when the float gets to the level that causes the
pump to kick on. It begins to pump water out like normal but then when
it gets to a certain point, it stops pumping water out. The pump keeps
running but the water level doesn't recede any further. I have to push
the float down a little bit in order for it to stop running.

Any ideas what I could do to fix this problem? Is the switch going
bad?

Thanks,
Kevin



  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 19
Default Zoeller M-53 (1/3 HP) Sump Pump Not Switching Off

Thanks for your reply.

Are switches easy to replace? If so, would you be able to tell me
step-by-step how to do it (or refer me to a website that might have
information)?

Thanks in advance,
Kevin


RBM (remove this) wrote:
It sounds like the float is stuck. If the float moves freely up and down,
completely and it doesn't shut off, you probably need a new switch


"Kevin G." wrote in message
ups.com...
My Zoeller M-53 (1/3 HP) sump pump does not switch off. I.e., the sump
pump kicks on fine when the float gets to the level that causes the
pump to kick on. It begins to pump water out like normal but then when
it gets to a certain point, it stops pumping water out. The pump keeps
running but the water level doesn't recede any further. I have to push
the float down a little bit in order for it to stop running.

Any ideas what I could do to fix this problem? Is the switch going
bad?

Thanks,
Kevin


  #4   Report Post  
Posted to alt.home.repair
RBM RBM is offline
external usenet poster
 
Posts: 1,690
Default Zoeller M-53 (1/3 HP) Sump Pump Not Switching Off

I believe that is just a lever activated switch. It would have two wires
connected to it and would be inside a water tight enclosure. I'm sure, once
you figure out how to expose it, the replacement will be easy. You can try
Zoeller's website for any breakdowns on the pump
"Kevin G." wrote in message
ups.com...
Thanks for your reply.

Are switches easy to replace? If so, would you be able to tell me
step-by-step how to do it (or refer me to a website that might have
information)?

Thanks in advance,
Kevin


RBM (remove this) wrote:
It sounds like the float is stuck. If the float moves freely up and down,
completely and it doesn't shut off, you probably need a new switch


"Kevin G." wrote in message
ups.com...
My Zoeller M-53 (1/3 HP) sump pump does not switch off. I.e., the sump
pump kicks on fine when the float gets to the level that causes the
pump to kick on. It begins to pump water out like normal but then when
it gets to a certain point, it stops pumping water out. The pump keeps
running but the water level doesn't recede any further. I have to push
the float down a little bit in order for it to stop running.

Any ideas what I could do to fix this problem? Is the switch going
bad?

Thanks,
Kevin




  #5   Report Post  
Posted to alt.home.repair
RBM RBM is offline
external usenet poster
 
Posts: 1,690
Default Zoeller M-53 (1/3 HP) Sump Pump Not Switching Off

Here is a link to the parts breakdown for your pump:
http://www.zoeller.com/zcopump/zcopdfdocs/FM0472.pdf



"RBM" rbm2(remove wrote in message
...
I believe that is just a lever activated switch. It would have two wires
connected to it and would be inside a water tight enclosure. I'm sure, once
you figure out how to expose it, the replacement will be easy. You can try
Zoeller's website for any breakdowns on the pump
"Kevin G." wrote in message
ups.com...
Thanks for your reply.

Are switches easy to replace? If so, would you be able to tell me
step-by-step how to do it (or refer me to a website that might have
information)?

Thanks in advance,
Kevin


RBM (remove this) wrote:
It sounds like the float is stuck. If the float moves freely up and
down,
completely and it doesn't shut off, you probably need a new switch


"Kevin G." wrote in message
ups.com...
My Zoeller M-53 (1/3 HP) sump pump does not switch off. I.e., the
sump
pump kicks on fine when the float gets to the level that causes the
pump to kick on. It begins to pump water out like normal but then
when
it gets to a certain point, it stops pumping water out. The pump
keeps
running but the water level doesn't recede any further. I have to
push
the float down a little bit in order for it to stop running.

Any ideas what I could do to fix this problem? Is the switch going
bad?

Thanks,
Kevin








  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 408
Default Zoeller M-53 (1/3 HP) Sump Pump Not Switching Off



Are switches easy to replace? If so, would you be able to tell me
step-by-step how to do it (or refer me to a website that might have
information)?


before replacing the switch, check that the float travel may just need
to be adjusted

Mark

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Goulds Irrigation pump Not Working HELP [email protected] Home Repair 1 May 31st 06 09:47 PM
Sump Pump 538$ m Ransley Home Repair 8 March 27th 06 07:29 PM
Questions - Battery Back-up Sump Pump Keith Home Repair 20 January 28th 06 11:43 PM
sump pump lifetime? peter Home Repair 8 January 3rd 06 09:14 AM
Sump Pump Help Needed [email protected] Home Repair 14 April 25th 05 05:09 PM


All times are GMT +1. The time now is 10:38 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us