My first time constructing a Recroom. I guess I can't get everything right
the first time.

Anyway, I got the wiring done and proceded onto the Vapor Barrier and
Gyproc. Got halfway done the walls with Gyproc and realized I forgot to
pull the wire for the heater though the vapor Barrier and gyproc!! I really
don't want to ruin a sheet of gyproc to get it out.

What are my options? I kinda remember where it is, it's either in one 16"
length or the one next to it. Can I use that current detector to find it
through the gyproc then cut a small hole to pull it out? I don't have one
buy I could get a loan of my friends.

Any suggestions.

Thanks,

--
Steve


  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,586
Default Made a mistake

SteveC wrote:
My first time constructing a Recroom. I guess I can't get everything right
the first time.

Anyway, I got the wiring done and proceded onto the Vapor Barrier and
Gyproc. Got halfway done the walls with Gyproc and realized I forgot to
pull the wire for the heater though the vapor Barrier and gyproc!! I really
don't want to ruin a sheet of gyproc to get it out.

What are my options? I kinda remember where it is, it's either in one 16"
length or the one next to it. Can I use that current detector to find it
through the gyproc then cut a small hole to pull it out? I don't have one
buy I could get a loan of my friends.

Any suggestions.

Thanks,

Hi,
How can you detect current if the wire is not alive yet?
  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 12
Default Made a mistake


Tony Hwang wrote:
snip
Hi,
How can you detect current if the wire is not alive yet?

Simple. The data cablers do it all the time with a tone
generator and listener.
http://www.lanshack.com/CableTracker...Q9m 5TfQpSHCy

....thehick

  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 3,044
Default Made a mistake


SteveC wrote:
My first time constructing a Recroom. I guess I can't get everything right
the first time.

Anyway, I got the wiring done and proceded onto the Vapor Barrier and
Gyproc. Got halfway done the walls with Gyproc and realized I forgot to
pull the wire for the heater though the vapor Barrier and gyproc!! I really
don't want to ruin a sheet of gyproc to get it out.

What are my options? I kinda remember where it is, it's either in one 16"
length or the one next to it. Can I use that current detector to find it
through the gyproc then cut a small hole to pull it out? I don't have one
buy I could get a loan of my friends.

Any suggestions.

Thanks,

--
Steve


Waste the 'rock. You are talking about less than $10 (been a long
while since I bought any). It doesn't even have to be the full sheet.
Or just cut a good sized hole where you need it. Patching a big hole
isn't much more work than patching a small one.

Harry K

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 4,764
Default Made a mistake

Harry K wrote:

Waste the 'rock. You are talking about less than $10 (been a long
while since I bought any). It doesn't even have to be the full sheet.
Or just cut a good sized hole where you need it. Patching a big hole
isn't much more work than patching a small one.


Along those lines...if you use a keyhole saw and angled the handle
outwards, away from the hole, as you cut, the resulting piece will form
a plug for the hole. In other words you can smear some joint compound
on the edges put the cutout piece back in place and tape the edges. No
blocking or additional cutting needed and it doesn't matter what shape
you cut out.

R



  #6   Report Post  
Posted to alt.home.repair
EXT EXT is offline
external usenet poster
 
Posts: 1,661
Default Made a mistake

Been there, done that. If you installed your drywall with screws, just back
them out, drop the panel, find your cable and cut an opening for it. This is
one of the reasons you should always use screws. If you went and used nails,
well I have taken nails out as well. You need a nail puller to get under the
nail head, then pry the nail out by sliding a putty knife blade behind the
nail puller to avoid crushing the drywall. Once loosened you can use a claw
hammer to finish extracting the nail. This does more damage to the sheet
than screws, but it can all be fixed with mud. Don't bother putting
replacement nails or screws in the same holes, put them in new locations.

"SteveC" wrote in message
...
My first time constructing a Recroom. I guess I can't get everything
right the first time.

Anyway, I got the wiring done and proceded onto the Vapor Barrier and
Gyproc. Got halfway done the walls with Gyproc and realized I forgot to
pull the wire for the heater though the vapor Barrier and gyproc!! I
really don't want to ruin a sheet of gyproc to get it out.

What are my options? I kinda remember where it is, it's either in one 16"
length or the one next to it. Can I use that current detector to find it
through the gyproc then cut a small hole to pull it out? I don't have one
buy I could get a loan of my friends.

Any suggestions.

Thanks,

--
Steve



  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,586
Default Made a mistake

thehick wrote:

Tony Hwang wrote:
snip

Hi,
How can you detect current if the wire is not alive yet?


Simple. The data cablers do it all the time with a tone
generator and listener.
http://www.lanshack.com/CableTracker...Q9m 5TfQpSHCy

...thehick

Hi,
Of course. I have a tone generator.
  #8   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 22
Default Made a mistake

Thanks for all your help, I just cut a rectangle around where I thought it
was, got it the second time around!! LOL

Then I just made the hole and then screwed it back in. Then when I get it
plastered, it can be fixed no problem.

Thanks all.

--
Steve
"EXT" wrote in message
anews.com...
Been there, done that. If you installed your drywall with screws, just
back them out, drop the panel, find your cable and cut an opening for it.
This is one of the reasons you should always use screws. If you went and
used nails, well I have taken nails out as well. You need a nail puller to
get under the nail head, then pry the nail out by sliding a putty knife
blade behind the nail puller to avoid crushing the drywall. Once loosened
you can use a claw hammer to finish extracting the nail. This does more
damage to the sheet than screws, but it can all be fixed with mud. Don't
bother putting replacement nails or screws in the same holes, put them in
new locations.

"SteveC" wrote in message
...
My first time constructing a Recroom. I guess I can't get everything
right the first time.

Anyway, I got the wiring done and proceded onto the Vapor Barrier and
Gyproc. Got halfway done the walls with Gyproc and realized I forgot to
pull the wire for the heater though the vapor Barrier and gyproc!! I
really don't want to ruin a sheet of gyproc to get it out.

What are my options? I kinda remember where it is, it's either in one
16" length or the one next to it. Can I use that current detector to
find it through the gyproc then cut a small hole to pull it out? I don't
have one buy I could get a loan of my friends.

Any suggestions.

Thanks,

--
Steve





Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Big mistake with Stain and Wood Conditioner/Seal a cell Keith Woodworking 4 August 27th 06 05:06 AM
Fence Post Replacement -- I may have already made a mistake.. advice sought...... Jim McLaughlin Home Repair 2 August 12th 06 06:54 PM
repost - teahing kids woodworking - great story charlie b Woodworking 4 March 21st 06 02:08 AM
Metal Working Machinery New and Used in Australia and for Export [email protected] Metalworking 0 February 23rd 05 02:54 AM
Making a ruin into something habitable. Liz UK diy 140 August 12th 03 12:03 PM


All times are GMT +1. The time now is 05:04 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"