Home Repair (alt.home.repair) For all homeowners and DIYers with many experienced tradesmen. Solve your toughest home fix-it problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 16
Default Shielding Electrical Ignition Noise from Oil Burner


My heating system uses a Carlin 101 burner head with constant
ignition spark.

Should there be a direct wire connection from the burner head chassis
to an earth ground?

I would think that the chassis being metalic would shield the spark
ignition noise, but the running burner causes a high level noise in HF
receiver.

Thanks.
  #2   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 48
Default Shielding Electrical Ignition Noise from Oil Burner


Vince wrote:
My heating system uses a Carlin 101 burner head with constant
ignition spark.

Should there be a direct wire connection from the burner head chassis
to an earth ground?

I would think that the chassis being metalic would shield the spark
ignition noise, but the running burner causes a high level noise in HF
receiver.

Thanks.


I dont know why you couldnt...Any mettallic object in your furnace
should be grounded anyway for safety.....an additional ground to earth
surely wont hurt anything...worth a try.

Wonder if you could use one of those noise filters on the furnace power
supply but wired in reverse in order to keep the trash from getting out
of the furnace into the mains...

Ive seen this done with high frequency spark equipment before.....

How bout a filter on the power supply to your receiver ???

  #3   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 408
Default Shielding Electrical Ignition Noise from Oil Burner


My heating system uses a Carlin 101 burner head with constant
ignition spark.

Should there be a direct wire connection from the burner head chassis
to an earth ground?

I would think that the chassis being metalic would shield the spark
ignition noise, but the running burner causes a high level noise in HF
receiver.

Thanks.




My furnace uses constant spark also but I don't have any EMI from it.
The transfomer and all the secondary wires and the spark gap are all
shielded inside the metal combustion chamber. It doesn't reall ymatter
if it ig grounded or not as long as it is enclosed in metal... you
might try a resistor in series of the type made for autombile
ignitions...

be VERY carfeul with the transformer secondary side, that voltage can
easily kill you...

Mark

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Overhead electrical service to a storage shed Timothy J. Trace Home Repair 3 December 3rd 03 04:21 AM
New Electrical Regs PoP UK diy 22 September 1st 03 08:41 PM
Installing Electrical Outlet In Sink Cabinet Matty Home Repair 0 August 27th 03 03:08 PM
Microwave interferes with AM radio TOM KAN PA Home Repair 8 August 4th 03 12:31 AM
Forthcoming Building Regulations on electrical work (Part P) Andrew McKay UK diy 42 July 30th 03 08:05 AM


All times are GMT +1. The time now is 10:40 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"