First thanks for all you do, frequently in the worst weather and
conditions. I am certain everyone appreciates getting their service
restored. Sadly around pittsburgh Duquesne light tends to wait till a
overloaded tranmsformer fries before replacing it. Even one thats
tripped it thermal protection repeatedly

Anyhow my question. Before working on what you BELIEVE is a dead line
do you short it just to be on the safe side?

I was told this by a local lineman and just want to confirm. thanks bob
haller...

if you do short lines do you occasionally find one thats still
live???????

  #3   Report Post  
Posted to alt.home.repair
Bob Bob is offline
external usenet poster
 
Posts: 11
Default Question just for electrical linemen!


wrote in message
oups.com...
First thanks for all you do, frequently in the worst weather and
conditions. I am certain everyone appreciates getting their service
restored. Sadly around pittsburgh Duquesne light tends to wait till a
overloaded tranmsformer fries before replacing it. Even one thats
tripped it thermal protection repeatedly

Anyhow my question. Before working on what you BELIEVE is a dead line
do you short it just to be on the safe side?


Depending on voltage and proximity either a meter, or tick tracer is used to
verify lines and equipment is non-energized prior to safety grounds being
applied.
Safety grounds are not really effective on the secondary side of a low
voltage transformer. At 13,200 volts, there's only a few thousand amps
available. Not nearly enough current to do anything spectacular with the
safety ground (usually 4/0, fine strand) for the short duration that the
current will be available, assuming good contact with the conductors. On the
secondary side of your typical pad mount 200 kva transformer, normal current
phase to ground on the secondary is on the order of 1600 amps continuous.
Available shourt circuit current might be 20,000 amps or more for a while.
Long enough to burn up a safety ground.

Short answer... grounds are not applied until lines are verified dead.


I was told this by a local lineman and just want to confirm. thanks bob
haller...

if you do short lines do you occasionally find one thats still
live???????


Grounds are occasionally accidentally applied to hot lines. It shouldn't
happen if proper procedures are followed.


  #4   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 6,199
Default Question just for electrical linemen!

theres was a event here a few years ago.

someone made a bad switch throw, a worker walking by a safety ground
got tossed off the tower when the safety ground exploded.

worker got lifeflighted to hospital trauma unit

  #5   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 311
Default Question just for electrical linemen!

I'm not a lineman, so I should not answer.
But, if I were dealing with the high voltage before a pole
transformer, I sure as heck would not short it to test.
Thats what test instruments are for. One other thing. There is always
a removable fuse before a transformer, and I have always seen linemen
remove it before working on a transformer. Now if they are working on
the HV wires themselves, there is more of a risk.

Mark

--------------------

On 1 Aug 2006 18:42:18 -0700, "
wrote:

First thanks for all you do, frequently in the worst weather and
conditions. I am certain everyone appreciates getting their service
restored. Sadly around pittsburgh Duquesne light tends to wait till a
overloaded tranmsformer fries before replacing it. Even one thats
tripped it thermal protection repeatedly

Anyhow my question. Before working on what you BELIEVE is a dead line
do you short it just to be on the safe side?

I was told this by a local lineman and just want to confirm. thanks bob
haller...

if you do short lines do you occasionally find one thats still
live???????




  #6   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 818
Default Question just for electrical linemen!

Not a lineman.

However, I've also heard that the line guys will short a line to
ground while working on it -- even if it's supposedly disconnected.
I've also heard that if a home owner is found to be back feeding to
the grid, they will disconnect the person from the grid, and it takes
many months to get the guy hooked back up.

--

Christopher A. Young
You can't shout down a troll.
You have to starve them.
..

wrote in message
oups.com...
First thanks for all you do, frequently in the worst weather and
conditions. I am certain everyone appreciates getting their service
restored. Sadly around pittsburgh Duquesne light tends to wait till a
overloaded tranmsformer fries before replacing it. Even one thats
tripped it thermal protection repeatedly

Anyhow my question. Before working on what you BELIEVE is a dead line
do you short it just to be on the safe side?

I was told this by a local lineman and just want to confirm. thanks
bob
haller...

if you do short lines do you occasionally find one thats still
live???????


  #7   Report Post  
Posted to alt.home.repair
external usenet poster
 
Posts: 66
Default Question just for electrical linemen!

Stormin Mormon" wrote in message
...
Not a lineman.

However, I've also heard that the line guys will short a line to
ground while working on it -- even if it's supposedly disconnected.
I've also heard that if a home owner is found to be back feeding to
the grid, they will disconnect the person from the grid, and it takes
many months to get the guy hooked back up.

Yep. Lineman have been killed due to backfeeding from generaters. Use a
transfer switch!

Here are some videos of power distribution tests and accidents. Check out
the quarter shrinker too!
http://205.243.100.155/frames/longarc.htm
John


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Good morning or good evening depending upon your location. I want to ask you the most important question of your life. Your joy or sorrow for all eternity depends upon your answer. The question is: Are you saved? It is not a question of how good mac davis Woodworking 0 April 21st 05 05:38 PM
To anyone sick of alt.hvac Matt Morgan Home Repair 87 April 8th 05 05:17 PM
OT Guns more Guns Cliff Metalworking 519 December 12th 04 05:52 AM
Plumbing Question Jeff UK diy 4 December 1st 03 01:49 PM
Question????? Sir Edgar Woodworking 8 July 20th 03 05:22 PM


All times are GMT +1. The time now is 06:20 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"