venting bath exhaust fan through 2x4 studs
I have a "ventless" bath exhaust fan I would like to replace. It is a
wall unit and there are several vertical studs in the 8' distance to the outside wall. This would make it impossible to run the 3" horizontal venting tube. Is there any way to solve this problem. Should I install one in the sealing and cover up the 7x9 cutout in the wall?? Any advice appreciated Vic |
#2
Posted to alt.home.repair
|
|||
|
|||
venting bath exhaust fan through 2x4 studs
Exhaust fans with three inch duct are pretty worthless anyway. Either get a
decent ceiling mounted unit or a remote mounted unit "vic" wrote in message oups.com... I have a "ventless" bath exhaust fan I would like to replace. It is a wall unit and there are several vertical studs in the 8' distance to the outside wall. This would make it impossible to run the 3" horizontal venting tube. Is there any way to solve this problem. Should I install one in the sealing and cover up the 7x9 cutout in the wall?? Any advice appreciated Vic |
#3
Posted to alt.home.repair
|
|||
|
|||
venting bath exhaust fan through 2x4 studs
"RBM" rbm2(remove wrote in message ... Exhaust fans with three inch duct are pretty worthless anyway. Either get a decent ceiling mounted unit or a remote mounted unit "vic" wrote in message oups.com... I have a "ventless" bath exhaust fan I would like to replace. It is a wall unit and there are several vertical studs in the 8' distance to the outside wall. This would make it impossible to run the 3" horizontal venting tube. Is there any way to solve this problem. Should I install one in the sealing and cover up the 7x9 cutout in the wall?? Any advice appreciated Vic I used a ceiling fan with 3" outlet. Mounted vertical in wall, exhaust comes out the top, fashioned a 3" PVC elbow and then directly through the wall with a dryer vent cover on the outside. Sealed up the joints with some super strength epoxy. Took a bit of sawing, filing and grinding on the pipe but it was worth the work. As the saying goes, necessity is a mother...or something like that. Bob |
#4
Posted to alt.home.repair
|
|||
|
|||
venting bath exhaust fan through 2x4 studs
The problem with 3" vents is that there are non that move more than around
70 CFM and non that are made well. If you got to 4", the sky's the limit "RobertM" wrote in message ... "RBM" rbm2(remove wrote in message ... Exhaust fans with three inch duct are pretty worthless anyway. Either get a decent ceiling mounted unit or a remote mounted unit "vic" wrote in message oups.com... I have a "ventless" bath exhaust fan I would like to replace. It is a wall unit and there are several vertical studs in the 8' distance to the outside wall. This would make it impossible to run the 3" horizontal venting tube. Is there any way to solve this problem. Should I install one in the sealing and cover up the 7x9 cutout in the wall?? Any advice appreciated Vic I used a ceiling fan with 3" outlet. Mounted vertical in wall, exhaust comes out the top, fashioned a 3" PVC elbow and then directly through the wall with a dryer vent cover on the outside. Sealed up the joints with some super strength epoxy. Took a bit of sawing, filing and grinding on the pipe but it was worth the work. As the saying goes, necessity is a mother...or something like that. Bob |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
venting bath fan to outside from attic... | Home Ownership | |||
Venting bath exhaust fan | Home Repair | |||
Bath exhaust fan | Home Repair | |||
Dryer Exhaust Venting Tip | Home Repair | |||
Bathroom exhaust fans venting in attic. Problem? | Home Repair |