goodman a/c not cooling
Hey, I have an all goodman system, Gmnt100-4 furnace, u-49 coil, and a
clt48-1a compressor. This replace a heil heat only system. Heat works great but the a/c doesn't. I't will not cool down the house. 2 techs said the charge was good. 1 tech didn't know what was wrong, the other says the u49 coil is too small for the clt48 (13seer) compressor. He said even though there both 4 ton, the u49 was made for a 10seer compressor. He want to replace the coil w/ a 5 ton. Are they not compadible? Is this the right thing to do? I was wondering if the duct work in the house was too small and I'd be better off with a 3.5 ton compressor w/ the 4ton coil. Any Ideas? Running the a/c w/ the cover off the furnace doesn't help, I guess that means it has enough returned air. It doesn't freeze up. Thanks |
#2
Posted to alt.home.repair
|
|||
|
|||
goodman a/c not cooling
|
#3
Posted to alt.home.repair
|
|||
|
|||
goodman a/c not cooling
|
#4
Posted to alt.home.repair
|
|||
|
|||
goodman a/c not cooling
"Travis Jordan" wrote in message . .. wrote: Hey, I have an all goodman system, Gmnt100-4 furnace, u-49 coil, and a clt48-1a compressor. This replace a heil heat only system. Heat works great but the a/c doesn't. I't will not cool down the house. Nothing wrong with that combination....44K BTU output. Certificate of ARI-Certified Performance The following Single Phase, Year-Round Air-Conditioner, Remote Air-Cooled Condensing Unit Outdoor Unit Model Number: CLT48-1* combined with Indoor Unit Model Number: ARUF049-00*-1* manufactured by: GOODMAN MANUFACTURING CO., LP. under the Trade/Brand Name: Janitrol, GMC, Franklin, Goodman, Amana, EverStar, EverRest has been rated in accordance with ARI Standard 210/240-2005 for UNITARY AIR-CONDITIONING AND AIR-SOURCE HEAT PUMP EQUIPMENT and is certified by the Air-Conditioning and Refrigeration Institute to meet the following product performance ratings: Cooling Capacity (Btuh): 44000 * Voluntarily revised, unless accompanied with a WAS in which case the change is involuntary. SEER Rating (Cooling): 13.00 ARI Reference #: 517622 Today's Date: 04 / 20 /06 Status: Active I would have matched a u-61 with that condenser for a higher seer rating. The 49 might be just enough with the variable speed blower but I would still go with the bigger coil with a 4 ton condenser. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
outside air conditioning cooling fan keeps running | Home Repair | |||
Question on cooling coils | Home Repair | |||
Goodman A/C quality ? | Home Ownership | |||
Evaporative cooler question | Home Repair | |||
condensation on ductwork and cooling efficiency | Home Repair |