OK, just bought a house. My last house I built was a walk out basement, so
the only time my sump pump even went off was when I stuck a hose in it to test. 6 years and it never filled at all. This house is a standard ranch, poured basement, with a pump that runs. My well is 24 inches deep, 17 inches wide. From the base of the well to the bottom of the single 4" feeder pipe is 12". Then the top of the pipe is 16" above the bottom of the well, and 8" from the top. Now yesterday we had one of those weird wisconsin winter thunder storms, with constant rain all day. The sump pump was going off about every 90 seconds, running for about 15 or 20 seconds each time. I thought that was way too much. So I kept it from firing off while I watched it fill at one point, and I saw that once the water got around 1/2" to 1" above the *bottom* lip of the feeder pipe, it leveled off and filled very very very slowly after that. In fact, I had it actually off for about 6 or so hours, and that was how long it took it to raise up another 5 inches or so. Once it got that high, I let the pump run again, and it ran until it got down to the point where the water level around the house was no longer above the top of the pipe, and was once again hitting equilibrium a little over the bottom lip. So here's my questions. This has a floater valve, one of the teathered units that has the switch that fires when it gets inverted beyond a certain point from the water rising. But there's not enough there for me to adjust it so it doesn't run every four or five minutes. Right now, 24 hours after the rain, it's firing off every four minutes or so. I measured things a few minutes ago, and here's what I found. The pump running takes the water down to 6". Then it shuts off. From that point, it takes the water about 30 seconds to get up to the 13" level (one inch over the bottom lip of the feeder pipe). from that point, it took longer than I wanted to stand down there waiting to see it rise even half an inch. So my questions a 1 Is there any reason that it has to run and try to keep the water *below* the lip of the feeder pipe? 2 Considering how long it was able to go without running during the rain to get the water level up to the top of the feeder pipe (which is still 8" below the lip of the well), is there anything wrong with setting it to run far less often, but just for longer? I'd rather have it fire off every four or five hours during a storm and run for 5 minutes or something than have it do the every 90 seconds running. That frequency just seems like it's begging for a burned out motor. 3 Is there any level I should not be comfortable with it rising to before it kicks off the sump pump? 4 I hear a thump a bit when the backup valve engages after the pump is done (as well as the rattling a bit of the pipe going through the floor joists without any padding there - gotta fix that). They have the valve about 5 or 6 inches *above* floor level, so when it stops, the bottom of the pipe below that valve empties back, and fills with air. So the next time the pump kicks off, there's 16 inches of air in the pipe, and you can hear the air as it bubbles through when the pump starts. Should I have that valve lower, like right off the top of the pump, so that there's no air in the pipe? Or does that one way valve have to be above the lip for some reason? 5 It rises about 10 feet before going horizontal out of the house. And with the rate of water I cited above, what should I look at for a replacement? I had an issue with the float valve being kind of "sticky" yesterday when I was testing things out, and I'm sure it's just one of the cheaper ones that builders use to maximize their profits. I'd like to replace it with something quiet. Considering the rate of flow once the bottom of the unit fills up, I'm hoping I can get away with one of the smaller HP units that I would assume are more likely to be quieter? With the description above, does anyone have any suggestions for what I could get that would be more silent than this one I have now? Thanks for any help. I'm also going to be dealing with a backup unit (one of the battery ones most likely) next spring to make sure I'm covered when spring hits, since it's not unheard of to lose power around here (southeast wisconsin). -- John |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Choosing a sump pump | Home Repair | |||
Sump Pump Help Needed | Home Repair | |||
Basement Water Despite Sump Pump | Home Repair | |||
Dehumidifier and Sump Pump | Home Repair | |||
sump pump drain pipe size | Home Repair |