Brian
 
Posts: n/a
Default Forced hot water - baseboard heat problem.


I have a small problem I need help with. I have forced hot water with baseboard heat. My expansion
tank sprung a leak last week. I replaced it by spinning the old one off and spinning the new one
on. In the process I lost some water. My problem is that now when the heat comes on I hear water
running through the baseboards. I know there's a way to bleed the zones but I have forgoten how. I
also remember it has something to do with the faucet and shut off valves at the end of each zones
run back to the furnace. One last thing, on the top of the manifold that the expansion tank
attaches to, there's a small round part with what looks like a tire valve stem on the top of it. It
has a cap on the stem and when I loosen the cap, water starts dripping out. Is this some kind of
bleeder ??? Do I leave the cap loose and let it drip ????

Thanks
Brian
  #2   Report Post  
Posted to alt.home.repair
Bob
 
Posts: n/a
Default Forced hot water - baseboard heat problem.

The easy way, is to turn the electric off, relieve the system pressure,
replace that "small round part with what looks like a tire valve stem on the
top of it" (automatic air vent), add water to the system, turn the electric
on, and wait a few days. The cap is just there to close it off if it starts
leaking. It should normally be loose. Most times, the air will eventually
work it's way around and come out that vent.



The harder, but quicker and more positive way of getting the air out, is to
first turn off the electric, then close all (return line) shut off valves
that are between the "faucet" (boiler drain valve) and the heater. Then put
a hose on one of the drains, purge the air out by opening the drain valve,
repeat the process on each zone, and then open the shut off valves. With
this method, you need to maintain constant system pressure.



"Brian" wrote in message
...

I have a small problem I need help with. I have forced hot water with

baseboard heat. My expansion
tank sprung a leak last week. I replaced it by spinning the old one off

and spinning the new one
on. In the process I lost some water. My problem is that now when the

heat comes on I hear water
running through the baseboards. I know there's a way to bleed the zones

but I have forgoten how. I
also remember it has something to do with the faucet and shut off valves

at the end of each zones
run back to the furnace. One last thing, on the top of the manifold that

the expansion tank
attaches to, there's a small round part with what looks like a tire valve

stem on the top of it. It
has a cap on the stem and when I loosen the cap, water starts dripping

out. Is this some kind of
bleeder ??? Do I leave the cap loose and let it drip ????

Thanks
Brian



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Cheap heating Russell Eberhardt UK diy 91 October 27th 05 01:30 PM
Hot product for hot water ...products compaed [email protected] Home Repair 16 January 30th 04 04:07 AM
NO MORE hot water problems [email protected] Home Repair 9 January 29th 04 06:15 PM
I need a little advice on running waterlines in an uninsulated crawlspace ozark Home Repair 12 January 29th 04 05:23 AM
Flushing / Cleaning Hot Water Heater Help Needed Cuse Home Repair 38 December 1st 03 02:01 AM


All times are GMT +1. The time now is 11:51 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"