Some of the air duct from the furnace to the registers are several shorter
ducts joint together. A while ago I found some of those joints failed and
separated in the crawlspace. The ducts look to be 8 to 12 inches in
diameter, and they want to pull away from each other at the joints, perhaps
the ducts were taut when installed. I duct taped them back. Although they
hold, they seem to be leaking air.

What is the best way to seal the joints?


  #2   Report Post  
peter
 
Posts: n/a
Default

I went into the crawlspace to investigate. Turns out the leaks are coming
out of the metal ducts' Y joints.

Here are some photos to illustrate:
http://www.smugmug.com/gallery/849974

I did not take photos of all the suspected leaks.

Although it may seem that the gap is small, but a lot of air is coming out.
What is the proper way to seal those joints? Some sort of sealant? I don't
want to use duct tape because they become dry and brittle after a few years
and then lose its effectiveness.


  #3   Report Post  
Ken
 
Posts: n/a
Default

peter wrote:
I went into the crawlspace to investigate. Turns out the leaks are coming
out of the metal ducts' Y joints.

Here are some photos to illustrate:
http://www.smugmug.com/gallery/849974

I did not take photos of all the suspected leaks.

Although it may seem that the gap is small, but a lot of air is coming out.
What is the proper way to seal those joints? Some sort of sealant? I don't
want to use duct tape because they become dry and brittle after a few years
and then lose its effectiveness.



Have you tried the "Metalized duct tape?" There is one not made of
cloth and it lasts a LONG time. Home Depot and other such stores have it.
  #4   Report Post  
Amun
 
Posts: n/a
Default


"peter" wrote in message
news:CDy%e.2738$kl3.322@trnddc08...
Some of the air duct from the furnace to the registers are several shorter
ducts joint together. A while ago I found some of those joints failed and
separated in the crawlspace. The ducts look to be 8 to 12 inches in
diameter, and they want to pull away from each other at the joints,

perhaps
the ducts were taut when installed. I duct taped them back. Although they
hold, they seem to be leaking air.

What is the best way to seal the joints?



lots of options, but depends on the type of "hole"
Are you sure there isn't crimped pipe joints that came apart ?

Duct tape is easiest, and you can get different grades, some is garbage,
some will last years.
it is also available in either the cloth or metal types.

You can also buy what we call ductseal, a brick of caulking type compound
that you press in like play dough.
(electrical and refrigeration wholesalers always have it)

Or even pop rivet another piece of metal over the hole.

Even just regular silicone caulking may work.

AMUN


  #5   Report Post  
DanG
 
Posts: n/a
Default

I would add hex drive, sharp tipped sheet metal screws - three per
joint. Gray cloth duck tape (original name) was never meant for
HVAC install. You need real metal duct tape. Example:
http://www.pplmotorhomes.com/parts/caulks-sealants/388521.htm

After screwing and taping you can also apply duct sealant. Here
is one we use:
http://www.fosterproducts.com/Images/childers_tds/cp-10-11.pdf
It is quite easy to apply with a throw away paint brush. If the
holes or gaps are huge, add fiberglass reinforcing mesh.


(top posted for your convenience)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Keep the whole world singing . . . .
DanG (remove the sevens)




"peter" wrote in message
news:CDy%e.2738$kl3.322@trnddc08...
Some of the air duct from the furnace to the registers are
several shorter ducts joint together. A while ago I found some
of those joints failed and separated in the crawlspace. The
ducts look to be 8 to 12 inches in diameter, and they want to
pull away from each other at the joints, perhaps the ducts were
taut when installed. I duct taped them back. Although they hold,
they seem to be leaking air.

What is the best way to seal the joints?





  #6   Report Post  
Bill Gill
 
Posts: n/a
Default

peter wrote:
Some of the air duct from the furnace to the registers are several shorter
ducts joint together. A while ago I found some of those joints failed and
separated in the crawlspace. The ducts look to be 8 to 12 inches in
diameter, and they want to pull away from each other at the joints, perhaps
the ducts were taut when installed. I duct taped them back. Although they
hold, they seem to be leaking air.

What is the best way to seal the joints?


I am in process of getting all new ducts. The company
that is doing the job puts three screws in each joint,
then brushes on a permanent duct seal over the joint.
They say it should last forever.

Of course I don't expect it will last a hundred years,
but then I don't expect to be worrying about it in a
hundred years.

Bill Gill
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Wood Burner with back boiler - heating installation questions Peter Sheppard UK diy 3 September 20th 05 07:29 PM
FF/FS: Hot water cylinder+immersion, heating pump, 7-day heating controller Jonathan Larmour UK diy 18 August 22nd 05 03:05 PM
Heating design diagram (preliminary) John Aston UK diy 55 December 10th 04 08:31 PM
Heating and hot water failure Alex UK diy 3 September 12th 04 09:28 PM
Noisy new boiler when heating water only David Hearn UK diy 8 May 20th 04 07:44 PM


All times are GMT +1. The time now is 01:04 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"