  #1   Report Post  
flumiani
 
Posts: n/a
Default Foundation Mount Central AC Unit

I just got a central air unit installed in a new construction house.
The unit is mounted on the foundation wall on steel "L" brackets just below
brick level.
When the unit is operating outside it doesn't seem very loud but inside I
seem to be getting lots of low level vibration (even on the 2nd floor above
the outside unit!)
I've heard suggestions of rubber spacers between the unit and the brackets,
a rubber gasket between the bracket and the foundation, an extention on the
bracket to a triangle shape instead of the "L" etc.
Is any of this worth trying or do I really need to remount it on the ground?

The only issue with the ground mount is that my soil grading hasn't been
done yet so I would need to wait.
I also think I would need to go maybe 4 patio stones thick to get to the
same height as it is now from where I anticipate the fill level will be.
Any problem with that or is making a box filled with crushed stone topped
with one patio stone perhaps a better base than stacking patio stones?



  #2   Report Post  
lp13-30
 
Posts: n/a
Default

I have only seen a/c units mounted like yours while visiting in upstate
NY. I assume it is for snow, which is not too much of a problem here in
south Texas. However, if you are paying for a new house, you are
entitled to have it fixed right. Putting the unit on patio blocks,
crushed stone or whatever, is not right. Vibration noises inside are not
right either. Insist that the builder get the A/C contractor make it to
your satisfaction, period.

  #3   Report Post  
SQLit
 
Posts: n/a
Default


"flumiani" wrote in message
. ..
I just got a central air unit installed in a new construction house.
The unit is mounted on the foundation wall on steel "L" brackets just

below
brick level.
When the unit is operating outside it doesn't seem very loud but inside I
seem to be getting lots of low level vibration (even on the 2nd floor

above
the outside unit!)
I've heard suggestions of rubber spacers between the unit and the

brackets,
a rubber gasket between the bracket and the foundation, an extention on

the
bracket to a triangle shape instead of the "L" etc.
Is any of this worth trying or do I really need to remount it on the

ground?

The only issue with the ground mount is that my soil grading hasn't been
done yet so I would need to wait.
I also think I would need to go maybe 4 patio stones thick to get to the
same height as it is now from where I anticipate the fill level will be.
Any problem with that or is making a box filled with crushed stone topped
with one patio stone perhaps a better base than stacking patio stones?


Send pictures of the installation. The way you describe this can not
possibly be correct.
I know of no residential condenser that is designed with clearances that
close. Most require a 2 foot minimum clearance.



  #4   Report Post  
Joseph Meehan
 
Posts: n/a
Default

flumiani wrote:
I just got a central air unit installed in a new construction house.
The unit is mounted on the foundation wall on steel "L" brackets just
below brick level.
When the unit is operating outside it doesn't seem very loud but
inside I seem to be getting lots of low level vibration (even on the
2nd floor above the outside unit!)
I've heard suggestions of rubber spacers between the unit and the
brackets, a rubber gasket between the bracket and the foundation, an
extention on the bracket to a triangle shape instead of the "L" etc.
Is any of this worth trying or do I really need to remount it on the
ground?


I have a like setup. I find that occasionally vibration has caused the
unit to move just enough that it is not really evenly set on the brackets
and needs to be moved maybe an inch. When it is solid on the brackets, it
is quiet.


The only issue with the ground mount is that my soil grading hasn't
been done yet so I would need to wait.
I also think I would need to go maybe 4 patio stones thick to get to
the same height as it is now from where I anticipate the fill level
will be. Any problem with that or is making a box filled with crushed
stone topped with one patio stone perhaps a better base than stacking
patio stones?


--
Joseph Meehan

Dia duit


  #5   Report Post  
flumiani
 
Posts: n/a
Default

I have a like setup. I find that occasionally vibration has caused the
unit to move just enough that it is not really evenly set on the brackets
and needs to be moved maybe an inch. When it is solid on the brackets, it
is quiet.


I double checked and it seems that mine is actually bolted to the brackets.
I'm assuming that it is centered.

Appreciate the reply.




  #6   Report Post  
flumiani
 
Posts: n/a
Default

I have only seen a/c units mounted like yours while visiting in upstate
NY. I assume it is for snow, which is not too much of a problem here in
south Texas. However, if you are paying for a new house, you are
entitled to have it fixed right. Putting the unit on patio blocks,
crushed stone or whatever, is not right. Vibration noises inside are not
right either. Insist that the builder get the A/C contractor make it to
your satisfaction, period.


I live up North yes, and hadn't really considered snow as the reason for the
foundation wall mount.
I believe the biggest convenience of the brackets is that you don't have to
worry about the backfill settlement around new construction since it is
right on the wall.
Unfortunately that is causing my vibration issue.

The A/C installation was done with a seperate contractor from my builder.
They visited today, insisted the wall installation was done right and that
the unit was functioning normally and that the best thing to do would be to
get it off the wall and onto the ground (at my further expense of course).


  #7   Report Post  
flumiani
 
Posts: n/a
Default

Send pictures of the installation. The way you describe this can not
possibly be correct.
I know of no residential condenser that is designed with clearances that
close. Most require a 2 foot minimum clearance.


I don't have access to a camera at the moment unfortunately so I'll explain
as best I can...
The L brackets have one plane facing downwards attached to the foundation
wall and another running parallel to the ground.
The unit sits on the backside/end of the L furthest away from the house,
likely 2 feet clear of the wall as you mention.
It is bolted directly into the brackets and the brackets are bolted right
into my concrete foundation wall, right below where the brick line is.

\ [ ]
\ (brick) [ A/C ]
\ [ unit ]
| ___________________
| |
| | L bracket
| |
| ---- concrete foundation wall


  #8   Report Post  
George E. Cawthon
 
Posts: n/a
Default

flumiani wrote:
I just got a central air unit installed in a new construction house.
The unit is mounted on the foundation wall on steel "L" brackets just below
brick level.
When the unit is operating outside it doesn't seem very loud but inside I
seem to be getting lots of low level vibration (even on the 2nd floor above
the outside unit!)
I've heard suggestions of rubber spacers between the unit and the brackets,
a rubber gasket between the bracket and the foundation, an extention on the
bracket to a triangle shape instead of the "L" etc.
Is any of this worth trying or do I really need to remount it on the ground?

The only issue with the ground mount is that my soil grading hasn't been
done yet so I would need to wait.
I also think I would need to go maybe 4 patio stones thick to get to the
same height as it is now from where I anticipate the fill level will be.
Any problem with that or is making a box filled with crushed stone topped
with one patio stone perhaps a better base than stacking patio stones?




First question is, did you check the hoses to make
sure they were insulated where they run into the
house?

Second, get the damn thing off the wall. When you
get the soil graded right, make a form for a
concrete base for the unit to set on and use ready
mix bags. Depending on weight of the unit, it
should be 3" or so bigger than the base and at
least 4-6" thick. Shim between the base and unit
with redwood or cedar to level if you need extra
height or the concrete base shifts. Mine base
hasn't moved in 25 years and we have lots of
freeze thaw. Then the soil will dampen any
vibration and the only parts attached to the house
are the hoses and electric wires.
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Central air help [email protected] Home Ownership 0 February 16th 05 05:59 AM
Need help with HVAC problem ClimateMaster Geo/Trane Air Handler KissHanksAss Home Repair 9 January 28th 05 03:39 AM
Hunter ceiling fan replacement switch -- do I snip wires and stab into new unit? Dolchas Home Repair 1 September 26th 04 07:48 PM
Installing humidistat on Intertherm Central A/C unit HvacTech2 Home Repair 10 July 6th 04 11:42 AM
DIY - adding central air calhoun Home Repair 11 June 14th 04 01:01 PM


All times are GMT +1. The time now is 10:01 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"