Default Proper way to tap into a gas line

What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.

  #2   Report Post  
 
Posts: n/a
Default


wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.


What kind of gas line? LPG? NG?

First, run a proper gas diametric, using the right charts for the type of
pipe you will use, and the pipe you have.
Make sure you have the total BTU of the grill, as this will determine into
the factor of the line size.
Once you have done that, taking the distance, BTU, line type into
consideration and sized your line correctly,
then, after determining where you are going to tap into the line, and
upsizing the feed to that point if needed, put you a T in, and as soon as
you come off it find a good place to put your union if needed, and a 1.4
turn gas valve. Feed your line to your grille, and if you plan on buring the
line, insure that you have the depth deep enough per your local code. Insure
that if the lines buried, you have protected the pipe properly and then,
when you turn up the line to your grill, if it was me, I would put a
secondary valve as before, another union if needed AND a secondary regulator
as many times it is the code to have one at the appliance. If its not
needed, I would still do it in the rare case that your main regulator would
fail, OR if you have a 2psi system it will be needed anyway. This is just
insurance to prevent a flare up should you have a main failure....it can and
does happen, altho it is very rare.

Main thing is to do it right. Protect yourself and your family, friends and
neighbors. Nothing wrong with doing it yourself, but follow any codes, pull
any permits and have it inspected should your area demand it by code. If it
does, also please take the time to see if you will need to get a licenced
pipefitter (read, NOT a plumber) to do the work.

  #3   Report Post  
toller
 
Posts: n/a
Default


wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.

Just want to warn you that I have put two iron pipes out to my gas grill,
and they have rusted way in about 2 years. I use propane now.
However one of these days I am putting in K copper, which is acceptable
here.


  #4   Report Post  
Art Todesco
 
Posts: n/a
Default

I've had copper on mine for 30 years and no problems.

toller wrote:

wrote in message
oups.com...

What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.


Just want to warn you that I have put two iron pipes out to my gas grill,
and they have rusted way in about 2 years. I use propane now.
However one of these days I am putting in K copper, which is acceptable
here.


  #5   Report Post  
Master
 
Posts: n/a
Default

Whatever you use make sure you always use a match to test for leaks....

wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.





  #6   Report Post  
Edwin Pawlowski
 
Posts: n/a
Default


" wrote in
message

Much god advice snipped.

Main thing is to do it right. Protect yourself and your family, friends
and
neighbors. Nothing wrong with doing it yourself, but follow any codes,
pull
any permits and have it inspected should your area demand it by code. If
it
does, also please take the time to see if you will need to get a licenced
pipefitter (read, NOT a plumber) to do the work.


The grill will also have to be taken off the wheels and bolted down
permanently.


  #7   Report Post  
TURTLE
 
Posts: n/a
Default


"Master" wrote in message
news:xiV7e.16128$Xm3.113@trndny01...
Whatever you use make sure you always use a match to test for leaks....


This is Turtle.

there is a high tech name for this device and it is a Coon Ass Gas Detector.

TURTLE


  #8   Report Post  
TURTLE
 
Posts: n/a
Default


wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.


This is Turtle

Here is a help page you can get help and tippes and also a useage chart at the
bottom of the page for what size pipe for what BTU you need and what each
appliance will burn.

http://www.metrokc.gov./health/plumbing/gaspiping.htm

TURTLE


  #9   Report Post  
 
Posts: n/a
Default


TURTLE wrote:
wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a

line
out to my deck for my grill. I have access to all the gas lines

around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on

the
deck is necessary.


This is Turtle

Here is a help page you can get help and tippes and also a useage

chart at the
bottom of the page for what size pipe for what BTU you need and what

each
appliance will burn.

http://www.metrokc.gov./health/plumbing/gaspiping.htm


thanks Turtle!

  #10   Report Post  
Stormin Mormon
 
Posts: n/a
Default

When I worked for another fellow, we used to shut off the gas. Carefully lay
out the job. Pick a section of pipe, and cut it in half with a sawzall.
Wrench out both ends of the now sliced pipe, and start building from there.

--

Christopher A. Young
Learn more about Jesus
www.lds.org
www.mormons.com


wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.




  #11   Report Post  
toller
 
Posts: n/a
Default


wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.

Just want to warn you that I have put two iron pipes out to my gas grill,
and they have rusted way in about 2 years. I use propane now.
However one of these days I am putting in K copper, which is acceptable
here.


  #12   Report Post  
calhoun
 
Posts: n/a
Default


"toller" wrote in message
...

wrote in message
oups.com...
What is the proper way to tap into a gas line? I want to run a line
out to my deck for my grill. I have access to all the gas lines around
the furnace, etc.

I imagine that a shutoff valve at the split as well as a shutoff on the
deck is necessary.

Just want to warn you that I have put two iron pipes out to my gas grill,
and they have rusted way in about 2 years. I use propane now.
However one of these days I am putting in K copper, which is acceptable
here.


Why not just use TracPipe it will not rust and is much easier to install
than pipe or copper.


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
trenching and other uses of a high pressure washer Jer Home Repair 5 November 18th 04 08:59 PM
Phone Line Problem - Plea barry martin Home Repair 1 July 3rd 04 03:09 PM
Telephone Line Problems barry martin Home Repair 1 March 7th 04 03:00 AM
Raster problem (bright vertical line and raster pulls in horizontally) with 31" Sylvania Rob Myers Electronics Repair 2 February 29th 04 01:16 PM
Removing a Gas Line? Joseph Meehan Home Repair 3 July 15th 03 06:47 PM


All times are GMT +1. The time now is 09:11 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"