Default Drafts through central A/C vents? Covers?

Hi,

I have the typical square ceiling central a/c vents in my house.
This style:
http://www.thisoldhouse.com/toh/imag...entralair4.jpg

I close them in the winter of course, but yesterday noticed that they
are definitely still drafty. Besides those magnetic vent covers, which
I'm not sure will even fit or stick, is there a better way of
insulating these? I haven't seen any products out there at all, and am
thinking about just making something up if I can't find anything
decent. Any suggestions?

Thanks!

--Jim

  #2   Report Post  
Alan Sung
 
Posts: n/a
Default

"Jimbo" wrote in message
ups.com...
Hi,

I have the typical square ceiling central a/c vents in my house.
This style:
http://www.thisoldhouse.com/toh/imag...entralair4.jpg

I close them in the winter of course, but yesterday noticed that they
are definitely still drafty. Besides those magnetic vent covers, which
I'm not sure will even fit or stick, is there a better way of
insulating these? I haven't seen any products out there at all, and am
thinking about just making something up if I can't find anything
decent. Any suggestions?

Thanks!

--Jim


Take a look at http://epb1.lbl.gov/Publications/lbl-35445.pdf "New
Technologies for Residential HVAC Ducts" from Lawrence Berkeley Nat'l Lab,
page 10, Figure 1.

Your ducts may have the air leakage problem that they illustrate.

-al sung
Rapid Realm Technology, Inc.
Hopkinton, MA


  #3   Report Post  
Jimbo
 
Posts: n/a
Default

After a little more investigation...
As a reference, I have a split level home.

I notice that, along with the vents, the return ALSO is leaking a small
amount of cold air into my home, into my first floor level. These vents
are closest to the handler and return, and somewhat "below" them.

But interestingly, the upper level of my home, which has it's own
mostly seperate attic, has no drafty vents at all. These vents are
somewhat "above" the handler and return.

As was mentioned, sound like I could have an air leakage problem
somewhere in the venting or handler... Besides some obvious gaps in the
ducts, is there anything in particular I should look for in the system?
Thanks!

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Rayburn integrated into central heating David Cawkwell UK diy 2 February 8th 05 07:23 PM
Number of return vents vs. supply vents jeff Home Repair 6 November 9th 04 05:05 PM
Adding A/C Vents this way barry martin Home Repair 0 June 5th 04 05:36 PM
Damp patch around air vents in bedroom Nathan Critchlow-Watton UK diy 6 January 12th 04 08:09 PM
1989 Lennox Central Air Water Condensation and Shutdown? Joe Esposito Home Repair 15 August 8th 03 04:42 PM


All times are GMT +1. The time now is 02:50 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"