Hello group,

Anyone know how to adjust the static convergence on a Thomson 52RG75J (ICC9
chassis)?
Dynamic convergence is done with pots under the front facade, but I think
static convergence is normally done using a service mode in the remote
control. Is this correct?
I don't have an original remote control, so can't enter the service menu
(on orig. menu and + buttons simultaneously). Is there any key sequence that
can be used on a universal remote control to enter the service mode?

thanks
Dan


  #2   Report Post  
Art
 
Posts: n/a
Default

Static is normally relating to mechanical adjustments such as centering,
width, height, etc. Dynamic on all relatively new chasis is always done via
a technician setup menu.
"Dan Payne" wrote in message
. ..
Hello group,

Anyone know how to adjust the static convergence on a Thomson 52RG75J
(ICC9
chassis)?
Dynamic convergence is done with pots under the front facade, but I think
static convergence is normally done using a service mode in the remote
control. Is this correct?
I don't have an original remote control, so can't enter the service menu
(on orig. menu and + buttons simultaneously). Is there any key sequence
that
can be used on a universal remote control to enter the service mode?

thanks
Dan




  #3   Report Post  
Dan Payne
 
Posts: n/a
Default

Thanks, but the generalities I know already. I'm looking for the specifics
on this one. It's an old design rear screen projector, with potentiometers
for the dynamic convergence, and I can see on the schematic that the static
convergence levels (centering etc) are set by a DAC chip on the I2C bus.
Therfore I assume that setting is done by the remote control.
Dan

"Art" wrote in message
...
Static is normally relating to mechanical adjustments such as centering,
width, height, etc. Dynamic on all relatively new chasis is always done

via
a technician setup menu.
"Dan Payne" wrote in message
. ..
Hello group,

Anyone know how to adjust the static convergence on a Thomson 52RG75J
(ICC9
chassis)?
Dynamic convergence is done with pots under the front facade, but I

think
static convergence is normally done using a service mode in the remote
control. Is this correct?
I don't have an original remote control, so can't enter the service menu
(on orig. menu and + buttons simultaneously). Is there any key sequence
that
can be used on a universal remote control to enter the service mode?

thanks
Dan






Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Convergence on PTV-375 Mike Electronics Repair 3 December 15th 03 08:54 PM
Mits VS60601 convergence JURB6006 Electronics Repair 4 October 13th 03 05:22 PM
PTK195 convergence woes, intermittent of course JURB6006 Electronics Repair 0 July 24th 03 11:59 PM


All times are GMT +1. The time now is 07:18 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"