Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems.

Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
JKoning
 
Posts: n/a
Default Tek 7613

After sitting unused for quite a while, the traces of my Tek 7613 scope are
skewed.
AFAICS this is not a front panel adjustment, unless I'm blind. And, sorry,
no manual :-(
Anybody know where to find the "trace-rotation/trace-alignment" pot?

Thanks,
Jan.


  #2   Report Post  
Bob
 
Posts: n/a
Default Tek 7613

JKoning wrote:
After sitting unused for quite a while, the traces of my Tek 7613
scope are skewed.
AFAICS this is not a front panel adjustment, unless I'm blind. And,
sorry, no manual :-(
Anybody know where to find the "trace-rotation/trace-alignment" pot?

Thanks,
Jan.


It's been a long time since I worked on Tek scopes - if it's not on the
front panel, then it might have been located on the storage board; that
would be the large circuit board on the right side of the scope, next to the
CRT. Pop the covers and snoop around; as I recall, it was a two wire
connector (black and red wires) that went to the trace rotation coil.

Hope this helps,
Bob.


  #3   Report Post  
Jim Yanik
 
Posts: n/a
Default Tek 7613

"JKoning" wrote in
.nl:

After sitting unused for quite a while, the traces of my Tek 7613
scope are skewed.
AFAICS this is not a front panel adjustment, unless I'm blind. And,
sorry, no manual :-(
Anybody know where to find the "trace-rotation/trace-alignment" pot?

Thanks,
Jan.




On the right rear side of the scope,on the top,is a narrow PCB,that is the
Z-axis amp and related CRT (geom,astig,T-rot)adjustments.IIRC,the pot you
want is labelled.

--
Jim Yanik
jyanik-at-kua.net
  #4   Report Post  
Andy Cuffe
 
Posts: n/a
Default Tek 7613

On Fri, 16 Apr 2004 11:57:45 +0200, "JKoning"
wrote:

After sitting unused for quite a while, the traces of my Tek 7613 scope are
skewed.
AFAICS this is not a front panel adjustment, unless I'm blind. And, sorry,
no manual :-(
Anybody know where to find the "trace-rotation/trace-alignment" pot?

Thanks,
Jan.



My 7623 has the rotation adjustment located on top of the scope. It
was the only top access hole on the scope. These is definitely a
rotation adjustment somewhere.
Andy Cuffe

  #5   Report Post  
JKoning
 
Posts: n/a
Default Tek 7613

I have found the trace rotation pot on the Z-axis board.
Possibly the 7613 found it's successor in the 7623 because of the difficult
access of the relevant pot.
There's no cover hole to access T-rot.
But, it is labeled indeed... , P1170... like all the pot's on the Z-axis
board are numbered.

Anyway, traces are fine now, flat like the Dutch horizon :-)

Thanks everybody for helping out!

Rgds,
Jan.



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT +1. The time now is 09:50 PM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"