SkyDemon
 
Posts: n/a
Default dead channel on CRO

Hi, i have a Kikusui COS5020 oscilloscope and channel 1 on it doesnt work
(not getting any trace at all). Does anyone know where to get the
schematic/service manual for it? (I have found a paid site but ill try and
see if i can get it free first).

Also can anyone point me in the right direction where to look for the fault?
When no channel is selected there is a faint unfocused mark on the screen
which stays there when ch 1 is selected so this leads me to believe that
maybe there is something wrong with the input selection section.

Hope that made sense

Cheers


  #2   Report Post  
Jerry G.
 
Posts: n/a
Default dead channel on CRO

It is very common that in most scopes people blow the front end by injecting
too high a voltage, as like in TV sets or power supplies. The MosFets are
most likely blown.

--

Greetings,

Jerry Greenberg GLG Technologies GLG
=========================================
WebPage http://www.zoom-one.com
Electronics http://www.zoom-one.com/electron.htm
=========================================


"SkyDemon" wrote in message
...
Hi, i have a Kikusui COS5020 oscilloscope and channel 1 on it doesnt work
(not getting any trace at all). Does anyone know where to get the
schematic/service manual for it? (I have found a paid site but ill try and
see if i can get it free first).

Also can anyone point me in the right direction where to look for the fault?
When no channel is selected there is a faint unfocused mark on the screen
which stays there when ch 1 is selected so this leads me to believe that
maybe there is something wrong with the input selection section.

Hope that made sense

Cheers



  #3   Report Post  
Nigel Cook
 
Posts: n/a
Default dead channel on CRO


"SkyDemon" wrote in message
...
Hi, i have a Kikusui COS5020 oscilloscope and channel 1 on it doesnt work
(not getting any trace at all). Does anyone know where to get the
schematic/service manual for it? (I have found a paid site but ill try and
see if i can get it free first).

Also can anyone point me in the right direction where to look for the

fault?
When no channel is selected there is a faint unfocused mark on the screen
which stays there when ch 1 is selected so this leads me to believe that
maybe there is something wrong with the input selection section.

Hope that made sense

Cheers



Generally speaking the diagnostic problem with
scopes as far as X and Y amps is they have
to be DC coupled throughout. So anywhere in
the chain something failing and sending the
signal high or low will shift the o/p well off beam.
Other than i/p FET overdriven the other common
problem is one of the pair of push-pull output
drivers to the CRT plates having failed.

e-mail (removing .....) electronic hints and repair briefs , schematics/manuals list on
http://homepages.tcp.co.uk/~diverse

Nigel,Diverse Devices,Southampton,England




Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Dead true centerdrilling. Jim Sehr Metalworking 6 July 10th 04 04:06 PM
static on right channel of kenwood receiver Sofie Electronics Repair 22 July 20th 03 03:18 AM
Static in left channel on vintage Marantz 2240 Receiver Beanie Electronics Repair 2 July 17th 03 12:19 AM


All times are GMT +1. The time now is 03:24 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 DIYbanter.
The comments are property of their posters.
 

About Us

"It's about DIY & home improvement"