Finding datasheet for a chip
I recently bought a heating pad which has a "feature" which shuts the
heat off after 2 hours. Virtually all pads seem to be made this way now, unfortunately. I would like to defeat this. I can probably jumper around the timer control portion of the switch to accomplish this, but I see in doing some searching that on at least one older model, some modification of the circuitry around the chip can accomplish this, too http://www.ralree.com/2007/12/13/dis...e-heating-pad/ Unfortunately, the circuit on that pad is not the same as mine, which is centered around an 8 pin chip marked "SEDS 13-000022 R1017A" I can't seem to find any data on this chip. Tried www.alldatasheet.com, no info that I could find. Anyone know where I might look, or have any other ideas for eliminating the timed off action? TIA Dan |
#2
Posted to sci.electronics.repair
|
|||
|
|||
Finding datasheet for a chip
On Mon, 06 Feb 2012 13:10:10 -0800, D wrote:
I recently bought a heating pad which has a "feature" which shuts the heat off after 2 hours. Virtually all pads seem to be made this way now, unfortunately. I would like to defeat this. I can probably jumper around the timer control portion of the switch to accomplish this, but I see in doing some searching that on at least one older model, some modification of the circuitry around the chip can accomplish this, too http://www.ralree.com/2007/12/13/dis...e-heating-pad/ Unfortunately, the circuit on that pad is not the same as mine, which is centered around an 8 pin chip marked "SEDS 13-000022 R1017A" I can't seem to find any data on this chip. Tried www.alldatasheet.com, no info that I could find. Anyone know where I might look, or have any other ideas for eliminating the timed off action? A 555 timer chip is only eight pins but so are many smaller microcontrollers. Can you take a picture of the circuit board (both sides, perhaps) and upload that to Flickr, ImageShack, or similar? That might help narrow down the choices somewhat. -- Rich Webb Norfolk, VA |
#3
Posted to sci.electronics.repair
|
|||
|
|||
Finding datasheet for a chip
"Rich Webb" wrote in message ... On Mon, 06 Feb 2012 13:10:10 -0800, D wrote: I recently bought a heating pad which has a "feature" which shuts the heat off after 2 hours. Virtually all pads seem to be made this way now, unfortunately. I would like to defeat this. I can probably jumper around the timer control portion of the switch to accomplish this, but I see in doing some searching that on at least one older model, some modification of the circuitry around the chip can accomplish this, too http://www.ralree.com/2007/12/13/dis...e-heating-pad/ Unfortunately, the circuit on that pad is not the same as mine, which is centered around an 8 pin chip marked "SEDS 13-000022 R1017A" I can't seem to find any data on this chip. Tried www.alldatasheet.com, no info that I could find. Anyone know where I might look, or have any other ideas for eliminating the timed off action? A 555 timer chip is only eight pins but so are many smaller microcontrollers. Can you take a picture of the circuit board (both sides, perhaps) and upload that to Flickr, ImageShack, or similar? That might help narrow down the choices somewhat. -- Rich Webb Norfolk, VA I suspect this is probably a Chinese in-house number. The chip could be anything and there is unlikely to be any data out there on it. Gareth. |
#4
Posted to sci.electronics.repair
|
|||
|
|||
Finding datasheet for a chip
On Mon, 6 Feb 2012 22:29:52 -0000, "Gareth Magennis"
wrote: "Rich Webb" wrote in message .. . On Mon, 06 Feb 2012 13:10:10 -0800, D wrote: I recently bought a heating pad which has a "feature" which shuts the heat off after 2 hours. Virtually all pads seem to be made this way now, unfortunately. I would like to defeat this. I can probably jumper around the timer control portion of the switch to accomplish this, but I see in doing some searching that on at least one older model, some modification of the circuitry around the chip can accomplish this, too http://www.ralree.com/2007/12/13/dis...e-heating-pad/ Unfortunately, the circuit on that pad is not the same as mine, which is centered around an 8 pin chip marked "SEDS 13-000022 R1017A" I can't seem to find any data on this chip. Tried www.alldatasheet.com, no info that I could find. Anyone know where I might look, or have any other ideas for eliminating the timed off action? A 555 timer chip is only eight pins but so are many smaller microcontrollers. Can you take a picture of the circuit board (both sides, perhaps) and upload that to Flickr, ImageShack, or similar? That might help narrow down the choices somewhat. -- Rich Webb Norfolk, VA I suspect this is probably a Chinese in-house number. The chip could be anything and there is unlikely to be any data out there on it. True but it's most likely going to be a counter like the other examples or, perhaps, something more modern like the aforementioned uC with an internal RC oscillator. Could be a 4-banger, even. But looking at where it is in the layout can give some clues to getting the OP a way to accomplish his intent. -- Rich Webb Norfolk, VA |
#5
Posted to sci.electronics.repair
|
|||
|
|||
Finding datasheet for a chip
On 2/6/2012 6:31 PM, Rich Webb wrote:
On Mon, 6 Feb 2012 22:29:52 -0000, "Gareth Magennis" wrote: "Rich wrote in message ... On Mon, 06 Feb 2012 13:10:10 -0800, wrote: I recently bought a heating pad which has a "feature" which shuts the heat off after 2 hours. Virtually all pads seem to be made this way now, unfortunately. I would like to defeat this. I can probably jumper around the timer control portion of the switch to accomplish this, but I see in doing some searching that on at least one older model, some modification of the circuitry around the chip can accomplish this, too http://www.ralree.com/2007/12/13/dis...e-heating-pad/ Unfortunately, the circuit on that pad is not the same as mine, which is centered around an 8 pin chip marked "SEDS 13-000022 R1017A" I can't seem to find any data on this chip. Tried www.alldatasheet.com, no info that I could find. Anyone know where I might look, or have any other ideas for eliminating the timed off action? A 555 timer chip is only eight pins but so are many smaller microcontrollers. Can you take a picture of the circuit board (both sides, perhaps) and upload that to Flickr, ImageShack, or similar? That might help narrow down the choices somewhat. -- Rich Webb Norfolk, VA I suspect this is probably a Chinese in-house number. The chip could be anything and there is unlikely to be any data out there on it. True but it's most likely going to be a counter like the other examples or, perhaps, something more modern like the aforementioned uC with an internal RC oscillator. Could be a 4-banger, even. But looking at where it is in the layout can give some clues to getting the OP a way to accomplish his intent. Thanks for the great replies. I'm not sure what the chip is, it's a SOP8 package, not a DIP like a 555 timer. Probably right, some proprietary design with little data available. One side of the line is switched via a small transistor, I disconnected the transistor & ran that side of the line directly. Heat levels are adjusted with the control switch on the other side of the line. So far so good. Also, the bloody thing is SUPPOSED to shut off at 2 hours, and it's barely making it past ONE. PITA. Dan |
#6
Posted to sci.electronics.repair
|
|||
|
|||
Finding datasheet for a chip
On 2/6/2012 11:27 PM, D wrote:
Thanks for the great replies. I'm not sure what the chip is, it's a SOP8 package, not a DIP like a 555 timer. Probably right, some proprietary design with little data available. One side of the line is switched via a small transistor, I disconnected the transistor & ran that side of the line directly. Heat levels are adjusted with the control switch on the other side of the line. So far so good. Also, the bloody thing is SUPPOSED to shut off at 2 hours, and it's barely making it past ONE. PITA. Dan I just re-read this & want to clarify that the pad IS now staying "on", after the mods. The message above may not have been clear. Thanks again. Dan |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Need help finding chip replacement... | Electronics Repair | |||
====Search for daTASHEET pioneer vsx 804 datasheet who can help me===== | Electronics Repair | |||
need datasheet | Electronics Repair | |||
Finding an IC chip | Electronics Repair | |||
Advice on how locating ( Chip FA4111 & chip M52722P) in the UK ? (for a vgood 21" monitor) | Electronics |