Home |
Search |
Today's Posts |
|
Electronics Repair (sci.electronics.repair) Discussion of repairing electronic equipment. Topics include requests for assistance, where to obtain servicing information and parts, techniques for diagnosis and repair, and annecdotes about success, failures and problems. |
Reply |
|
LinkBack | Thread Tools | Display Modes |
#1
Posted to sci.electronics.repair
|
|||
|
|||
Sony CD KSS 213E on an HCD NE3
"No Disc" - how I hate lying computers, "no data" - fair enough.
Dull red laser spot, focus and sledge operate correctly, spins up, until stopping after third attempt. Cleaned lens, and internal cover glass. Good cap ESR, both ribons check continuity ok. Tried adjusting power pot a bit but no change. Pushing the sledge cog around either way , the servo will return it, so focus presumably ok. Sometimes it will sit with "reading" in the display permanently and disc spinning almost top speed until switched off. Where to go next? I've another (salvaged) KSS 213E, unkown condition , will try replacing but I suspect something more downstream. |
#2
Posted to sci.electronics.repair
|
|||
|
|||
Sony CD KSS 213E on an HCD NE3
"N_Cook" wrote in message ... "No Disc" - how I hate lying computers, "no data" - fair enough. Dull red laser spot, focus and sledge operate correctly, spins up, until stopping after third attempt. Cleaned lens, and internal cover glass. Good cap ESR, both ribons check continuity ok. Tried adjusting power pot a bit but no change. Pushing the sledge cog around either way , the servo will return it, so focus presumably ok. Sometimes it will sit with "reading" in the display permanently and disc spinning almost top speed until switched off. Where to go next? I've another (salvaged) KSS 213E, unkown condition , will try replacing but I suspect something more downstream. http://cpc.farnell.com/_/kss213e/aiw...5?Ntt=KSS+213E Highly likely to solve the problem. If not, you know for a fact it is not the pickup, and you now have a spare pickup. Unless you really want to spend hours under the hood instead ...... |
#3
Posted to sci.electronics.repair
|
|||
|
|||
Sony CD KSS 213E on an HCD NE3
"N_Cook" wrote in message
... "No Disc" - how I hate lying computers, "no data" - fair enough. Dull red laser spot, focus and sledge operate correctly, spins up, until stopping after third attempt. Cleaned lens, and internal cover glass. Good cap ESR, both ribons check continuity ok. Tried adjusting power pot a bit but no change. Pushing the sledge cog around either way , the servo will return it, so focus presumably ok. Sometimes it will sit with "reading" in the display permanently and disc spinning almost top speed until switched off. Where to go next? I've another (salvaged) KSS 213E, unkown condition , will try replacing but I suspect something more downstream. I replace lots of KSS-213's and their flex cables on later model Sony's. Mark Z. |
#4
Posted to sci.electronics.repair
|
|||
|
|||
Sony CD KSS 213E on an HCD NE3
Mark Zacharias wrote in message
... "N_Cook" wrote in message ... "No Disc" - how I hate lying computers, "no data" - fair enough. Dull red laser spot, focus and sledge operate correctly, spins up, until stopping after third attempt. Cleaned lens, and internal cover glass. Good cap ESR, both ribons check continuity ok. Tried adjusting power pot a bit but no change. Pushing the sledge cog around either way , the servo will return it, so focus presumably ok. Sometimes it will sit with "reading" in the display permanently and disc spinning almost top speed until switched off. Where to go next? I've another (salvaged) KSS 213E, unkown condition , will try replacing but I suspect something more downstream. I replace lots of KSS-213's and their flex cables on later model Sony's. Mark Z. Is that the phenolic/kaptan ribbons or the plasticated ribbon that flexes on sled movement. I'd noticed the little pcb with the power pot was loose and could move around so perhaps straining the otherwise non-flexing flexible ribbon up to focus coils and laser. ? I did not expect that, slid out slideway rod and swapped KSS 213 and the thing worked without hickups. I assume that there was enough operation to set the focus coils and sled to zero-in on track 0 but not enough for data readout. |
#5
Posted to sci.electronics.repair
|
|||
|
|||
Sony CD KSS 213E on an HCD NE3
"N_Cook" wrote in message
... Mark Zacharias wrote in message ... "N_Cook" wrote in message ... "No Disc" - how I hate lying computers, "no data" - fair enough. Dull red laser spot, focus and sledge operate correctly, spins up, until stopping after third attempt. Cleaned lens, and internal cover glass. Good cap ESR, both ribons check continuity ok. Tried adjusting power pot a bit but no change. Pushing the sledge cog around either way , the servo will return it, so focus presumably ok. Sometimes it will sit with "reading" in the display permanently and disc spinning almost top speed until switched off. Where to go next? I've another (salvaged) KSS 213E, unkown condition , will try replacing but I suspect something more downstream. I replace lots of KSS-213's and their flex cables on later model Sony's. Mark Z. Is that the phenolic/kaptan ribbons or the plasticated ribbon that flexes on sled movement. Yes, that's the one. I'd noticed the little pcb with the power pot was loose and could move around so perhaps straining the otherwise non-flexing flexible ribbon up to focus coils and laser. ? I don't think it's the yellow / brown flat wire to the coils and laser diode - I just think it's crap semiconductor material, either the laser diode itself, or the diode pack on the output side. I did not expect that, slid out slideway rod and swapped KSS 213 and the thing worked without hickups. I assume that there was enough operation to set the focus coils and sled to zero-in on track 0 but not enough for data readout. Looks like you've got it handled anyway... Mark Z. |
#6
Posted to sci.electronics.repair
|
|||
|
|||
Sony CD KSS 213E on an HCD NE3
Mark Zacharias wrote in message
... "N_Cook" wrote in message ... Mark Zacharias wrote in message ... "N_Cook" wrote in message ... "No Disc" - how I hate lying computers, "no data" - fair enough. Dull red laser spot, focus and sledge operate correctly, spins up, until stopping after third attempt. Cleaned lens, and internal cover glass. Good cap ESR, both ribons check continuity ok. Tried adjusting power pot a bit but no change. Pushing the sledge cog around either way , the servo will return it, so focus presumably ok. Sometimes it will sit with "reading" in the display permanently and disc spinning almost top speed until switched off. Where to go next? I've another (salvaged) KSS 213E, unkown condition , will try replacing but I suspect something more downstream. I replace lots of KSS-213's and their flex cables on later model Sony's. Mark Z. Is that the phenolic/kaptan ribbons or the plasticated ribbon that flexes on sled movement. Yes, that's the one. I'd noticed the little pcb with the power pot was loose and could move around so perhaps straining the otherwise non-flexing flexible ribbon up to focus coils and laser. ? I don't think it's the yellow / brown flat wire to the coils and laser diode - I just think it's crap semiconductor material, either the laser diode itself, or the diode pack on the output side. I did not expect that, slid out slideway rod and swapped KSS 213 and the thing worked without hickups. I assume that there was enough operation to set the focus coils and sled to zero-in on track 0 but not enough for data readout. Looks like you've got it handled anyway... Mark Z. It was PbF solder for this one although 2004, could be something to do with it |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Sony gurus?......Sony 65xbr10w circa 2000/1 & 720p'support'........... | Electronics Repair | |||
sony ericsson GOLD EDITION..An exclusive for sony lovers | Electronics Repair | |||
SONY DVD player No power. Seems common across many Sony DVD's | Electronics Repair | |||
Sony G410R Monitor problem (and bad Sony support) | Electronics Repair |