View Single Post
  #3   Report Post  
Posted to sci.electronics.repair
Mark Zacharias[_2_] Mark Zacharias[_2_] is offline
external usenet poster
 
Posts: 115
Default Sony CD KSS 213E on an HCD NE3

"N_Cook" wrote in message
...
"No Disc" - how I hate lying computers, "no data" - fair enough.
Dull red laser spot, focus and sledge operate correctly, spins up, until
stopping after third attempt. Cleaned lens, and internal cover glass. Good
cap ESR, both ribons check continuity ok.
Tried adjusting power pot a bit but no change.
Pushing the sledge cog around either way , the servo will return it, so
focus presumably ok.
Sometimes it will sit with "reading" in the display permanently and disc
spinning almost top speed until switched off. Where to go next? I've
another
(salvaged) KSS 213E, unkown condition , will try replacing but I suspect
something more downstream.



I replace lots of KSS-213's and their flex cables on later model Sony's.

Mark Z.