N_Cook N_Cook is offline
external usenet poster
 
Posts: 5,247
Default Sony CD KSS 213E on an HCD NE3

Mark Zacharias wrote in message
...
"N_Cook" wrote in message
...
"No Disc" - how I hate lying computers, "no data" - fair enough.
Dull red laser spot, focus and sledge operate correctly, spins up, until
stopping after third attempt. Cleaned lens, and internal cover glass.

Good
cap ESR, both ribons check continuity ok.
Tried adjusting power pot a bit but no change.
Pushing the sledge cog around either way , the servo will return it, so
focus presumably ok.
Sometimes it will sit with "reading" in the display permanently and disc
spinning almost top speed until switched off. Where to go next? I've
another
(salvaged) KSS 213E, unkown condition , will try replacing but I suspect
something more downstream.



I replace lots of KSS-213's and their flex cables on later model Sony's.

Mark Z.


Is that the phenolic/kaptan ribbons or the plasticated ribbon that flexes on
sled movement.
I'd noticed the little pcb with the power pot was loose and could move
around so perhaps straining the otherwise non-flexing flexible ribbon up to
focus coils and laser. ?

I did not expect that, slid out slideway rod and swapped KSS 213 and the
thing worked without hickups. I assume that there was enough operation to
set the focus coils and sled to zero-in on track 0 but not enough for data
readout.